HANNA HI93726-01 Photometer Nickel reagent 100 times
Reagent name Nickel, range 0.00 to 7.00 g/L (as Ni), 100 times.
HANNA-
QIWEI NS-1T desktop urea Detector measurement range 0-10mg/L
$ 300.00 -
JINGQI WD9103B Portable Water Quality Tester, Total Nitrogen
$ 1691.00 -
HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
$ 613.00 -
TONGAO TR-140H Portable Sulfide Tester 0-4mg/L
$ 792.00 -
YUEFENG SZ8119 Manganese analyzer, manganese content analyzer 0~ 0.5mg/L
$ 345.00
Luminometer routine reagents are a range of reagents for measuring the concentration of different chemical substances, designed for a variety of analytical needs. These reagents are able to react with target chemicals in a photometer to provide accurate measurements. Different types of reagents are suitable for the determination of ammonia nitrogen, residual chlorine, total chlorine, copper, nitrite, manganese, aluminum, iodine, calcium hardness, magnesium hardness, iron, hexavalent chromium, nickel and nitrate and other chemical substances from low to high concentrations, and each reagent provides 100 tests (except for some models such as high concentration ammonia nitrogen reagents can reach 300 times). These reagents are widely used in water analysis and environmental monitoring to ensure accurate and reliable measurement of chemical concentrations in a wide range of liquid samples.
HI93726-01 is a pre-measured, high-quality reagent that allows users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the photometric method. The reaction between the nickel and the reagent results in a blue color in the sample. The reaction occurs by simply adding the reagent to the sample, and one of the Hanna-compatible benchtop or portable meters will determine the concentration from the resulting color. Results will be presented in milligrams per liter (ppm) nickel. These reagents are designed for samples with an expected range of 0.00 to 7.00 g/L (as nickel).
Conventional reagents for photometers
| Model | name | range | frequency |
| HI93700-01 | Low concentration of ammonia nitrogen | 0.00~3.00 mg/L (as NH3-N) | 100 |
| HI93715-01 | Medium concentration of ammonia nitrogen | 0.00-10.00mg/L | 100 |
| HI93733-01 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 100 |
| HI93733-03 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 300 |
| HI93701-01 | Residual chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93711-01 | Total chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93702-01 | copper | 0.00~5.00 mg/L (as Cu) | 100 |
| HI93707-01 | Low concentration of nitrite | 0~600 μg/L (as NO2-N) | 100 |
| HI93708-01 | High concentration of nitrite | 0~150 mg/L (as NO2-) | 100 |
| HI93709-01 | manganese | 0.0~20.0 mg/L (as Mn) | 100 |
| HI93712-01 | aluminium | 0.00~1.00 mg/L (as Al3+) | 100 |
| HI93718-01 | iodine | 0.0~12.5 mg/L (as I2) | 100 |
| HI93719-01 | Magnesium hardness | 0.00~2.00 mg/L (as CaCO3) | 100 |
| HI93720-01 | Calcium hardness | 0.00~2.70 mg/L (as CaCO3) | 100 |
| HI93721-01 | iron | 0.00~5.00mg/L(ppm)Fe | 100 |
| HI93723-01 | Hexavalent chromium | 0~1000 μg/L (as Cr(VI)) | 100 |
| HI93726-01 | nickel | 0.00~7.00 g/L (as Ni) | 100 |
| HI93728-01 | nitrate | 0.0~30.0 mg/L (as NO3--N) | 100 |
HANNA HI93726-01 PhotoMeter ReagentSpecifications
| LIST | VALUE |
|---|---|
| reagent name | nickel |
| scope | 0.00~7.00 g/L (as Ni) |
| number of times | 100 times |
HANNA HI93726-01 PhotoMeter Reagent Packing list
Reagent X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93726-01