DZ-TGA201 Thermal Gravimetric Analyzer RT +~ 1250 ℃
Ultra-wide temperature range (room temperature to 1250 ° C), 0.1 μg high-resolution weighing system, PID precise temperature control (supports multi-stage rise/drop and thermostatic), three-way gas flow control, and fast cooling design (1000 ° C to 50 ° C ≤ 20 minutes).
DaZhan equipment-
Huicheng TGA-601/1250 Thermal Gravimetric Analyzer TG TGA 1250 ℃
$ 9149.00 -
DZ-TGA201 Thermal Gravimetric Analyzer RT +~ 1250 ℃
Login -
Huicheng TGA-605/1550 Thermal Gravimetric Analyzer TG TGA 1550 ℃
$ 14124.00 -
DZ-TGA103 Thermal Gravimetric Analyzer RT +~ 1350 ℃
Login -
DZ-TGA101 Thermal Gravimetric Analyzer Precious Metal Alloy Wire Double Row Winding Heating
Login
The working principle of thermogravimetric analyzer (TGA) is based on temperature programming, which measures the mass of a substance as a function of temperature or time. Its main components include a furnace, a balance, a temperature controller and a recording system.
Operating Principle
Heating process: The sample is placed in a crucible inside the furnace and heated or cooled at a certain rate by means of a programmed temperature control system. In this process, the sample undergoes a series of physical and chemical changes, such as water evaporation, organic decomposition, phase transition, etc., which can lead to a reduction in the mass of the sample.
Quality monitoring: The mass change of the sample is measured and recorded in real time by a high-precision balance. The balance converts the change in mass into an electrical signal, which is transmitted to the recording system, and finally shows the mass as a function of temperature or time in the form of a curve.
Data recording and analysis: The thermal stability, phase change temperature, decomposition temperature and other characteristics of the sample can be analyzed through the mass change curve recorded by the recording system.
Fields of application
It is widely used in research and development, process optimization and quality control in various fields such as plastics, rubber, coatings, catalysts, inorganic materials, metal materials and composite materials.

Structural advantages
1. The furnace body is heated by double-row winding of precious metal platinum rhodium alloy wire, which reduces interference and is more resistant to high temperature.
2. The pallet sensor is made of precious metal alloy wire, which has the advantages of high temperature resistance, oxidation resistance, corrosion resistance and so on.
3. The power supply, circulating heat dissipation part and the host are separated, reducing the influence of heat and vibration on the micro-thermal balance.
4. The main engine is used to isolate the thermal influence of the heating furnace on the chassis and the microthermal balance.
5. The furnace body adopts double insulation, and the linearity is better; The furnace body is automatically lifted and lowered, which can quickly cool down; With exhaust gas outlet, it can be used in conjunction with infrared

Controller, software advantages
1. Imported ARM processor, sampling speed, processing speed is faster.
2. Four-channel sampling AD collects TG signal and temperature T signal.
3. Heating control, using PID algorithm, precise control. It can be heated and kept constant in multiple stages
4. USB two-way communication is used between the software and the instrument, which fully realizes remote operation, and the parameter setting of the instrument and the operation stop of the instrument can be carried out through the computer software.
5. 7 inch full-color 24bit touch screen, better man-machine interface. The calibration of the TG is possible on the touch screen
Comply with industry standards
ASTM D 3386 ; ASTM D 696 ; ASTM E831-2019 ; ASTM E831-06 ; ASTM E831-2014 ; DIN 51045-3-2009 ; GB/T 33047.3-2021 ; GB/T 4498.2-2017 ; GB/T 32868-2016 ; GB/T 31984-2015 ; GB/T 14837.2-2014 ; GB/T 29189-2012等.
DaZhan equipment DZ-TGA201 Thermal Gravimetric AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| temperature range | Room temperature -1250 ℃ |
| Temperature Resolution | 0.001℃ |
| Temperature Fluctuation | ±0.01℃ |
| Weighing system Measurement Range | 0.001Mg~ 3g, can be expanded to 50g |
| Accuracy | 1ug |
| resolution | 0.1ug |
| atmosphere control | Three-way gas flow control |
| software | Intelligent software can automatically record TG Linear dispersion for data processing, TG/DTG, Mass, percentage coordinates can be switched arbitrarily; software with automatic adjustment function, according to the map display, automatic extension, zoom |
| Thermostatic time | Arbitrary setting; standard configuration ≤ 600min |
| operating software | There is a corresponding copyright Certificate, and the data test frequency can be selected in real time, 2S, 5S, 10S, etc |
| Lifting furnace body | The furnace body adopts water-cooled and dust-free circulation to chill down, which can provide accurate temperature control mode for measurement in a variety of dynamic and static atmospheres; optional with a variety of different temperature ranges and different characteristics of freely replaceable Sensors can be configured with a variety of different types of crucible to adapt to different sample characteristics. 1000 ℃ -50 ℃ ≤ 20min (air cooling + water circulation) |
| Water cooling device | External water cooling device to isolate the effect of heat on the drift of the weighing system; temperature range -10~60 ℃ |
DaZhan equipment DZ-TGA201 Thermal Gravimetric Analyzer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 45939-2025
- ActiveGB/T 19469-2004
- ActiveGB/T 27762-2011
- ActiveGB/T 27761-2011
- ActiveGB/T 14837.1-2014
- ActiveGB/T 33047.1-2016
- ActiveGB/T 34916-2017
- ActiveGB/T 35930-2018
- ActiveGB/T 14837.3-2018
- ActiveGB/T 33047.3-2021
- ActiveGB/T 33047.2-2021
- ActiveGB/T 38216.3-2023
- ActiveGB/T 11842-2025
- IncomingGB/T 32868-2025
- ActiveASTM ASTM E2551-20
- ActiveGB/T 44307-2024
- ActiveSN/T 5271-2019
- ActiveSN/T 3116-2012
- ActiveGB/T 29189-2012
- ActiveGB/T 4498.2-2017


DZ-TGA201