Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Contact Angle Goniometer> Factory> Factory LX-100B Contact Angle Meter

      LX-100B Contact Angle Meter surface contact angle wetting performance table interfacial tension surface energy

      Contact angle Measurement range 0-180 °, contact angle Measurement accuracy +/- 0.1 °, syringe-specific precision syringe, capacity 500 μL, drop manual swirl/spin type liquid inlet, drop accuracy up to 0.1 μL, Maximum sample size 6 inches, stroke 60mm, accuracy 0.1mm

      Brand
      SKU: NB049274
      China Factory
      Model
      Stock
      Loading…
      Price
      $ 3149.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Factory LX-100B Contact Angle MeterOverview

        • Specifications
        • Comments
        • FAQs
        LX-100B
        Contact Angle Meter
        • LX-100B Contact Angle Meter surface contact angle wetting performance table interfacial tension surface energy
        • LX-100B Contact Angle Meter surface contact angle wetting performance table interfacial tension surface energy Figure 1
        • LX-100B Contact Angle Meter surface contact angle wetting performance table interfacial tension surface energy Figure 2
        Contact angle Measurement range 0-180 °, contact angle Measurement accuracy +/- 0.1 °, syringe-specific precision syringe, capacity 500 μL, drop manual swirl/spin type liquid inlet, drop accuracy up to 0.1 μL, Maximum sample size 6 inches, stroke 60mm, accuracy 0.1mm

        Introduction

        Contact angle refers to the tangent line of the gas-liquid interface made at the intersection of gas, liquid and solid, and the tangent angle θ between the tangent line and the solid-liquid junction line on the liquid side, and the contact angle measurement is the main method of surface performance testing today.

        The standard contact angle measuring instrument is based on the principle of optical imaging, which measures the surface contact angle, wetting performance, surface tension, surface energy and other properties of the sample surface through image profile analysis.

        apply

        Contact angle measuring instrument is widely used in various industries, in mobile phone manufacturing, glass manufacturing, surface treatment, material research, chemical industry, semiconductor manufacturing, paint and ink, electronic circuits, textile fibers, medical biology and other fields, contact angle measurement has become an important instrument to evaluate surface properties. (Some test functions need to be completed by purchasing special accessories)

        1. The wetting behavior of the liquid on the solid surface, such as spreading, penetration, and absorption, is measured by the droplet method

        2. Measurement of the advance angle, backward angle, contact angle hysteresis, rolling angle and dynamic contact angle of the material on the solid surface

        3. Continuous real-time research and process recording of absorbing materials, and analysis of contact angle curves with time

        4. Contact angle measurement of various special materials, such as powders, curved surfaces, superhydrophobic/superhydrophilic samples

        5. Attachment drop method test: Contact angle test of material immersed in liquid

        6. The hanging drop method measures the surface interfacial tension and polarity and dispersion components of various liquids

        7. Calculation of surface free energy of solids, and analysis of polar dispersion components

        8. Analyze the adhesion of liquid on solid surface, evaluate the uniformity and cleanliness of solid surface

        Principle of the device


        Factory direct LX-100B contact angle measuring instrument details Figure 1


        As shown in the figure above, the contact angle measuring instrument is mainly composed of five parts: light source, injection unit, sample stage, acquisition system and analysis software, and the equipment adopts the principle of optical imaging

        • The light source adopts dense LED cold light design, which emits uniform light, image cleaning and long life

        • The injection unit adopts a micro-manual knob type liquid feeding, which is stable and has high precision

        • The sample stage adopts a three-dimensional manual fine adjustment platform, which is flexible in operation and accurate in positioning, and the sample stage can be customized according to the actual sample size

        • The acquisition system adopts black and white imported CCD camera, shooting stability, clear image, real and reliable, the lens adopts German industrial-grade imported configuration, 0.7-4.5 times magnification adjustable, and the imaging is deformed without deformation

        • The analysis software is powerful, with one-click automatic fitting ability, and has international advanced fitting methods to meet the accurate fitting of various drop morphologies

        Comply with relevant national standards

        GB/T 24368-2009 (Detection of hydrophobic contaminants on glass surface)

        SY/T5153-2007 (Method for determining the wettability of reservoir rocks)

        ASTM D 724-99(2003) (Test Method for Surface Wettability of Paper)

        ASTM D5946-2004 (Measurement of Contact Angle of Plastic Film with Water)

        ISO15989 (Measurement of water contact angle of plastic film and sheet corona treatment film)


        VS

        Factory LX-100B Contact Angle MeterSpecifications

        LIST VALUE
        Measurement range of contact angle 0~180°
        Measurement Accuracy of contact angle ±0.1°
        syringe Special precision syringe, Capacity 500μL
        Dripping method Manual swirl/spin feed, drop Accuracy up to 0.1 μL
        Injection unit movement Up and down 100mm; left and right 100mm
        Table size 130mm*150mm
        Maximum sample size He is a size six.
        Sample stage movement Move back and forth, manual, stroke 60mm, Accuracy 0.1mm move around, manual, stroke 35mm, Accuracy 0.1mm move up and down, manual, stroke 80mm, Accuracy 0.1mm
        Dimension 550*196*485mm
        Weight 11KG
        Power supply Voltage 220V/60HZ
        Light source Dense LED Adjustable Blue Color Industrial Cold Light source
        lifespan The service life is more than 25,000 hours
        Dynamic contact angle fitting Batch screenshot fitting, video continuous automatic fitting, automatic online real-time fitting
        Table/interfacial tension test Hanging drop method (real-time fully automatic dynamic surface tension test)
        Test droplet status Pendant Drop, Sessile Drop (2/3 state), Bubble Capture, Seat Drop, Seat Needle
        CCD camera SONY original imported high-speed industrial-grade chip, 25 frames/S, 130W pixels
        lens 0.7-4 High Definition Industrial Continuous Zoom Microscope
        Acquisition system adjustment Front and rear 60mm, adjustable Viewing Angle (head-up, 360 ° swirl/spin and other multi-Viewing Angle)

        Factory LX-100B Contact Angle Meter Packing list

        host X1, manual X1, certificate X1, warranty card X1, software X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What should I pay attention to when measuring the contact angle of powder materials? Can this device measure?
        [A]
        Can be measured, but need to buy powder test Accessories. When measuring the powder to form a flat surface, the instrument's manual three-dimensional platform can precisely adjust the position, 130W pixel high definition CCD can clearly capture the droplet profile, to ensure the measurement accuracy of this special sample of powder.
        [Q]
        We need to study the spreading process of the coating on the metal surface. Can this instrument record it dynamically?
        [A]
        Yes! This instrument supports dynamic contact angle measurement and real-time process recording. You can capture the spread and penetration behavior of Coating droplets on the metal surface through the video continuous automatic fitting function, and generate contact angle changes over time. Linear dispersion helps you quantify and analyze Coating wetting performance and adhesion effect.
        +Factory LX-100B Contact Angle Meter Big data
          +Navigation
          Factory
          LX-100B Contact Angle Meter surface contact angle wetting performance table interfacial tension surface energy
          Service
          Focus on online sales of Lab Testing Instruments