Huicheng HCDR-P Plate Thermal Conductivity Instrument Temperature resolution 0.01 ℃
Thermal conductivity range 0.0020~2.0000 W/(m · K), resolution 0.0001 W/(m · K), Hot Plate Temperature range RT + 10~100 ℃, Cold Plate Temperature range RT~ 80 ℃, Hot Plate temperature control accuracy +/- 0.02 ℃, Temperature resolution 0.01 ℃, thickness resolution 0.01mm
HuiCheng-
Vacuum drying ZY-KGZ-2 pattern rapid drying, box vacuum heating
$ 2527.00 -
Zibo Coulomb KRH-2 oil and synthetic liquid anti-emulsification performance Tester
$ 1314.00 -
Huicheng DSC-600S Differential Scanning Calorimeter FTC and STC Dual Mode 600 ℃
$ 5481.00 -
CHINA NBC-UWL11A Ultrasonic metal spot welding machine 40KHz
$ 7533.00 -
Jingyi JY-30A3 automatic forward and reverse swirling/spinning oil mixer
$ 2527.00
Key features:
The full temperature control system adopts the optimized dynamic PID algorithm, which greatly avoids the shortcomings of the traditional PID algorithm and improves the stability of temperature control.
The power platform adopts the soaking structure process, which effectively ensures the uniformity of surface temperature and higher heating efficiency.
The sample tray has a one-button control function, and both the upper and lower computers can realize the automatic operation of the mechanical structure in the tank, which is more convenient to control.
The instrument has a built-in high-precision laser distance sensor, which has the function of automatically measuring the thickness of the sample, making the test more accurate and efficient.
The instrument has a built-in miniature pressure sensor, which can perform a detailed pressure test on the sample to meet different test pressure needs.
With a friendly man-machine interface, the instrument is equipped with a 7-inch LCD touch screen, which can control the entire test system through the touch screen, and the cold and Hot Plate temperatures, sample pressure, thickness and other parameter values can be intuitively observed and displayed by the LCD screen.
The software has a two-way communication function, and any parameters required for the sample experiment can be set on the software, that is, the entire experimental process can be completed through the operation software, making the experiment more intelligent.
The instrument has a highly automated computer data communication and intelligent analysis and processing system, and the software can record the experimental data of the sample in real time, and automatically analyze the experimental results after the end.
HuiCheng HCDR-P Flat plate thermal conductivity meterSpecifications
| LIST | VALUE |
|---|---|
| Thermal conductivity range | 0.0020~2.0000 W/(m·K) |
| resolution | 0.0001 W/(m·K) |
| Thermal resistance range | 0.02~4 (m2·K)/W |
| Hot Plate Temperature range | RT+10~100℃ |
| Temperature range of cold plate | RT~80℃ |
| Hot Plate temperature control Accuracy | ±0.02℃ |
| Temperature Resolution | 0.01℃ |
| Measurement Accuracy | ±3% |
| Repeatability | ±1% |
| Thickness resolution | 0.01mm |
| Thickness range | 1~ 50Mm automatic measurement |
| Pressurization method | Automatic pressurization |
| Pressure resolution | 0.1Kpa |
| Pressure range | 0~4Kpa automatically adjustable |
| Sample size | 300mm×300 mm×(5-50 mm) |
| Interface | Standard USB port |
| reference standard | GB/T 10294ASTM C177ISO 8302 |
HuiCheng HCDR-P Flat plate thermal conductivity meter Packing list
machine x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HCDR-P