CHINA brand RBX-006 Microcomputer-controlled thermal deformation Vicat temperature Tester
Equipped with high-precision displacement Sensors and an automated heating system, the Windows 7 graphical Operating interface makes it easier for users to operate, and the specimen rack can test three samples at a time.
Factory-
Huicheng DSC-600C/-20~600 Differential Scanning Calorimeter -20 ℃~ 600 ℃
$ 6133.00 -
SuJie ZJ-1200 Mobile Air Self-purifier 820 * 610 * 120mm
$ 1563.00 -
DUBAN DB25-204M Muscle Strength Tester Measurement range +/- 490N
$ 382.00 -
YOUKE YK3057 Leakage marking Tester, leakage resistance marking test
$ 1485.00 -
DZ-DSC300A Differential Scanning Calorimeter 0 ℃~ 600 ℃
Login
Features and uses
The Vicat softening point temperature Tester is suitable for testing the Vicat softening point temperature and heat deflection temperature of polymer materials, as an indicator to control the quality and identify the thermal properties of new varieties. THE DEFORMATION IS MEASURED BY A HIGH-PRECISION DISPLACEMENT SENSOR, THE SOFTWARE AUTOMATICALLY SETS THE HEATING RATE, AND THE WINDOWS 7 OPERATING SYSTEM PLATFORM USES THE SOFTWARE DEDICATED TO MEASURING THE HEAT DEFLECTION TEMPERATURE AND VICAT SOFTENING POINT TEMPERATURE WITH GRAPHIC VISUALIZATION, SO THAT THE OPERATION IS MORE FLEXIBLE AND THE MEASUREMENT IS MORE ACCURATE. The specimen holder is automatically raised and lowered, and 3 specimens can be tested at a time. Novel design, beautiful appearance and high reliability. This testing machine meets the requirements of GB/T 1633 "Test Method for Softening Point (Vika) of Thermoplastics", GB/T 1634 "Test Method for Thermal Deformation Temperature of Plastic Bending Load" and ISO75 and ISO306.
structure
The testing machine is mainly composed of a frame, an oil tank, an electric heating pipe, a cooling pipe, a specimen support, a lifting mechanism, etc. The oil tank is used to store the heating medium methyl silicone oil, and the specimen holder is used to place the specimen. The entire test operation is controlled by computer. The operation is convenient, safe and reliable. The structure of the specimen holder is shown in the figure

Factory RBX-006 Microcomputer-controlled thermal deformation Vicat temperature TesterSpecifications
| LIST | VALUE |
|---|---|
| Temperature control range | RT+~350℃ |
| Heating rate | (12±1)℃/6min[(120±10)℃/h] (5±0.5)℃/6min[(50±5)℃/h] |
| Maximum temperature error | ±0.5℃ |
| Measurement range | 0~10mm |
| Deformation measurement error | 0.001mm |
| number of sample racks | Six. |
| Heating medium | Methyl silicone oil |
| Heating power | 4kW |
| Cooling mode | Natural chill down above 150 ° C, water-cooled or natural chill down below 150 ° C |
| Power Supply | AC220V±10% 20A 50Hz |
| exterior size | 720*700*1380mm |
| Weight | 180kg |
| Load bar and head Weight | 88g |
| Print function | Printing Temperature - Linear dispersion and related test parameters |
Factory RBX-006 Microcomputer-controlled thermal deformation Vicat temperature Tester Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


RBX-006