Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Gas detector> GUOYUGR> GUOYUGR GY/VGD-200-C2H6S-G(0-10ppm) Methyl sulfide Detector

      GUOYUGRA GY/VGD-200-C2H6S-G (0-10ppm) methyl sulfide Detector

      Conventional, leak detection, optional PID, supports a variety of signal output (4-20mA, RS485 and wireless transmission), adapts to industrial systems such as PLC and DCS, and supports remote cloud platform monitoring and alarm functions.

      Brand
      SKU: NB048742
      China GUOYUGR
      Stock
      Loading…
      Price
      $ 879.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • GUOYUGR GY/VGD-200-C2H6S-G(0-10ppm) Methyl sulfide DetectorOverview

        • Specifications
        • Comments
        • FAQs
        GY/VGD-200-C2H6S-G(0-10ppm)
        Methyl sulfide Detector
        • GUOYUGRA GY/VGD-200-C2H6S-G (0-10ppm) methyl sulfide Detector
        • GUOYUGRA GY/VGD-200-C2H6S-G (0-10ppm) methyl sulfide Detector Figure 1
        • GUOYUGRA GY/VGD-200-C2H6S-G (0-10ppm) methyl sulfide Detector Figure 2
        Conventional, leak detection, optional PID, supports a variety of signal output (4-20mA, RS485 and wireless transmission), adapts to industrial systems such as PLC and DCS, and supports remote cloud platform monitoring and alarm functions.

        Introduction

        The gas concentration Detector is a low-power modular design with MCU chip, intelligent sensor detection technology, integral flameproof (d) structure, and fixed installation method. The standard configuration is LCD tft high-definition liquid crystal display, three-wire 4~20mA analog, RS485 digital and switching signal output, providing customized products according to user needs, and also supporting output signal fine-tuning and other functions, which is convenient for system networking and maintenance.

        Enforce the standard

        • GB/T3836.1-2021 "Explosive atmospheres Part I: General requirements"

        • GB/T3836.31-2021 "Explosive atmospheres Part 31: Equipment protected by anti-dust ignition enclosure "t"

        • GB3836.15-2000 "Electrical Equipment for Explosive Gas Atmospheres Part 15: Electrical Installation in Hazardous Locations (Except Coal Mines)"

        • GB12476.1-2013 "Electrical Equipment for Combustible Dust Environments Part 1: General Requirements" GB12358-2006 "General Technical Requirements for Workplace Ambient Gas Detection and Alarm Instruments"

        • GBZ2.1-2007 "Occupational Exposure Limits for Hazardous Factors in the Workplace"

        • GB4208-2008

        Features

        • The use of customizable range intelligent sensors ensures the advantages of high sensitivity, high precision, stable linearity, and fast response of the Detector.

        • The MCU chip is used, which highlights the low power consumption, safe and reliable performance, accurate data conversion, and stable signal output of the Detector. 4-20mA, RS485, switching and other signal outputs, easy to access PLC, DCS, DDC and other industrial control systems, can also be linked to fans, solenoid valves and other control equipment through switching units;

        • Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.;

        • Dot matrix high-definition LCDTFT LCD screen, Chinese and English operation interface can be switched by itself;

        • The Detector can be operated by remote control without opening the cover, such as alarm value, zero adjustment, calibration, reset, modification of address code and other function menus;

        • Local integrated sound and light alarm indication can realize remote mobile phone, computer, monitoring room, third-party platform and other alarm prompts through alarm control host or wireless signal, and can also be infrared remote control one-key silencing;

        • Aluminum alloy cast explosion-proof shell, strong and durable;

        • It has passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications.

        • Explosion-proof certificate level: Ex db IIC T6 Gb;

        • Explosion-proof certificate number: SYEx23.04100.

