YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002
Quantity range 0~100g, Repeatability Error +/- 0.0002g, Adjustment internal calibrated, Pan Size 0019 80mm, actual Graduation d0.1mg, Tare Range 0~100g, Linearity +/- 0.0005g, Stabilization time ≤ 6s, integration time 2/4/8s adjustable
YuePing-
Electronic Balance Tianma TD20K-1 20000g/1g
$ 176.00 -
JINGHAI JA4003N (internal calibration) Analytical balance 410g/1mg φ 110mm
$ 598.00 -
AB124C Electronic Balance Electronic Balance 120g/0.1mg
$ 985.00 -
HUAZHI PTQ-A + 50 PTQ Large Weighing Electronic Balance Maximum Weighing 50kg
$ 680.00 -
HUAZHI PTY-4202/5202 Professional Precision Balance Maximum Weighing: 4200g/5200g
$ 1485.00
product description
The liquid/solid specific gravity balance is a new product developed on the basis of the FA/JA series Electronic Analytical Balance. It is also an intelligent balance composed of a high-stability electromagnetic balance sensor and a single-chip microcomputer. It retains all the functions of an analytical balance in addition to the function of measuring the specific gravity of liquids/solids. Yueping electronic specific gravity balance is accurate, fast and stable, easy to operate, and has complete functions. It is suitable for rapid determination of the quality and quantity of objects in industry, agriculture, commerce, schools, scientific research and other units.
Product parameters
| model: | FA1004J |
| Weighing range/g: | 0~100 |
| Actual scale division value/mg: | 0.1 |
| Tare range/g: | 0~100 |
| Repeatability Error (standard deviation)/g: | ±0.0002 |
| Linearity error/g: | ±0.0005 |
| Stabilization time/s: | ≤6 |
| Integration time (adjustable)/s: | 2/4/8 |
| Pan diameter/mm: | Φ80 |
| Dimensions/mm: | 350×215×340 |
| Net weight/kg: | 6.8 |
| power supply: | 110V—220V, 50Hz—60Hz, 5.0V—3.0A, 0.5A |
| Power/VA: | 15 |
| Self-calibration weight value/g: | 100 |
| Very good warm-up time/min: | 180 |
Analytical Balance Calibration
In order to obtain accurate weighing results, calibration is required to accommodate the local acceleration of gravity.
When calibration is required:
• Before using the balance for the first time
• Weighing work is carried out regularly
• After changing placement
Method for Calibration of Electron Density Analytical Balance
1. Prepare calibration weights for calibration.
2. Make the weighing pan empty, press the "calibration" key until the word "CAL-200" appears on the display screen, and then release the key. When the word "CAL-200" flashes on the display screen, put the calibration weight code (try to put it in the center of the weighing pan), and the balance is calibrated. When the display shows "200.0000", remove the weight on the weighing pan. When "0.0000g" appears on the display screen, the calibration of the balance is over, and the balance automatically returns to the weighing working state.



Electronic density analysis balance operation: weighing, taring, adding, reading deviation
Weigh the
above modes after the user selects them (this balance has a memory function, all selected modes can be used for weighing after the power is turned off and will not be lost), press the <tare> key, after the display is zero, set The object to be weighed is on the weighing pan, and when the balance is stable, that is, after the "0" sign on the left of the display screen goes out, the displayed value is the mass value of the object to be weighed.
Tare and
reset the container on the weighing pan, the balance will display the weight of the container, press the <Tare> key, it will display zero, that is, tare weight. Place the object to be weighed in the container again, and the net weight of the object to be weighed will be displayed at this time.
Accumulative weighing
uses tare weighing method, put the objects to be weighed on the weighing pan one by one, and then remove all objects to be weighed one by one, and finally remove all the objects to be weighed. At this time, the absolute value of the displayed number is total mass value.
Put the added object
in the "integral" mode, place the container on the weighing pan, and go to tare. Add the weighing object (liquid or loose object) into the container step by step, and get continuous reading value quickly. When the added object reaches the required weighing value and the "0" sign on the far left of the display goes out, the value displayed at this time is the weighing value required by the user. When adding mixtures, the net mass of each substance may be determined by the tare method.
To read the deviation
, put the standard weight (or sample) on the weighing pan, remove the tare weight, then remove the standard weight, display its negative value, and then place the weighing object on the weighing pan, assuming that the weighing object is heavier than the standard weight or Light, positive or negative deviation values are displayed accordingly.
Lower the scale
and unscrew the screws on the lower cover at the bottom to expose the hooks. Place the balance on the workbench with the hole, adjust the level, and calibrate the balance, and then you can use the hook to hang objects and weigh.
The same series of electronic density analysis balance models
| model | FA1004J | FA1104J | FA1604J | FA2004J | FA2104J |
| accuracy level | |||||
| Weighing range/g | 0~100 | 0~110 | 0~160 | 0~200 | 0~210 |
| Actual scale division value/mg | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| Tare Range/g | 0~100 | 0~200 | 0~210 | 0~200 | 0~210 |
| Repeatability Error (standard deviation)/g | ±0.0002 | ±0.0002 | ±0.0002 | ±0.0002 | ±0.0002 |
| Linear error/g | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 |
| Stabilization time/s | ≤6 | ≤6 | ≤8 | ≤8 | ≤8 |
| Integration time (adjustable)/s | 2/4/8 | 2/4/8 | 2.5/5/10 | 2.5/5/10 | 2.5/5/10 |
| Pan diameter/mm | Φ80 | ||||
| Dimensions/mm | 350×215×340 | ||||
| Net weight/kg | 6.8 | ||||
| power supply | 110V—220V, 50Hz—60Hz, 5.0V—3.0A, 0.5A | ||||
| Power/VA | 15 | ||||
| Self-calibration weight value/g | 100 | 100 | 160 | 200 | 200 |
| Very good boot warm-up time/min | 180 | 180 | 180 | 180 | 180 |
YuePing FA1004J Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Weighing range | 0~100g |
| Repeatability Error | ±0.0002g |
| Adjustment | Internal calibrated |
| Pan Size | Φ80mm |
| Power | 110V—220V、50Hz—60Hz、5.0V—3.0A、0.5A |
| Net Weight | 6800g |
| Dimensions | 350*215*340mm |
| Actual Graduation d | 0.1mg |
| Tare Range | 0~100g |
| Linearity | ±0.0005g |
| Stabilization time | ≤6s |
| integration time | 2/4/8S adjustable |
| Power | 15V.A |
| Test Weight | 100g |
| Warm-up time | 180min |
YuePing FA1004J Electronic Balance Packing list
Adapter x1, weight pliers x1, handkerchief x1, instruction manual x1, certificate x1, warranty card x1, weighing plate x1, test weight x1, brush x1, fixing bracket x1, thermometer x1, thermometer clip x1, measurement table x1, glassgraduates with scale x1, liquid components (double hook code, platinum wire, hammer measuring) x1, solid components (net basket) x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44343-2024
- ActiveJJF 1847-2020
- ActiveJJF 1940-2021
- ActiveJJF 1036-2022
- ActiveGB/T 26497-2022
- ActiveGB/T 33374-2016
- ActiveSN/T 4118-2015
- ActiveHG/T 5375-2018
- ActiveHG/T 5164-2017
- AbolishGB/T 5211.3-1985
- AbolishGB/T 1714-1979
- ActiveHG/T 2758-1996
- ActiveFZ/T 50010.3-2011
- ActiveJB/T 7443-1994
- ActiveGB/T 26497-2011
- ActiveHG/T 3856-2006


FA1004J