CA-680 Dust Particle Counter Particle size distribution and number, cleanliness detection
Built-in Vacuum Pump, particle size six channels, built-in printer, AC/DC dual-use, touch screen, detection range covering 100 to 1 million, can directly determine the cleanliness level.
Factory-
GUOYUGRA GY/VGD-200-NO-G (0-20ppm) nitric oxide Detector
$ 270.00 -
HUIRUIPU HRP-T1000-H2S Hydrogen sulfide Gas Detector (No Lights, LCD Model)
$ 165.00 -
BOSEAN BH-90-O3 Portable Gas Alarm 0~20ppm
$ 226.00 -
GUOYUGRA GY/VGD-200-R404a-G high-precision refrigerant, refrigerant Detector 0-1000ppm
$ 1190.00 -
Empaer AATL-SO2 (sound and light alarm) Pathfinder series fixed sulfur dioxide Detector
$ 633.00
Introduction
The CA-680 laser dust particle counter (hereinafter referred to as the instrument) is used to measure the particle size distribution and number of dust particles per unit volume in a clean environment, and can directly detect and determine the clean environment with a cleanliness level of A or B area. With excellent functions and characteristics, the instrument provides 0.3, 0.5, 1.0, 3.0, 5.0, 10μm six channels with specific particle size and 2.83L/min (1ft3/min) flow rate. Provide you with a complete solution. The instrument adopts semiconductor laser light source, large-size touch LCD screen display, its small size, light weight, high detection accuracy, simple and clear function operation, microcomputer control, can directly print sampling and testing results, and the test clean environment is very convenient.
Operating Principle
This instrument adopts the principle of light scattering, through the detection laser of the laser optical sensor for perception, the light scattering intensity is proportional to the luminous flux of its particle size, when the suspended particles in the air pass through the photosensitive area, the scattered scattered light is accepted by the photosensitive element and generates a pulse signal, and the diameter and number of the collected particles are obtained after photoelectric conversion, amplification and processing, so as to detect the size and number of dust particles.
Scope of application
The instrument is widely used in the electronics industry, pharmaceutical industry, semiconductor industry, optics, precision machining fields, food manufacturing, cosmetics manufacturing, medicine and health, biological products, hospitals, environmental protection, laboratories, aerospace and other industries production enterprises and scientific research departments, as well as epidemic prevention stations, disease control centers, blood centers, quality supervision institutes and other institutions.
Features
Touchscreen control makes operation easier and data results more intuitive
The sampling volume is directly 2.83L/min
Six-channel particle size sampling 0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm
UCL calculation (at 95% confidence) for direct display of particle concentration
According to the classification and regulations of the purification level, the purification level is automatically determined, which is convenient to use.
AC/DC configuration is optional
Long-life laser light source, stable performance
Built-in high-speed thermal printer
The printing method is optional, automatic instant printing, and manual selection of printing function
AC and DC dual-purpose, built-in rechargeable lithium battery, environmentally friendly and durable, can support continuous sampling for more than 6 hours
According to the standard
National standard: GB/T6167-2007 Dust particle counter performance test method
Cleanliness level judgment standard: ISO14644 FS209E, new GMP (dynamic/static) calibration specification: JJF-1190-2008
Factory CA-680 Dust Particle CounterSpecifications
| LIST | VALUE |
|---|---|
| Light source | Semiconductor Laser Light source (lifetime greater than 30,000 hours) |
| Sampling flow rate | Built-in vacuum pump, 2.83L sampling |
| particle size channel | Six channels, 0.3, 0.5, 1.0, 3.0, 5.0, 10 (μm) |
| Particle size distribution error | 0.5um 5um ≤±30% |
| An indication of particle concentration error | 0.5um ≤±30% |
| detection range | 100 to 1 million |
| UCL Report | In line with Chinese GMP standards |
| sampling period | 1S - 9999999s self-set |
| Sampling Delay | 1S - 9999999s self-set |
| Sampling points | 2 - 50 points can be set arbitrarily |
| Sampling times | 2-50 times, any setting |
| Sampling area | According to requirements, any combination of letters and numbers or individually set |
| Sampling unit | Piece, Piece/m ³, Piece/FT3 and other three unit options |
| self-purification time | ≤10min |
| Operating Environment | Temperature 10 ℃ - 35 ℃ Relative Humidity ≤ 75% atmospheric pressure 86kPa - 106kPa |
| Sampling conditions | Sampling gas shall not contain acid, alkali, high temperature and other corrosion gases |
| data printing | Built-in high-speed thermal printer |
| Display mode | 5-Inch color touch screen |
| Battery Capacity | Built-in 4000mAh |
| average power consumption | 7.5W |
| Dimension | 220*230*130(W*L*H)mm |
| Weight | 2.8KG |
Factory CA-680 Dust Particle Counter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CA-680