Huicheng DTA-1250 Differential Thermal Analyzer Differential Thermal Analysis Linear dispersion 1250 ℃
New fully enclosed Ceramics furnace body design structure, more high temperature resistance
HuiCheng-
LANDTEK FM-100V10 Portable Flow velocity measuring instrument, Open channel Flow velocity Flow rate measurement
$ 677.00 -
AMITTARI WA-160A Water Activity Meter
$ 660.00 -
China NBC-9012 Battery Thermal Shock Test Chamber, Battery Thermal Shock test, capacity 64L
$ 2059.00 -
YUZHOU PG-1A metallographic sample polishing machine, the diameter of the throwing plate is 230mm
$ 319.00 -
CHINA NBC-YX-2010 Manual two-dimensional image Measurement Instrument 200 × 100mm
$ 2640.00
Differential thermal analysis is a technique that measures the temperature difference between a substance and a reference at a programmed temperature. The differential thermal analysis curve describes the temperature (△T) between the sample and the reference material as a function of temperature or time. In DTA tests, changes in sample temperature are due to phase transitions or endothermic or exothermic effects of the reaction. Such as: phase transformation, melting, transformation of crystalline structure, boiling, sublimation, evaporation, dehydrogenation, fracture or decomposition reaction, oxidation or reduction reaction, destruction of crystal lattice structure and other chemical reactions.
Instrument Usage
Phase transitions, melting, transformation of crystalline structures, boiling, sublimation, evaporation, dehydrogenation, fracture or decomposition reactions, oxidation or reduction reactions, destruction of lattice structure and other chemical reactions.
Features
The new fully enclosed ceramic holding furnace design structure greatly improves the sensitivity and resolution, as well as better baseline stability.
Imported alloy sensor is adopted, which is more corrosion-resistant, anti-oxidation, and has high sensor sensitivity.
The Cortex-M3 core ARM controller is used for faster computing and processing speed, and more accurate temperature control.
USB two-way communication is used to fully realize intelligent operation.
It adopts a 7-inch 24-bit color full-color LCD touch screen to display the status and data of the instrument in real time.
Intelligent software design, automatic drawing of the instrument throughout the process, and the software can realize various data processing, such as the calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc.
HuiCheng DTA-1250 Differential Thermal AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| temperature range | Room temperature~ 1250 ℃ |
| Range | 0~±2000μV |
| DTA Accuracy | ±0.01μV |
| Heating rate | 0.1~80℃/min |
| Temperature Resolution | 0.01℃ |
| Temperature Accuracy | ±0.1℃ |
| Temperature, repeability | ±0.1℃ |
| temperature control | Heating up: program control, parameter adjustment can be carried out according to needs Cooling: air cooling, program control thermostatic: program control thermostatic time can be set arbitrarily |
| Furnace structure | The furnace body adopts the upper open-lid structure, replacing the traditional lifting furnace body, with high Accuracy and easy operation |
| atmosphere control | Internal program automatic switching |
| Data Interface | Standard USB interface, supporting data cable and operating software |
| display mode | 24Bit color 7-inch LCD touch screen display |
| parameter standard | Equipped with standard, with a key to calibrate function, users can correct the temperature by themselves |
| Baseline adjustment | Users can adjust the Baseline by its slope and intercept |
| Power Supply | AC 220V 50Hz |
HuiCheng DTA-1250 Differential Thermal Analyzer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


DTA-1250