BOSEAN BH-90 Portable Gas Detector Combustible Gas Detector
Detection gas can be gas, range 0-100% LEL, resolution 1% LEL, Sampling method diffusion type, Response time T90 < 60s, shell material ABS, Working time > 8h continuous, Environmental temperature: -10 ℃~ 55 ℃; Humidity: 0-95% RH (non-condensing).
Bosean-
GUOYUGRA GY/VGD-200-F2-G (0-20ppm) Fluorine Detector
$ 568.00 -
BH-60-HCN (with display + alarm) Fixed HCN Gas Detector 0~10ppm
$ 257.00 -
Empaer AASD-H2S Lightning series handheld hydrogen sulfide Detector
$ 267.00 -
GUOYUGRA GY/VGD-200-Ex-G (0-1000ppm) Combustible Gas Detector (IR)
$ 817.00 -
Empaer AATL-CL2 Pathfinder Series Stationary Chlorine Detector
$ 389.00
Introduction
This portable Gas Detector (hereinafter referred to as the Detector) is an intelligent Gas Detector designed by using advanced large-scale integrated circuit technology, international standard intelligent technology level design technology and proprietary digital and analog hybrid communication technology. The Detector uses natural diffusion to detect gas, and the sensitive element adopts high-quality gas sensor, which has excellent sensitivity and excellent repeatability, and is easy to use and maintain, which greatly meets the requirements of high reliability of equipment for industrial site safety monitoring. The shell is made of high-strength engineering plastics and composite anti-slip rubber, which has high strength, good hand feel, and is waterproof, dustproof and explosion-proof.
Application
This Detector is widely used in petroleum, chemical, environmental protection, metallurgy, refining, gas transmission and distribution, biochemical medicine, agriculture and other industries.
standard
The design, manufacture and verification of this product comply with the following national standards,
GB3836.1-2010 "Explosive atmospheres Part 1: General requirements for equipment"
GB12358-2006 "General Technical Requirements for Workplace Ambient Gas Detection and Alcellors"
GB3836.4-2010 "Explosive atmospheres Part 4: Equipment protected by intrinsically safe type "i"
Bosean BH-90 Gas Detector portableSpecifications
| LIST | VALUE |
|---|---|
| Detect gas | combustible gas |
| resolution | 1%LEL |
| Sampling method | diffusion |
| Response time | T90<60s |
| Shell material | ABS |
| Power Supply | 3.7V rechargeable lithium battery (1500mAh) |
| Working time | > 8h continuous |
| Alarm mode | Sound, light, vibration. |
| Instruction method | LCD Display Real-time Data and System Status Light Emitting Diode, Sound, Vibration Indication Alarm, Fault and UnderVoltage |
| Weight | About 130g |
| Explosion-proof sign | Ex ib IIB T3 Gb |
| Operating Environment | Temperature: -10 ℃~ 55 ℃; Humidity: 0-95% RH (non-condensing) |
| Mass Assurance | One year quality assurance period, free maintenance during the warranty period. |
Bosean BH-90 Gas Detector portable Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


BH-90