Deguang Electronics C-type Leeb Hardness Tester for measurement of small or thin specimens and surface hardening layers
Deguang Electronics C-type Leeb Hardness Tester probe is suitable for the measurement of small or thin specimens and surface hardening layers. It is an optional impact device for Deguang Electronics Richter Hardness Tester.
DGC-
LANDTEK HM6560 Leeb Hardness Tester Rapid inspection of multiple measurement parts of large workpieces
$ 319.00 -
LANDTEK HM6580 Hardness Gauge error of indication +/- 8HLD Repeatability +/- 6HLD
$ 335.00 -
Leeb Hardness Tester accessories, curved support ring, Deguang Electronics Leeb Hardness Tester accessories
$ 242.00 -
DUBAN DB22-HM450 Leeb Hardness Tester
$ 449.00 -
PRLH320 Leeb Hardness Tester
$ 381.00
Introduction to Type C
Deguang Electronic C-type Leeb Hardness Tester Probe is suitable for measuring small or thin specimens and surface hardened layers. Deguang Electronic Leeb Hardness Tester can be equipped with an impact device.
Probe Measurement Applications
D-type probe : measuring common parts
C-type probe : measure small or thin specimens and surface hardened layers
DC type probe : measure inner surface of inner hole or narrow space
D+15 type probe : measure groove or concave surface
DL type probe : measure slender and narrow groove body
G-type probe : measure large or heavy test pieces and castings and forgings with rough surface
Pictures


DGC Type C Probe (ScleroMeter)Specifications
| LIST | VALUE |
|---|---|
| Impact energy | 3 (Num) |
| Impact device Mass | 3.0g |
| Ball Hardness | 1600HV |
| Ball head diameter | 3mm |
| Ball head material | Tungsen carbide |
| Impact device diameter | 20mm |
| Impact device length | 141mm |
| Impact device Mass | 75g |
| Maximum Specimen Hardness | 1000HV |
| Roughness class standard | N5 (ISO) |
| Maximum Surface Roughness of Specimen | 2.5(UM) |
| Specimen Surface Roughness | 0.4UM |
| Minimum specimen Weight | 1.5kg |
| Requires a stable minimum support Weight | 0.5kg |
| Needs to be coupling time Minimum Film thickness | 0.02kg |
| Minimum test Film thickness | 1mm |
| Minimum depth of hardened layer | 0.2mm |
| Indentation diameter | 0.38mm |
| Indentation depth | 12(un) |
| Indentation diameter | 0.32mm |
| Indentation depth | 8(un) |
| Indentation diameter | 0.30mm |
DGC Type C Probe (ScleroMeter) Packing list
Sclerometer probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Purpose and method of coating hardness testing
- [Film Properties and Measurements] - Determination of film hardness
- Leeb Hardness Tester different hardness system difference
- Coated steel test technology
- How to measure film hardness
- Film Hardness Pencil inspection method
- Optical inspection of ultraviolet curing coatings for PET film - Lv Jianbo
- Film preparation and inspection of Physical and Mechanical Properties - "Determination of film Hardness"
- Classification of Sclerometers [Full]
- Hardness unit conversion table, Brinell Rockwell Vickers hardness conversion formula
- ActiveDL/T 1845-2018
- ActiveGB/T 13313-2008
- ActiveGB/T 17394.1-2014
- ActiveGB/T 17394.4-2014
- ActiveGB/T 17394.3-2022
- ActiveGB/T 17394.2-2022
- AbolishGB/T 17394-1998
- AbolishGB/T 17394.3-2012
- AbolishGB/T 17394.2-2012
- ActiveJB/T 9378-2001






