JINHE JY-PHb contact angle tester, automatic test, static drop method, increasing or decreasing drop method, inclined plate method
Static drop method, droplet method, inclined plate method can be measured, with High Accuracy Optical inspection swirl/spin table, drive the stage concentric swirl/spin, to achieve the turning method to test the forward angle and the backward angle, for the measurement of solid, liquid and gas contact angle between the three phases.
JinHe-
FANGRUI JCY-3 Contact Angle Analyzer, no inclined platform can measure surface tension
$ 3431.00 -
CHINA JY-82A automatic video contact angle Tester
$ 5676.00 -
FANGRUI JCY-2 Contact Angle Analyzer image analysis method surface tension Measurement Instrument
$ 3245.00 -
JINHE JY-PHb contact angle Tester, automatic test, static drop method, increasing or decreasing drop method, inclined plate method
$ 3545.00 -
JINHE JY-PHc contact angle Tester Automatic analysis of contact angle/surface tension, automatic sample injection
$ 4176.00
The JY-PHb contact angle meter is used to measure the contact angle between the three phases of solid, liquid and gas. By measuring the contact angle, the adhesion of the liquid to the solid, the surface energy of the solid and other surface physical and chemical properties are calculated and measured. The instrument is widely used in the fields of petroleum, chemical, papermaking, dyes and various new materials research and manufacturing. Computer technology is used to transfer the ingested images into the computer for storage, analysis and printing. Fast speed, accurate data, and easy operation. The equipment has automatic contact angle analysis function, high degree of automation, high measurement accuracy.
Key features:
Automated contact angle analysis
Using machine vision technology, the baseline and droplet contours are automatically identified, and the quadratic curve fitting calculation is carried out based on the Laplace equation to obtain the contact angle value. The effect of gravity on the shape of the droplet is reduced, and the human test error is eliminated. Fully automatic testing can be achieved for images with obvious baseline features, and the baseline position needs to be manually specified for images with obvious baseline features.
Test methodology
1. Static drip method
Drop a drop of liquid on the solid surface, take a picture of the equilibrium system after the solid-liquid-gas three-phase interface is balanced, and measure the contact angle through the contact angle measurement method provided by the software. The balancing process can also be photographed or videotaped regularly during the test, and then the system change process can be analyzed.
2. Increase and decrease droplet method
Due to the existence of inhomogeneity on the solid surface, it is sometimes necessary to measure the dynamic contact angle to analyze the hysteresis phenomenon of the contact angle, and this instrument can measure the forward angle by continuously increasing the droplet volume or continuously decreasing the droplet volume to measure the backward angle.
3. Tilting plate method(JY_PHb type)
The JH_PBb has a function, its stage can be electrically rotated to form an inclination angle, and the droplet is tilted to one side under the action of gravity until it rolls, which can determine the forward and retreat angles of the droplet.
Contact angle analysis method
Automated analysis method:
For most pictures, one-click result analysis can be realized, using computer vision analysis technology, quadratic curve fitting method, automatic measurement and calculation of results. For a small number of images with inconspicuous baseline characteristics, the baseline method is manually specified and automatically measured. The display accuracy is 0.1°. This method basically overcomes the influence of gravity on the shape of droplets, improves the test accuracy, and eliminates human error.
The tangent method measurement method is measured by manually drawing the baseline and arc tangents, which is suitable for images with severe asymmetry, and is analyzed manually, with a display accuracy of 0.1°.
The measurement method of the height method is to calculate the contact angle value by drawing the external rectangle of the droplet, and the contact angle value is displayed with an accuracy of 0.1°.
The angle measurement method realizes the measurement of the contact angle by drawing the protractor. The contact angle value shows an accuracy of 0.1°.
The chord height method is measured, and the contact angle value is displayed with an accuracy of 0.1°.
The elliptic fitting method is measured, and the contact angle value shows an accuracy of 0.1°.
The contact angle measurement range of all methods is 0~180°
Video processing methods
Small window preview, large window photo and analysis. The main interface of the software has a video display window, which is used to display the video captured by the camera or the video file played. Click on the thumbnail after taking the photo to enter the contact angle analysis interface, which is easy to operate.
Video recording and image capture functions. The test process can be recorded in real time, and the software can capture photos frame by frame after recording the video, which is convenient for capturing rapid dynamic changes.
Single photo function. The current frame displayed in the video is captured and saved, and displayed as a thumbnail in the main window.
Continuous timing camera function, the timing time can be adjusted arbitrarily. The interval between photos can be set, and the photo will be taken automatically after the interval time is reached, which is convenient for analyzing the dynamic change process of contact angle.
Document and image management
You can save a single image and select the analysis tool that appears on the image.
All test data and pictures can be saved as a whole.
The test results are displayed as a list and can be exported to an Excel file.
The brightness, contrast, chromaticity and other information of the camera image and the brightness of the backlight are adjusted by the software settings.
You can set the save path for videos and photos.
Photo results image zoom and crop functions.
Surface energy calculation
The surface energy calculation function provides the Fowkes equation, Owens equation, and YGGF equation calculation methods.
operating environment
Uses 64-bit Windows operating system.
It is recommended that the memory is more than 4G, and the hard disk space is not less than 10G.
JinHe JY-PHb Contact angle testerSpecifications
| LIST | VALUE |
|---|---|
| video capture | Adopt domestic (CN) high-end industrial camera |
| Maximum image resolution | 2048 * 1536 pixels |
| video output | USB2.0 output, computer control gain, luminance, exposure time. USB power supply, no separate power supply. |
| signal-to-noise ratio | >52dB |
| exposure time | 17uS~2.3S |
| Lens characteristics | Domestic (CN) High-end Zoom Microscope Head |
| zoom ratio | 0.7~4.5X |
| magnification | 30~ 130 times |
| Best shooting distance | 95mm |
| tube length | 165mm |
| Lens Adjustment Stand Features | Adopt F-type special lens holder, adjustment range: 60mm |
| Stage mobile | Manual, smooth Optical inspection parts X direction (horizontal): 80mm, accuracy 0.1mm; Y direction (vertical): 30mm, accuracy 0.1mm; Z direction (up and down): 50mm |
| Swirl/spinning table characteristics | Domestic (CN) High Accuracy Optical inspection swirl/spin table, drive the stage concentric swirl/spin to realize the turning method to test the forward and backward angles |
| Swirling/spinning | Computer control, high-subdivision stepper motor drive, and manual adjustment |
| Rotation angle | ≥90° |
| Swirl/spin speed | Computer software adjustment |
| Angular scale resolution | 1° |
| Illuminant | Monochrome Semiconductor Illuminant, continuous adjustable luminance |
| maximum frame rate | 25 frames per second |
| dimensions | 600*310*450mm |
JinHe JY-PHb Contact angle tester Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


JY-PHb