CHINA LS197 three-angle Glossmeter 20 °/60 °/85 ° multi-angle measurement
Measurement, 20 °/60 °/85 ° Multi-angle Measurement mode, large range design, up to 2000GU, in line with the national first-class working machine standard, D65 Light source, ready to test, support PC software, generate test reports.
Factory-
QILI SMN268 full smart Glossmeter
$ 817.00 -
IWAVE WG60 Glossmeter 60 ° inks paints, wood, marble, granite, ceramics, plastics, paper, etc
$ 270.00 -
Paint Glossmeter JFL-BZ60MP (metal coatings dual-use smart) JFL
$ 338.00 -
Intelligent Glossmeter JFL-BZ60 (smart) JFL coating, printing and other gloss Measurement Instrument
$ 296.00 -
3NH HG60 single angle Glossmeter 60 degree single angle Glossiness detection instrument
Login
Introduction
LS197 is a multi-angle design gloss meter, the body is made of ivory engineering plastic shell, the appearance is simple and elegant. It has three measurement angles of 20°, 60° and 85°, and the gloss of different angles can be measured at the same time. With a measuring range of up to 2000 GU, it can measure high-gloss and even specular reflective materials. The operation is simple, put and measure, no need to wait. The instrument supports normal mode and QC mode, in QC mode, it can automatically determine whether the gloss of the material is qualified or not, and improve the detection efficiency. The instrument is widely used in the surface gloss test of coatings, paints, inks, plastics, ceramic tiles, paper, ceramics, stones, metals and other materials.
Features
The unique design of 20°, 60° and 85° three-angle testing is adopted, and the gloss at different angles can be measured at the same time, which truly makes the measurement easier.
With a measuring range of up to 2000GU, it can measure high-gloss and even specular reflective materials to meet the different measurement needs of customers.
Single-angle/dual-angle/multi-angle measurement is freely collocated, and the angle is optional.
With the D65 light source, the receiver spectral response curve conforms to the spectral visual function V(λ), which ensures more accurate measurement of colored objects.
Using imported chips and sensors, with 50-point linear fitting algorithm, the repeatability can reach ±0.2GU and the resolution can reach 0.1GU.
The accuracy in the full range meets the national first-class working machine standard, which can ensure that it can pass the test of the National Institute of Metrology.
After the instrument is turned on, there is no need to press the button to operate, and it can be put on and measured.
In addition to normal mode, the instrument also supports QC mode. In this mode, the user can customize the upper and lower limits for qualified judgment, which is suitable for batch inspection.
The instrument supports online measurement, and the computer can intelligently count the data and generate a measurement report, making the measurement more professional.
The body is made of ivory engineering plastic shell, the design is user-friendly, and the streamlined body brings a comfortable grip, making long-term measurements effortless.















Factory LS197 GlossmeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement angle | 20°/60°/85° |
| Measurement range | 20°:0~2000GU、60°:0~1000GU、85°:0~160GU |
| Measuring Area | 20°:9mm*9mm、60°:9mm*15mm、85°:5mm*38mm |
| Minimum size of test object | 57mm*10mm |
| Body material | Engineering Plastics |
| Graduation | 0.1GU |
| Repeatability | 0~100GU: +/- 0.2GU/100~2000GU: +/- 0.2% reading |
| reproducibility | 0~100GU: +/- 0.5GU/100~2000GU: +/- 0.5% reading |
| Zero Error | 0.1GU |
| error of indication | 0~100GU: +/- 1.5GU/100~2000GU: +/- 1.5% reading |
| Power Supply | Rechargeable lithium battery |
| system language | Simplified Chinese, English |
| Charging port | USB(Type-C) |
| Interface | USB |
| Operating temperature | 10~45 ℃, 0~85% RH (no condensation) |
| Storage temperature | -10~60℃ |
| Storage Humidity | 0~85% RH (no condensation) |
Factory LS197 Glossmeter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Glossmeter in inks printing detection
- Application of Glossmeter in PE film detection
- Application of Glossmeter in gloss detection of gold-plated surface
- Application of Glossmeter in Spinning & weaving gloss detection
- Printing Encasement gloss detection solution
- Application of Glossmeter in paper surface gloss detection
- Glossmeter FAQ and its solution
- How to apply Glossmeter to leather sofa gloss detection?
- Furniture panel gloss detection application scheme
- How to detect mobile phone film gloss?
- IncomingGB/T 9754-2025
- ActiveGB/T 23454-2025
- ActiveASTM D523-2008
- ActiveISO 2813-2014
- ActiveASTM D523-2018
- ActiveGB/T 7706-2008
- ActiveGB/T 8807-1988
- DIN 67530-1982
- ActiveASTM D2457-2021
- ActiveGB/T 13891-2008
- ActiveGB/T 9754-2007
- ActiveISO 2813-2014
- AbolishGB/T 9754-1988


LS197