HANNA HI93723-01 Photometer reagent, hexavalent chromium 100 times
The reagent name is hexavalent chromium, in the range of 0 to 1000 μg/L (as Cr (VI)), and the number of times is 100.
HANNA-
Qiwei Y-615 Portable Ozone Analyzer
$ 254.00 -
LEICI nitrate ion electrode calibrating solution, suitable for nitrate ion composite electrode
$ 106.00 -
LEICI DGB-403F Portable residual chlorine/total chlorine/chlorine dioxide Tester
$ 612.00 -
Bante903P-UK Portable multiparameter Water Quality Meter
$ 571.00 -
HANNA HI76407A/P special PTFE dissolved oxygen membrane
$ 214.00
Luminometer routine reagents are a range of reagents for measuring the concentration of different chemical substances, designed for a variety of analytical needs. These reagents are able to react with target chemicals in a photometer to provide accurate measurements. Different types of reagents are suitable for the determination of ammonia nitrogen, residual chlorine, total chlorine, copper, nitrite, manganese, aluminum, iodine, calcium hardness, magnesium hardness, iron, hexavalent chromium, nickel and nitrate and other chemical substances from low to high concentrations, and each reagent provides 100 tests (except for some models such as high concentration ammonia nitrogen reagents can reach 300 times). These reagents are widely used in water analysis and environmental monitoring to ensure accurate and reliable measurement of chemical concentrations in a wide range of liquid samples.
HI93723-01 is a pre-measured, high-quality reagent that allows users to achieve fast and accurate colorimetric measurements. This method is an adaptation of the diphenylcarbohydrazide method. The reaction between chromium VI and the reagent results in a purple color in the sample. By simply adding the reagent to the sample, a reaction will take place and the concentration of the resulting color can be determined using a compatible photometer. Results will be displayed in μg/L (ppb) chromium VI. These reagents are designed for samples with an expected range of 0 to 1000 μg/L chromium VI.
Compatible photometers include:
HI83099
HI83200
HI83205
HI83206
HI96723
Conventional reagents for photometers
| Model | name | range | frequency |
| HI93700-01 | Low concentration of ammonia nitrogen | 0.00~3.00 mg/L (as NH3-N) | 100 |
| HI93715-01 | Medium concentration of ammonia nitrogen | 0.00-10.00mg/L | 100 |
| HI93733-01 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 100 |
| HI93733-03 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 300 |
| HI93701-01 | Residual chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93711-01 | Total chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93702-01 | copper | 0.00~5.00 mg/L (as Cu) | 100 |
| HI93707-01 | Low concentration of nitrite | 0~600 μg/L (as NO2-N) | 100 |
| HI93708-01 | High concentration of nitrite | 0~150 mg/L (as NO2-) | 100 |
| HI93709-01 | manganese | 0.0~20.0 mg/L (as Mn) | 100 |
| HI93712-01 | aluminium | 0.00~1.00 mg/L (as Al3+) | 100 |
| HI93718-01 | iodine | 0.0~12.5 mg/L (as I2) | 100 |
| HI93719-01 | Magnesium hardness | 0.00~2.00 mg/L (as CaCO3) | 100 |
| HI93720-01 | Calcium hardness | 0.00~2.70 mg/L (as CaCO3) | 100 |
| HI93721-01 | iron | 0.00~5.00mg/L(ppm)Fe | 100 |
| HI93723-01 | Hexavalent chromium | 0~1000 μg/L (as Cr(VI)) | 100 |
| HI93726-01 | nickel | 0.00~7.00 g/L (as Ni) | 100 |
| HI93728-01 | nitrate | 0.0~30.0 mg/L (as NO3--N) | 100 |
HANNA HI93723-01 Photometer ReagentSpecifications
| LIST | VALUE |
|---|---|
| reagent name | hexavalent chromium |
| scope | 0~1000 μg/L (as Cr(VI)) |
| number of times | 100 times |
HANNA HI93723-01 Photometer Reagent Packing list
Reagent X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93723-01