HANNA HI93712-01 Photometer reagent, aluminum 100 times
Reagent name Aluminum, range 0.00 to 1.00 mg/L (as Al3 +), 100 times.
HANNA-
TONGAO TR-205H Total Chromium (Chromium Ion) Tester
$ 786.00 -
YUEFENG SZ81111 Chlorine dioxide analyzer, chlorine dioxide concentration analysis 0~ 5.0mg/L
$ 343.00 -
HANNA HI98494 multiparameter Water Quality Analyzer (12 parameters)
$ 4315.00 -
TONGAO TR-ZH heavy metals STIP-scan Total Chromium/Hexavalent Chromium/Copper/Nickel/Zinc/Iron
$ 3149.00 -
HANNA HI5222 Professional desktop acidity pH/mV-temperature Tester
$ 1442.00
Luminometer routine reagents are a range of reagents for measuring the concentration of different chemical substances, designed for a variety of analytical needs. These reagents are able to react with target chemicals in a photometer to provide accurate measurements. Different types of reagents are suitable for the determination of ammonia nitrogen, residual chlorine, total chlorine, copper, nitrite, manganese, aluminum, iodine, calcium hardness, magnesium hardness, iron, hexavalent chromium, nickel and nitrate and other chemical substances from low to high concentrations, and each reagent provides 100 tests (except for some models such as high concentration ammonia nitrogen reagents can reach 300 times). These reagents are widely used in water analysis and environmental monitoring to ensure accurate and reliable measurement of chemical concentrations in a wide range of liquid samples.
HI93712-01 is a pre-measured, high-quality reagent that allows users to achieve fast and accurate colorimetric measurements. These reagents are part of the method adapted from the aluminum method. The reaction between the reagent and the aluminum produces a red color in the sample. By adding a reagent to the sample, a reaction will occur, and a compatible photometer can be used to determine the concentration of the resulting color. Results will be presented in milligrams per liter (ppm) of aluminum. These reagents are designed for samples with an expected range of 0.00 to 1.00 mg/L aluminum.
Compatible photometers include:
HI83200
HI83205
HI83099
HI96712
Conventional reagents for photometers
| Model | name | range | frequency |
| HI93700-01 | Low concentration of ammonia nitrogen | 0.00~3.00 mg/L (as NH3-N) | 100 |
| HI93715-01 | Medium concentration of ammonia nitrogen | 0.00-10.00mg/L | 100 |
| HI93733-01 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 100 |
| HI93733-03 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 300 |
| HI93701-01 | Residual chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93711-01 | Total chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93702-01 | copper | 0.00~5.00 mg/L (as Cu) | 100 |
| HI93707-01 | Low concentration of nitrite | 0~600 μg/L (as NO2-N) | 100 |
| HI93708-01 | High concentration of nitrite | 0~150 mg/L (as NO2-) | 100 |
| HI93709-01 | manganese | 0.0~20.0 mg/L (as Mn) | 100 |
| HI93712-01 | aluminium | 0.00~1.00 mg/L (as Al3+) | 100 |
| HI93718-01 | iodine | 0.0~12.5 mg/L (as I2) | 100 |
| HI93719-01 | Magnesium hardness | 0.00~2.00 mg/L (as CaCO3) | 100 |
| HI93720-01 | Calcium hardness | 0.00~2.70 mg/L (as CaCO3) | 100 |
| HI93721-01 | iron | 0.00~5.00mg/L(ppm)Fe | 100 |
| HI93723-01 | Hexavalent chromium | 0~1000 μg/L (as Cr(VI)) | 100 |
| HI93726-01 | nickel | 0.00~7.00 g/L (as Ni) | 100 |
| HI93728-01 | nitrate | 0.0~30.0 mg/L (as NO3--N) | 100 |
HANNA HI93712-01 Photometer ReagentSpecifications
| LIST | VALUE |
|---|---|
| reagent name | aluminum |
| scope | 0.00~1.00 mg/L (as Al3+) |
| number of times | 100 times |
HANNA HI93712-01 Photometer Reagent Packing list
Reagent X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93712-01