QIWEI QW-NSY-12ST (timing) sample condensing instrument, air drying instrument 12 holes PID temperature control
Timing, 12-hole independent blowpipe design to avoid cross-contamination, PID temperature control accuracy +/- 0.3 ℃, with its own air source to achieve 0-36L/min Flow rate adjustment, compact body suitable for a variety of environments.
QiWei-
CHINA NBC-YX-2010 Manual two-dimensional image Measurement Instrument 200 × 100mm
$ 2660.00 -
KOSON KS-75S intelligent in-situ double shear instrument, masonry Detector 75KN thrust, Bluetooth printing
$ 837.00 -
Smart Sensor ST5750A Electronic Manifold Meter, Refrigerant Meter
$ 246.00 -
LANDTEK GS-100DA Gaussian meter, Tesla meter, Gaussian meter
$ 264.00 -
YUZHOU PG-1 metallographic sample polishing machine, large throwing plate, low noise
$ 267.00
Product Introduction
apply
Sample preparation in sample processing, fluid extraction analysis. Sample concentration is performed by blowing air into the surface of the heated sample.
peculiarity
This method has the characteristics of time-saving, easy operation and easy control, and can quickly obtain the expected results.
The sample concentrator adopts a dry constant temperature bath as the heating source, which has good heat transfer and uniform heat transfer, which is conducive to rapid heating and rapid temperature control. Air is blown onto the surface of the sample for rapid concentration of liquid samples. The blowpipes are independent of each other and do not cause cross-contamination.
The product comes with an air source, compact and easy to carry, equipped with PID LCD display control instrument, high definition display, light indicator button, with temperature control function (optional temperature and timing function control instrument is the timing model), suitable for rapid concentration of samples in any environment.
Schematic diagram of the product structure

QiWei QW-NSY-12ST (timing) Sample condenser (air dryer)Specifications
| LIST | VALUE |
|---|---|
| number of holes | 12 holes |
| hole depth | 45mm |
| gas source | air source |
| diameter | 16mm(±0.3mm) |
| temperature error | ≤±0.3℃ |
| Flow rate | 0―36L/ min |
| security | Intrinsically safe for organic solvents |
| Maximum Power | 250W |
| Temperature range | Room temperature + 5 ℃ - 100 ℃ |
| Box size | Length 32 × 22 × 28cm |
QiWei QW-NSY-12ST (timing) Sample condenser (air dryer) Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


QW-NSY-12ST (timing)