      CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection

      Built-in Vacuum Pump, particle size six channels, built-in printer, AC/DC dual-use, touch screen, detection range covering 100 to 1 million, can directly determine the cleanliness level.

      Brand
      SKU: NB049091
      China Factory
      Model
      Stock
      Loading…
      Price
      $ 817.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Factory CA-680 Dust Particle CounterOverview

        • Specifications
        • Comments
        • FAQs
        CA-680
        Dust Particle Counter
        • CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection
        • CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection Figure 1
        • CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection Figure 2
        Built-in Vacuum Pump, particle size six channels, built-in printer, AC/DC dual-use, touch screen, detection range covering 100 to 1 million, can directly determine the cleanliness level.

        Introduction

           The CA-680 laser dust particle counter (hereinafter referred to as the instrument) is used to measure the particle size distribution and number of dust particles per unit volume in a clean environment, and can directly detect and determine the clean environment with a cleanliness level of A or B area. With excellent functions and characteristics, the instrument provides 0.3, 0.5, 1.0, 3.0, 5.0, 10μm six channels with specific particle size and 2.83L/min (1ft3/min) flow rate. Provide you with a complete solution. The instrument adopts semiconductor laser light source, large-size touch LCD screen display, its small size, light weight, high detection accuracy, simple and clear function operation, microcomputer control, can directly print sampling and testing results, and the test clean environment is very convenient.

        Operating Principle

        This instrument adopts the principle of light scattering, through the detection laser of the laser optical sensor for perception, the light scattering intensity is proportional to the luminous flux of its particle size, when the suspended particles in the air pass through the photosensitive area, the scattered scattered light is accepted by the photosensitive element and generates a pulse signal, and the diameter and number of the collected particles are obtained after photoelectric conversion, amplification and processing, so as to detect the size and number of dust particles.

        Scope of application

        The instrument is widely used in the electronics industry, pharmaceutical industry, semiconductor industry, optics, precision machining fields, food manufacturing, cosmetics manufacturing, medicine and health, biological products, hospitals, environmental protection, laboratories, aerospace and other industries production enterprises and scientific research departments, as well as epidemic prevention stations, disease control centers, blood centers, quality supervision institutes and other institutions.

         Features

        •   Touchscreen control makes operation easier and data results more intuitive

        •    The sampling volume is directly 2.83L/min

        •   Six-channel particle size sampling 0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm

        •    UCL calculation (at 95% confidence) for direct display of particle concentration

        •   According to the classification and regulations of the purification level, the purification level is automatically determined, which is convenient to use.

        •    AC/DC configuration is optional

        •    Long-life laser light source, stable performance

        •    Built-in high-speed thermal printer

        •   The printing method is optional, automatic instant printing, and manual selection of printing function

        •    AC and DC dual-purpose, built-in rechargeable lithium battery, environmentally friendly and durable, can support continuous sampling for more than 6 hours

        According to the standard

        National standard: GB/T6167-2007 Dust particle counter performance test method

        Cleanliness level judgment standard: ISO14644 FS209E, new GMP (dynamic/static) calibration specification: JJF-1190-2008


        VS

        Factory CA-680 Dust Particle CounterSpecifications

        LIST VALUE
        Light source Semiconductor Laser Light source (lifetime greater than 30,000 hours)
        Sampling flow rate Built-in vacuum pump, 2.83L sampling
        particle size channel Six channels, 0.3, 0.5, 1.0, 3.0, 5.0, 10 (μm)
        Particle size distribution error 0.5um 5um ≤±30%
        An indication of particle concentration error 0.5um ≤±30%
        detection range 100 to 1 million
        UCL Report In line with Chinese GMP standards
        sampling period 1S - 9999999s self-set
        Sampling Delay 1S - 9999999s self-set
        Sampling points 2 - 50 points can be set arbitrarily
        Sampling times 2-50 times, any setting
        Sampling area According to requirements, any combination of letters and numbers or individually set
        Sampling unit Piece, Piece/m ³, Piece/FT3 and other three unit options
        self-purification time ≤10min
        Operating Environment Temperature 10 ℃ - 35 ℃ Relative Humidity ≤ 75% atmospheric pressure 86kPa - 106kPa
        Sampling conditions Sampling gas shall not contain acid, alkali, high temperature and other corrosion gases
        data printing Built-in high-speed thermal printer
        Display mode 5-Inch color touch screen
        Battery Capacity Built-in 4000mAh
        average power consumption 7.5W
        Dimension 220*230*130(W*L*H)mm
        Weight 2.8KG

        Factory CA-680 Dust Particle Counter Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +Factory CA-680 Dust Particle Counter Big data
          +Navigation
          Factory
          CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection
          Service
          Focus on online sales of Lab Testing Instruments