DDKSIC EC100 Laboratory Conductivity Meter conductivity/resistivity/TDS/salinity/℃
EC100 Benchtop Conductivity Meter, reference temperature: 18 ℃, 20 ℃, 25 ℃ optional, measurement can be switched to TDS/salinity/resistivity, with power failure protection and factory reset function.
DDKSIC-
FANGZHOU DDS-609 high-precision module Conductivity Meter
$ 870.00 -
BANTE A150-DL Laboratory conductivity /TDS/salinity/resistivity meter
$ 657.00 -
Bante540-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids
$ 422.00 -
LEICI DJS-0.01C Type Titanium Alloy Conductivity Detector electrode Three-core aviation plug
$ 204.00 -
LEICI DDB-303A high-precision Conductivity Meter conductivity /TDS/temperature 1.0 class
$ 319.00
Features
Measurement parameters: conductivity, resistivity, TDS, salinity, °C
High-definition resolution LCD customized screen, beautiful, clear and easy to operate
Intelligent operating system, with electrode management, parameter setting and other functions, and stable reminder of measured values
It supports automatic temperature compensation and electrode diagnosis
The calibration supports the calibration of the electrode constant and the calibration of the solution
Data storage: 450 groups (number, value, unit, temperature, time)
Data printing: Bluetooth connection to the printer, direct printing results (printer PR01 optional)
Data output: U disk/printer
Dustproof and waterproof rating: IP54
DDKSIC EC100 Laboratory Conductivity MeterSpecifications
| LIST | VALUE |
|---|---|
| Conductivity level | Level 1.0 |
| Measurement range of conductivity | 0~200.0mS/cm Automatic segmentation: 0~19.999us/cm; 20.0~199.9uS/cm; 200~1999us/cm2.00~19.99mS/m; 20.00~199.9ms/cmTDS: 0~100.0g/L (coefficient adjustable) Resistivity: 5.000Ω · cm~ 100.0MΩ · cm salinity: (0.00~100.00) ppt |
| Conductivity calibrating point | 1 point |
| EC resolution | 0.001 |
| Conductivity automatic temperature compensation range | (0.0~50.0)°C/(32.0~122.0)°F |
| Conductivity Accuracy | ±1.0%FS |
| Measurement range | (-9.9~130.0)°C/(14.1~266.0)°F |
| Measurement Accuracy | ±0.2°C |
| Data output | U disk/printer |
| Power Supply | DC120V |
| Measurement parameter | Conductivity, resistivity, TDS, salinity, ℃ |
DDKSIC EC100 Laboratory Conductivity Meter Packing list
Host, CON201T plastic case ATC Conductivity detector electrode, line length: 1 meter, K = 1.0, conductivity standard solution: 50mL 146.6 μS/1408μS/12.85mS/cm 1 bottle each, F 10,000 electrode holder: 1 set, A01 power adapter: 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


EC100