Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> DongRu> DongRu DR120 Coating Thickness Gauge

      DONGRU DR120 Coating Thickness Gauge

      DONGRU DR120 Coating Thickness Gauge for nondestructive measurement of the thickness of nonmagnetic coatings on magnetic metal substrates (e.g. steel, iron, nickel) (e.g. paints, Electrophoresis, enamel, rubber, powder, enamel, corrosion protection, galvanized, chromium, etc.)

      Brand
      SKU: NB005061
      China DongRu
      Stock
      Loading…
      Price
      $ 167.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • DongRu DR120 Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        DR120
        Coating Thickness Gauge

        The DR120 coating Thickness Gauge adopts the principle of electromagnetic induction, and according to the national industry: GB/T4956-2003 standard, it can quickly, without damage, and accurately measure the thickness of the coating on the magnetic metal surface. It can non-destructively measure the thickness of non-magnetic coatings (such as: paint, electrophoresis, enamel, rubber, powder, enamel, anti-corrosion layer, galvanized, chrome, etc.) on magnetic metal substrates (such as: steel, iron, nickel); DR120 The integrated coating Thickness Gauge is exquisite and compact, and uses a metal measuring head to make the on-site test more stable and firmer.

        This instrument can be widely used in the detection fields of automobile paint, automobile evaluation, manufacturing, metal processing, chemical industry, commodity inspection and so on.

        Features

        A. Using alloy integrated probe

        B. Simple operation, fast test speed and high sensitivity

        C. Exquisite ergonomic integrated design, easy to carry

        D. Two test methods: continuous test (CONT INUE) and single (SINGLE) measurement

        E. Statistical function: maximum value (MAX), minimum value (MIN), average value (MEA)

        F. It can store 2000 measurement data (10 sets of data)

        G. It can be connected to a computer for communication and read out stored data for saving or printing (optional)

        H. Two calibration methods: zero point calibration and two point calibration

        I. There is a buzzer prompt during the operation (single measurement mode)

        I. Automatic identification of iron-based and non-ferrous-based substrates

        J. Low Voltage indication

        K. Manual/automatic shutdown function

        L, super large LCD backlight display, with screen rotation and inversion function

        M, metric and imperial conversion function um/mil


        VS

        DongRu DR120 Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction
        Measurement range 0 ~ 1500m
        margin of error ± (3% + 1.5µm)
        Resolution 0.1µm
        Minimum measurement surface 18*15mm
        Minimum radius of curvature Convex: 5mm; Concave: 25mm
        thinnest matrix 0.4mm
        Calibrated mode Zero calibrated, two calibrated
        Measurement mode Continuous test (CONT INUE) and single (SINGLE) measurement methods
        Unit display one / thousand
        Statistical function MAX Maximum (MAX), MIN Minimum (MIN), Average (MEA)
        data storage 2000 measurements
        Power Three (7) alkaline batteries
        Standards GB/T4956-2003
        Total Weight 106G (without battery)

        DongRu DR120 Coating Thickness Gauge Packing list

        host with probe x1, calibrated diaphragm x4, iron substrate x1, ABS instrument case x1, No. 5 battery x2, manual x1, certificate x1, cleaning cloth x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the effect of the screen backlight function of the DR120 Coating thickness gauge?
        [A]
        The screen backlight function ensures that the measurement results on the screen can be clearly read even if the rays of light are insufficient.
        [Q]
        Is the screen swirl/spin inversion function supported on the LCD screen of the instrument?
        [A]
        Yes, the LCD display of the DR120 has a screen swirl/spin inversion function, which can be adjusted as needed.
        [Q]
        Does this instrument support conversion between metric and British units?
        [A]
        Yes, the DR120 supports conversion between metric and British units, meeting users' needs in different regions.
        [Q]
        What are the Measurement modes of DR120 Coating thickness gauge?
        [A]
        Measurement modes: Continuous Test (CONTINUE) and Single Measurement (SINGLE) to meet different measurement needs.
        [Q]
        What is the function of the instrument's low voltage indicator?
        [A]
        The low voltage indicator can remind the user to replace the battery in time to ensure the normal operation of the instrument.
        DongRu
        DONGRU DR120 Coating Thickness Gauge
        Service
        Focus on online sales of Lab Testing Instruments