      JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm

      Wavelength range 190nm~ 1100nm, Wavelength Precision +/- 0.4nm, Wavelength Repeatability 0.2nm, Light spectrum Bandwidth 1.7nm, Transmittance Repeatability 0.1% T, Transmittance range 0~200% T, Absorbance range -0.4~ 4A.

      Brand
      SKU: NB049257
      China jinghua
      Model
      Stock
      Loading…
      Price
      $ 2636.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • jinghua H300 Double beam Spectrophotometer of lightOverview

        • Specifications
        • Comments
        • FAQs
        H300
        Double beam Spectrophotometer of light
        • JINGHUA H300 Dual beam of light Spectrophotometer  Wavelength range 190nm-1100nm
        Wavelength range 190nm~ 1100nm, Wavelength Precision +/- 0.4nm, Wavelength Repeatability 0.2nm, Light spectrum Bandwidth 1.7nm, Transmittance Repeatability 0.1% T, Transmittance range 0~200% T, Absorbance range -0.4~ 4A.

        Introduction

        H300 dual-beam Spectrophotometer is a precision instrument used for qualitative and quantitative analysis of substances in scientific research, testing and other fields. It can accurately determine the composition and content of substances according to their absorption characteristics of different wavelengths of light.

        Features

        • The application of high-performance 1200L/mm ultraviolet special grating, coupled with the fusion of unique monochromator optical path and imported photoelectric converter, ensures the low stray light, high resolution and high luminosity linearity of the instrument.

        • The large sample chamber can be selected with a maximum of 10cm sample holder according to different requirements to meet the needs of special industries.

        • The use of imported long-life deuterium lamp and tungsten lamp ensures the high-quality requirements of the instrument for the energy of the light source, enables the instrument to be in a high stability state for a long time, enhances the reliability, and prolongs the service life of the instrument.

        • It has an advanced automatic correction of wavelength error function, which further ensures the test accuracy of the instrument. The integration of computer and host, large-screen color Chinese/English touch screen interface, with large-scale integrated circuits, makes it highly intelligent and automated, embodies the sense of science and technology, is smooth and convenient to use, and reads the relevant data and maps of the tested samples clearly and intuitively.

        • The instrument has photometric, quantitative, regression equation, kinetics, multi-wavelength, DNA/protein, peak-to-valley detection and other testing functions, and is equipped with an automatic eight-cell sample holder as standard. (This function is not available on the UV1600/UV1800)

        • The configuration of special software makes the instrument have a super memory function, which can quickly restore the test state when it is turned on again, and memorize the relevant data and spectrum curves that have been tested, so as to facilitate the export of relevant data and spectrum curves. You can also import the saved relevant data parameters and spectrum curves into the worksheet for comparison and analysis with the current test spectrum.

        • The USB interface can be equipped with a computer, printer, special software, peripherals such as keyboard or mouse, and related operating tools.

        VS

        jinghua H300 Double beam Spectrophotometer of lightSpecifications

        LIST VALUE
        Wavelength Drive automatic
        Wavelength range 190nm~1100nm
        Wavelength Precision ±0.4nm
        Wavelength Repeatability 0.2nm
        Light spectrum Bandwidth 1.7nm
        Transmittance Precision ≤ 0.3%T
        Transmittance Repeatability 0.1%T
        Transmittance Range 0~200%T
        Absorption range -0.4~4A
        Display range of concentration 0~99999
        stray light ≤ 0.05%T
        Stability ±0.0007A/h
        Baseline flatness ±0.002A
        noise 0.0005A
        output interface USB RS-232
        scan function High School Low
        dynamics have
        multi-wavelength have
        DNA/protein have
        display Large-screen color Chinese/English touch display
        Light source Imported long-life deuterium lamp/tungsten lamp

        jinghua H300 Double beam Spectrophotometer of light Packing list

        machine x1, manual x1, certificate x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +jinghua H300 Double beam Spectrophotometer of light Big data
          +jinghua H300 Double beam Spectrophotometer of lightKnowledge
          +Navigation
          jinghua
          JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm
          Service
          Focus on online sales of Lab Testing Instruments