Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> DDKSIC> DDKSIC PC1 Pen multiparameter analyzer

      DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃

      pH resolution 0.1/0, pH Accuracy +/- 0.01pH +/- 1 word, ORP resolution 0.1, ORP Accuracy +/- 0.1% F. S +/- 1 word, conductivity level 1.0, conductivity Measurement range 0~19.99mS/cm, automatic segmentation, Temperature Measurement accuracy +/- 0.2 ° C.

      Brand
      SKU: NB049450
      China DDKSIC
      Model
      Stock
      Loading…
      Price
      $ 215.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DDKSIC PC1 Pen multiparameter analyzerOverview

        • Specifications
        • Comments
        • FAQs
        PC1
        Pen multiparameter analyzer
        • DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃
        • DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃ Figure 1
        • DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃ Figure 2
        pH resolution 0.1/0, pH Accuracy +/- 0.01pH +/- 1 word, ORP resolution 0.1, ORP Accuracy +/- 0.1% F. S +/- 1 word, conductivity level 1.0, conductivity Measurement range 0~19.99mS/cm, automatic segmentation, Temperature Measurement accuracy +/- 0.2 ° C.

        Introduction

        • Measurement parameters: pH, mV (ORP electrode optional), conductivity, resistivity, TDS, salinity, °C

        • Combined electrode (pH/conductivity/TDS/salinity/temperature can be measured at the same time, and different parameters can be easily switched with one key)

        • Multi-color backlit display

        • Reading Stabilization Reminder; Automatic data locking; Low Voltage display

        • Conductive electrode: platinum black plating to reduce the polarization effect of high range and improve measurement accuracy

        • The electrodes are replaceable, and the package includes a standard solution and a lanyard

        • CH/USA/NIST solution calibration optional

        • Function settings: TDS conversion coefficient, reference temperature, temperature compensation coefficient, auto shutdown time, background light display time, data lock, etc

        • Dustproof and waterproof rating: IP67

        VS

        DDKSIC PC1 Pen multiparameter analyzerSpecifications

        LIST VALUE
        pH level 0.01 level
        Measurement range of pH (-2.00~16.00)pH
        pH resolution 0.1/0.01
        pH Accuracy +/- 0.01pH +/- 1 word
        pH calibrating point 1~ 3 point Automatic calibration
        pH temperature automatic compensation (0.0~60.0)°C/(32.0~140.0)°F
        ORP Measurement range (-1000.0~+1000.0)mV
        ORP resolution 0.1
        ORP Accuracy +/- 0.1% F. S +/- 1 word
        Conductivity level Level 1.0
        Measurement range of conductivity 0~19.99mS/cm, automatic segmentation: 0~19.99uS/cm; 20.0~199.9uS/cm; 200~1999uS/cm; 2.00~19.99mS/cmTDS: 0.0mg/L-10.0g/L (coefficient adjustable) Resistivity: 50Ω · cm~ 20MΩ · cm salinity: 0~10.0ppt
        EC resolution 0.01/0.1/1
        Conductivity Accuracy +/- 1.0% +/- 1 word
        Measurement range (0.0~60.0)°C/(32.0~140.0)°F
        Measurement Accuracy ±0.2°C
        Measurement parameter pH, mV (ORP electrode optional), conductivity, resistivity, TDS, salinity, ℃

        DDKSIC PC1 Pen multiparameter analyzer Packing list

        Host (built-in AAA dry battery 4), pH buffer solution: 30mL pH4.1 bottle each, conductivity standard solution: 30mL 1408μS/12.85mS/cm 1 bottle each, 3mol KCl electrode soaking solution: 10mL, 1 bottle, sample bottle: 30mL 4, lanyard: 1, suitcase: 1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +DDKSIC PC1 Pen multiparameter analyzer Big data
          +Navigation
          DDKSIC
          DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃
          Service
          Focus on online sales of Lab Testing Instruments