      Home> Electronic Balance> YuePing> YuePing FA1004J Electronic Balance

      YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002

      Quantity range 0~100g, Repeatability Error +/- 0.0002g, Adjustment internal calibrated, Pan Size 0019 80mm, actual Graduation d0.1mg, Tare Range 0~100g, Linearity +/- 0.0005g, Stabilization time ≤ 6s, integration time 2/4/8s adjustable

      Brand
      SKU: NB000481
      China YuePing
      Model
      Stock
      Loading…
      Price
      $ 621.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • YuePing FA1004J Electronic BalanceOverview

        • Specifications
        • Comments
        • FAQs
        FA1004J
        Electronic Balance
        • YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002
        • YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002 Figure 1
        • YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002 Figure 2
        Quantity range 0~100g, Repeatability Error +/- 0.0002g, Adjustment internal calibrated, Pan Size 0019 80mm, actual Graduation d0.1mg, Tare Range 0~100g, Linearity +/- 0.0005g, Stabilization time ≤ 6s, integration time 2/4/8s adjustable

        product description

        The liquid/solid specific gravity balance is a new product developed on the basis of the FA/JA series Electronic Analytical Balance. It is also an intelligent balance composed of a high-stability electromagnetic balance sensor and a single-chip microcomputer. It retains all the functions of an analytical balance in addition to the function of measuring the specific gravity of liquids/solids. Yueping electronic specific gravity balance is accurate, fast and stable, easy to operate, and has complete functions. It is suitable for rapid determination of the quality and quantity of objects in industry, agriculture, commerce, schools, scientific research and other units.

        Product parameters

        model:FA1004J
        Weighing range/g:0~100
        Actual scale division value/mg:0.1
        Tare range/g:0~100
        Repeatability Error (standard deviation)/g:±0.0002
        Linearity error/g:±0.0005
        Stabilization time/s:≤6
        Integration time (adjustable)/s:2/4/8
        Pan diameter/mm:Φ80
        Dimensions/mm:350×215×340
        Net weight/kg:6.8
        power supply:110V—220V, 50Hz—60Hz, 5.0V—3.0A, 0.5A
        Power/VA:15
        Self-calibration weight value/g:100
        Very good warm-up time/min:180

        Analytical Balance Calibration

        In order to obtain accurate weighing results, calibration is required to accommodate the local acceleration of gravity.

        When calibration is required:

        • Before using the balance for the first time

        • Weighing work is carried out regularly

        • After changing placement

        Method for Calibration of Electron Density Analytical Balance

        1. Prepare calibration weights for calibration.

        2. Make the weighing pan empty, press the "calibration" key until the word "CAL-200" appears on the display screen, and then release the key. When the word "CAL-200" flashes on the display screen, put the calibration weight code (try to put it in the center of the weighing pan), and the balance is calibrated. When the display shows "200.0000", remove the weight on the weighing pan. When "0.0000g" appears on the display screen, the calibration of the balance is over, and the balance automatically returns to the weighing working state.


        Electronic density analysis balance operation: weighing, taring, adding, reading deviation

        Weigh the
            above modes after the user selects them (this balance has a memory function, all selected modes can be used for weighing after the power is turned off and will not be lost), press the <tare> key, after the display is zero, set The object to be weighed is on the weighing pan, and when the balance is stable, that is, after the "0" sign on the left of the display screen goes out, the displayed value is the mass value of the object to be weighed.

        Tare and
            reset the container on the weighing pan, the balance will display the weight of the container, press the <Tare> key, it will display zero, that is, tare weight. Place the object to be weighed in the container again, and the net weight of the object to be weighed will be displayed at this time.

        Accumulative weighing
            uses tare weighing method, put the objects to be weighed on the weighing pan one by one, and then remove all objects to be weighed one by one, and finally remove all the objects to be weighed. At this time, the absolute value of the displayed number is total mass value.

        Put the added object
            in the "integral" mode, place the container on the weighing pan, and go to tare. Add the weighing object (liquid or loose object) into the container step by step, and get continuous reading value quickly. When the added object reaches the required weighing value and the "0" sign on the far left of the display goes out, the value displayed at this time is the weighing value required by the user. When adding mixtures, the net mass of each substance may be determined by the tare method.

        To read the deviation 
        , put the standard weight (or sample) on the weighing pan, remove the tare weight, then remove the standard weight, display its negative value, and then place the weighing object on the weighing pan, assuming that the weighing object is heavier than the standard weight or Light, positive or negative deviation values are displayed accordingly.

        Lower the scale
        and unscrew the screws on the lower cover at the bottom to expose the hooks. Place the balance on the workbench with the hole, adjust the level, and calibrate the balance, and then you can use the hook to hang objects and weigh.

        The same series of electronic density analysis balance models

        modelFA1004JFA1104JFA1604JFA2004JFA2104J
        accuracy level1451553784753055160.gif1454328919477066587.gif1454328925826088469.gif1454328930250038832.gif1454328935140039124.gif
        Weighing range/g0~1000~1100~1600~2000~210
        Actual scale division value/mg0.10.10.10.10.1
        Tare Range/g0~1000~2000~2100~2000~210
        Repeatability Error (standard deviation)/g±0.0002±0.0002±0.0002±0.0002±0.0002
        Linear error/g±0.0005±0.0005±0.0005±0.0005±0.0005
        Stabilization time/s≤6≤6≤8≤8≤8
        Integration time (adjustable)/s2/4/82/4/82.5/5/102.5/5/102.5/5/10
        Pan diameter/mmΦ80
        Dimensions/mm350×215×340
        Net weight/kg6.8
        power supply110V—220V, 50Hz—60Hz, 5.0V—3.0A, 0.5A
        Power/VA15
        Self-calibration weight value/g100100160200200
        Very good boot warm-up time/min180180180180180
        VS

        YuePing FA1004J Electronic BalanceSpecifications

        LIST VALUE
        Weighing range 0~100g
        Repeatability Error ±0.0002g
        Adjustment Internal calibrated
        Pan Size Φ80mm
        Power 110V—220V、50Hz—60Hz、5.0V—3.0A、0.5A
        Net Weight 6800g
        Dimensions 350*215*340mm
        Actual Graduation d 0.1mg
        Tare Range 0~100g
        Linearity ±0.0005g
        Stabilization time ≤6s
        integration time 2/4/8S adjustable
        Power 15V.A
        Test Weight 100g
        Warm-up time 180min

        YuePing FA1004J Electronic Balance Packing list

        Adapter x1, weight pliers x1, handkerchief x1, instruction manual x1, certificate x1, warranty card x1, weighing plate x1, test weight x1, brush x1, fixing bracket x1, thermometer x1, thermometer clip x1, measurement table x1, glassgraduates with scale x1, liquid components (double hook code, platinum wire, hammer measuring) x1, solid components (net basket) x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Do you have the Electronic Balance involved in GB/T5211.3?
        [A]
        The FA1004J Electronic Balance will do
        YuePing
        YUEPING FA1004J Electronic Balance Weighing range/g: 0~100 Repeatability Error /g: +/- 0.0002
        Service
        Focus on online sales of Lab Testing Instruments