Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Gas detector> HuiRuiPu> HuiRuiPu GT-H10-H2 Fixed gas alarm

      HUIRUIPU GT-H10-H2 Hydrogen Fixed Gas Alarm 1000PPM

      Detection gas H2 hydrogen, range 0-1000PPM, resolution 1PPM, low alarm point: 50PPM; high: 150PPM.

      Brand
      SKU: NB048340
      China HuiRuiPu
      VS
      Genuinegoods
      • HuiRuiPu GT-H10-H2 Fixed gas alarmOverview

      • Specifications
      • Comments
      • FAQs
      GT-H10-H2
      Fixed gas alarm
      • HUIRUIPU GT-H10-H2 Hydrogen Fixed Gas Alarm 1000PPM
      • HUIRUIPU GT-H10-H2 Hydrogen Fixed Gas Alarm 1000PPM Figure 1
      • HUIRUIPU GT-H10-H2 Hydrogen Fixed Gas Alarm 1000PPM Figure 2
      Detection gas H2 hydrogen, range 0-1000PPM, resolution 1PPM, low alarm point: 50PPM; high: 150PPM.

      GT-H10 fixed gas alarm is used to detect the concentration of flammable gas or other toxic and harmful gases in the air, when the concentration reaches or exceeds the preset alarm value, the controller will send out an audible and visual alarm, timely remind to take safety measures, prevent explosion and poisoning accidents, so as to protect life and property safety.

      This product adopts industrial-grade sensor, the instrument shell adopts a die-cast aluminum shell designed with explosion-proof and explosion-proof structure, and the groove design of the upper cover can lock the shell and the front of the sensorIt is designed as a downward structure to ensure that the sensor is in good contact with the gas, and the inlet adopts explosion-proof and waterproof joints. It can be widely used in metallurgy, petroleum, chemical industry, municipal and other industries

      peculiarity

      • Dustproof, explosion-proof, anti-static, anti-reverse connection, anti-interference, surge protection function;

      • Detection accuracy and range are adjustable;

      • Long life, high sensitivity, low drift, stable and reliable work;

      • Sensor fault self-check, two-level concentration alarm, with relay output function;

      • LCD display/digital display, working status indication;

      • Zero point automatic tracking, automatic temperature compensation, concentration over-range protection, multi-point calibration function;

      • At the same time, it supports two-wire (PowerBus), three-wire (4~20mA), four-wire (RS485) signal output and Lora/4G Internet of Things signal transmission

      • out, PLC, DCS and cloud platform can be uploaded;

      • Infrared remote control mode, the Detector can be adjusted without opening the cover, which is safe and convenient;

      • Pluggable module sensor design, convenient for later maintenance;

      • Flameproof design is suitable for hazardous conditions 1 and 2;

      Serial models

      The gas to be measuredMeasuring rangeresolutionAlarm point
      EX is combustible and combustible0-100%LEL1%LEL/1%VOL Low: 20; High: 50
      O2 oxygen0-30%VOL 0.1%VOL Low: 19.5% VOL; High: 23.5% VOL
      H2S hydrogen sulfide0-100PPM 0.1PPMLow: 10PPM; HEIGHT: 20PPM 
      CO carbon monoxide0-1000PPM 1PPMLow: 50PPM; HEIGHT: 150PPM
      NO2 nitrogen dioxide0-20PPM 0.1PPM Low: 5PPM; HEIGHT: 10PPM 
      CO2, carbon dioxide0-5000PPM/0-5%VOL1PPM/0.1%VOLLow: 2000; High: 4000 
      NO nitric oxide0-250PPM 1PPMLow: 50PPM; HEIGHT: 150PPM 
      SO2 sulfur dioxide0-20PPM 0.1/1PPM Low: 5PPM; HEIGHT: 10PPM
      CL2 chlorine0-20PPM 0.1PPMLow: 5PPM; HEIGHT: 10PPM 
      NH3 ammonia0-100PPM0.1/1PPMLow: 20PPM; HIGH: 50PPM
      H2 hydrogen0-1000PPM 1PPMLow: 50PPM; HEIGHT: 150PPM
      PH3 phosphine0-20PPM0.1PPM Low: 5PPM; HEIGHT: 10PPM 
      HCL hydrogen chloride0-20PPM 0.1PPM Low: 5PPM; HEIGHT: 10PPM 
      CLO2 chlorine dioxide0-50PPM0.1PPM Low: 5PPM; HEIGHT: 10PPM


      VS

      HuiRuiPu GT-H10-H2 Fixed gas alarmSpecifications

      LIST VALUE
      Detect gas H2 hydrogen
      Range 0-1000PPM
      resolution 1PPM
      alarm point Low: 50PPM; High: 150PPM

      HuiRuiPu GT-H10-H2 Fixed gas alarm Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +HuiRuiPu GT-H10-H2 Fixed gas alarm Big data
        +HuiRuiPu GT-H10-H2 Fixed gas alarmSimilar products
        +Navigation
        HuiRuiPu
        HUIRUIPU GT-H10-H2 Hydrogen Fixed Gas Alarm 1000PPM
        Service
        Focus on online sales of Lab Testing Instruments