DDKSIC CD100 desktop conductivity, Dissolved Oxygen Meter conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/℃
CD100, with power-off protection and factory reset function, Data storage: 450 groups (number, value, unit, temperature, time).
DDKSIC-
LEICI 780800N02 residual chlorine/total chlorine kit for DGB-402A/402F/403F/424
$ 117.00 -
HANNA HI76483A/P special PTFE dissolved oxygen membrane
$ 262.00 -
LEICI DGB-428 Optoelectronic Colorimetry Water Quality Analyzer Water Hardness Urea
$ 521.00 -
HANNA HI93711-01 Photometer reagent total chlorine 100 times
$ 138.00 -
JINGQI WD8103 Nitrate Tester
$ 481.00
Features
Measurement parameters: conductivity, resistivity, TDS, salinity, dissolved oxygen concentration, dissolved oxygen saturation, °C
High-definition resolution LCD customized screen, beautiful, clear and easy to operate
Intelligent operating system, with electrode management, parameter setting and other functions, and stable reminder of measured values
It supports automatic temperature compensation and electrode diagnosis
Conductivity calibration supports cell constant calibration and solution calibration.
Temperature compensation, barometric pressure compensation: automatic
Salinity compensation: Manual
Data storage: 450 groups (number, number, unit, temperature, time)
Data printing: Bluetooth connection to the printer, direct printing results (printer optional)
Data output: U disk/printer
Dustproof and waterproof rating: IP54
DDKSIC CD100 Desktop conductivity, Dissolved Oxygen Meter (button type)Specifications
| LIST | VALUE |
|---|---|
| Conductivity level | Level 1.0 |
| Measurement range of conductivity | 0~200.0mS/cm Automatic segmentation: 0~19.999us/cm; 20.0~199.9uS/cm; 200~1999us/cm2.00~19.99mS/m; 20.00~199.9ms/cmTDS: 0~100.0g/L (coefficient adjustable) Resistivity: 5.000Ω · cm~ 100.0MΩ · cm salinity: (0.00~100.00) ppt |
| Conductivity calibrating point | 1 point |
| EC resolution | 0.001 |
| Conductivity automatic temperature compensation range | (0.0~50.0)°C/(32.0~122.0)°F |
| Conductivity Accuracy | ±1.0%FS |
| Dissolved oxygen DO Measurement range | (0.00~20.00)mg/L |
| Dissolved oxygen DO Accuracy | ±0.30 mg/L |
| Dissolved oxygen saturation | (0.0~200.0)% |
| Dissolved oxygen DO pressure compensation: automatic | (0~200.0)kPa |
| Dissolved oxygen DO automatic temperature compensation range | (0.0~50.0)°C/(32.0~122.0)°F |
| Dissolved oxygen DO salinity compensation: manual | 0~45Pt Manual |
| Measurement range | (-9.9~130.0)°C/(14.1~266.0)°F |
| Measurement Accuracy | ±0.2°C |
| Data output | U disk/printer |
| Power Supply | DC120V |
| Measurement parameter | Conductivity, resistivity, TDS, salinity, dissolved oxygen concentration, dissolved oxygen saturation, ℃ |
DDKSIC CD100 Desktop conductivity, Dissolved Oxygen Meter (button type) Packing list
Host, CON201T molded case ATC Conductivity detector electrode, line length: 1 m, K = 1.0, DO01-2M dissolved Oxygen electrode (polarographic type), line length: 2 m, conductivity standard solution: 50mL 146.6 μS/1408μS/12.85 mS/cm 1 bottle each, DOS-01 dissolved oxygen solution: 30mL, 1 bottle, DOSC dissolved oxygen diaphragm cap: 3/group, 1 group, F 10,000 electrode holder: 1 set, A01 power adapter: 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CD100