DSC400 Differential Scanning Calorimeter RT-600 ℃
Using imported E-type Sensors, with ultra-high sensitivity (0.001mW) and Accuracy (0.001 ℃), temperature range RT-600 ℃, can accurately determine the melting point, Glass transition temperature, specific heat capacity and other parameters.
DaZhan equipment-
Huicheng DSC-600L/-170~600 Differential Scanning Calorimeter -170 ℃~ 600 ℃
$ 9802.00 -
TQC DV50010 Immersion Valve Body 100ml
$ 2118.00 -
YINUO YN-CP01 Sheet Former, diameter 200 drying non-drying optional
$ 12134.00 -
Huicheng HCDR-P Plate Thermal Conductivity Instrument Temperature resolution 0.01 ℃
$ 5978.00 -
CHINA NBC-DB-501B DuPont Impact Tester 1m
$ 899.00
Product Introduction
DZ-DSC400 is a high-precision differential scanning calorimeter launched by the company, the sensor is made of imported material E-couple, high accuracy, high sensitivity, good repeatability, signal acquisition circuit with shielding protection, strong anti-interference, high baseline stability and repeatability.
DZ-DSC400 differential scanning calorimeter can be used to test glass transition temperature, phase transition temperature, melting point, enthalpy value, curing temperature and product stability, specific heat capacity, crystallization, oxidation induction period, etc. It can be competent for the research of pipes, polymers, chemicals, food and many other fields, and the products serve universities, enterprises, scientific research institutes and quality inspection institutions, etc., with a wide range of applications to meet the testing needs of various industries.
Technical features:
1. Industrial-grade 7-inch touch screen with rich display information
2. Brand new furnace structure, better baseline and higher precision. The heating adopts indirect conduction mode, which has high uniformity and stability, reduces pulse radiation, and is better than the traditional heating mode.
3. USB communication interface mode, strong versatility, reliable and uninterrupted communication, support self-recovery connection function.
4. Automatically switch between two channels of atmosphere flow, fast switching speed and short stability time. At the same time, a shielding gas input is added.
5. The software is rich in functions and covers the corresponding test case database
6. Ultra-high sensitivity, accuracy, 0.001MW

Meets standards
GB/T 33466.1-2016 Rigid polyvinyl chloride pipes -- Differential scanning calorimetry (DSC) Part 1: Measurement of processing temperature
GB/T 40271-2021 Test methods for textile fiber identification -- Differential scanning calorimetry
GB/T 19466.1-2004 Plastics – General principles for differential scanning calorimetry (DSC).
GB/T 19466.4-2016 Plastics – Differential scanning calorimetry (DSC) – Part 4 - Determination of specific heat capacity
GB/T 19466.5-2022 Plastics – Differential scanning calorimetry (DSC) – Part 5: Determination of characteristic reaction curves temperature, time, reaction enthalpy and conversion rate
GB/T 19466.6-2009 Plastics – Differential scanning calorimetry (DSC) – Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).
GB/T 19466.2-2004 Plastics – Differential scanning calorimetry (DSC) – Part 2: Determination of glass transition temperature
GB/T 19466.3-2004 Plastics – Differential scanning calorimetry (DSC) – Part 3: Determination of melting and crystallization temperature and enthalpy
GB/T 29611-2013 Determination of glass transition temperature of raw rubber (part of the national standard display)
DaZhan equipment DSC400 Differential Scanning CalorimeterSpecifications
| LIST | VALUE |
|---|---|
| temperature range | RT-600℃ |
| DSC range | ±1000mw |
| Temperature sensitivity | 0.001℃ |
| Heating rate | 0.1~100℃/min |
| Cooling rate | 1~20℃/min(550℃~100℃) |
| DSC sensitivity | 0.001mw |
| Frequency of data collection | Data collection frequency can be set by yourself, acquisition frequency range (0.1~ 50Hz) |
| Temperature control method | PID precise control (automatic program control); the lower computer interface can set and define the PID parameter value by itself to meet different environments and power heating; the initial heating power can be customized |
| Chill down | air cooling |
| Flowmeter | Float flowmeter, range 0~200ml/min (optional Mass flowmeter module, Accuracy 0.1ml/min) |
| Enthalpy Accuracy | ±0.5% |
| Atmosphere device | Built-in two-way gas, can pass nitrogen, oxygen, air, carbon dioxide, argon, etc |
| atmosphere setting | The instrument can set the initial atmosphere emptying before the experiment, and the emptying time of inert gas can be set; after the emptying, the instrument will run automatically, and the instrument interface and software can be set in both directions |
| sensor type | E type |
| Sensors process | Thermal diffusion process |
| Furnace body process | Anti-corrosion and anti-oxidation treatment |
| operating software | Experiments can be exported in EXECL format, PDF format, etc.; the software has automatic analysis function, which can analyze specific heat Capacity, enthalpy, melting point, Glass transition temperature, curing degree, crystallization, oxidation induction period, etc.; the software has a database of standard test methods; the software can compare more than 10 sets of data at the same time |
| Program settings | ≥ 50 segments, can be expanded |
| comparison function | You can compare the master standard and set a reasonable error value; if the error value is exceeded, the comparison prompt is unqualified |
DaZhan equipment DSC400 Differential Scanning Calorimeter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


DSC400