        Product Dimension Drawing

        Guoyu Technology GY/VGD-200-C2H6S-G(0-10ppm) Methyl Sulfide Detector Details Figure 1

        Product installation recommendations

        Guoyu Technology GY/VGD-200-C2H6S-G(0-10ppm) Methyl Sulfide Detector Details Figure 2

        Gas types and capacities are available

        GY/VGD-200 host other measurable toxic gas list
        The name of the gasmolecular formulaMeasuring range (ppm)The name of the gasmolecular formulaMeasuring range (ppm)
        carbon monoxideCO0-200/1000/2000SilanesS IH40-20/50
        oxygenO20-25%/30%/100%hydrogen peroxideH2O20-50/100/2000
        hydrogen sulfideH2S0-50/100/200/500phosgeneCOCL20-1
        hydrogenH20-1000/2000/40000chlorine dioxideCLO236545
        sulfur dioxideSO20-20/100/200/2000FluorineF20-1
        nitrogen dioxideNO20-20/100/2000TetrahydrothiopheneC4H4S0-50 mg/m3
        nitric oxideNO0-20/100/2000Hydrogen selenideSEH20-5
        chlorineCL20-20/200hydrogen fluorideHF0-10
        hydrogen chlorideHCL0-20/50/200Methyl mercaptanCH3SH0-10
        flammabilityEX0-1/5/100/2000carbon dioxideCO20-2000/5000/10000
        formaldehydeCH2O0-10/50/100ethyleneC2H40-10/20/100/2000
        ethylene oxideC2H4O0-10/50/100/500Hydrogen bromideHBR0-20/200
        hydrazineN2H40-1BromineBR20-20/200
        ammoniaNH30-50/100/1000Hydrogen arsenicASH30-1
        flammabilityEX0-20/30/100ozoneO30-1/5/10/50/100/200
        Sulfur hexafluorideSF60-1000 ,2000EthylboraneB2H60-1
        freonCFC/R5070-1000/2000RefrigerantRX0-2000/5000
        freonR12/R220-1000/2000freonR113/R1140-1000/2000
        freonR125/R2900-1000/2000freonR134a/R404a0-1000/2000


        VS

        GUOYUGR GY/VGD-200-C2H6S-G(0-10ppm) Methyl sulfide DetectorSpecifications

        LIST VALUE
        detection medium C2H6S
        receiving device User computer, control alarm, PLC, DCS, DDC, etc
        Operating Mode diffusion
        Detection principle Catalytic combustion
        detection range 0-10Pm (optional 50ppm, 100ppm, 1000ppm, 5000ppm)
        resolution 0.01
        detection error ≤ +/- 3% F. S (≤ 3% in full scale)
        repeatability ≤±2%
        Linearity ≤±2%
        Response time ≤30S
        Operating Voltage DC24V( 12V ~30V)
        Operating temperature -20 ℃~ 50 ℃ (Special requirements: (-40 ℃~ + 70 ℃)
        Operating humidity 10-95% RH (non-condensing)
        Sensors Life 2 to 3 years (depending on the environment used)
        Explosion-proof form Probe Transmitters and Sensors are flameproof.
        Connecting cable ① 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters (with a Detector), the single Wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth. ② Wireless transmission: can be built-in LORA, Zigbeg module, short-range wireless transmission; can be external GPRS/4G module, remote data transmission to cloud platform, can view history on computer and mobile phone, no distance limit (optional)
        Alarm mode On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, etc
        Alarm settings Standard configuration Two-level alarm; Alarm mode can be set: conventional high and low alarm, interval control alarm
        Dimension 182*201*92( L*W*H)
        electrical interface Default M20X1.5 internal thread, optional 3/4NPT, 1/2NPT
        Measurement Certificate Optional, user pays
        Optional Accessories 220V to 24V power adapter. Computer monitoring accessories: free host computer software, USB to RS485 conversion cable, RS485 to network port converter
        Output signal 1 ① 4-20mA signal: standard 12-bit Accuracy 4-20mA output chip, transmission distance 1Km; ② RS485 signal: using standard MODBUS RTU protocol, transmission distance 1Km
        Output signal 2 ③ Voltage signal: 0.4-2 V, 0-5V, 0-10V output, optional (Voltage output and current output choose one); ④ Switching signal: standard 1 group of passive touchpoint relays, Capacity 220VAC 3A/24VDC 3A; ⑤ GPRS, 4G, WI FI, LORA, ZigBee and other wireless signals

        GUOYUGR GY/VGD-200-C2H6S-G(0-10ppm) Methyl sulfide Detector Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.