Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermogravimetric Analyzer> HuiCheng> HuiCheng TGA-605S Thermal Gravimetric Analyzer
      HuiCheng TGA-605S Thermal Gravimetric Analyzer

      Huicheng TGA-605S Thermal Gravimetric Analyzer Built-in imported Balance ceramic furnace body, dual temperature sensor Temperature range Room temperature to 1550 ℃

      Built-in imported mass weighing Balance, with its own calibrating and temperature compensation, mass resolution of 0.01mg. The closed ceramic insulation furnace body and dual temperature sensor design improve signal sensitivity and temperature control accuracy, support FTC and STC two experimental modes and 12-order program temperature control.

      Brand
      SKU: NB051096
      China HuiCheng
      Stock
      Loading…
      Price
      $ 16210.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HuiCheng TGA-605S Thermal Gravimetric AnalyzerOverview

        • Specifications
        • Comments
        • FAQs
        TGA-605S
        Thermal Gravimetric Analyzer
        • Huicheng TGA-605S Thermal Gravimetric Analyzer Built-in imported Balance ceramic furnace body, dual temperature sensor Temperature range Room temperature to 1550 ℃
        Built-in imported mass weighing Balance, with its own calibrating and temperature compensation, mass resolution of 0.01mg. The closed ceramic insulation furnace body and dual temperature sensor design improve signal sensitivity and temperature control accuracy, support FTC and STC two experimental modes and 12-order program temperature control.

        Instrument introduction

        Thermogravimetric analysis (TG, TGA) is to observe the change of the mass of a sample with temperature or time during the process of heating, constant temperature or cooling, with the aim of studying the thermal stability and composition of the material. It is widely used in research and development, process optimization and quality control in various fields such as plastics, rubber, coatings, catalysts, inorganic materials, metal materials and composite materials.

        Instrument use

        The following properties of materials are measured and studied: thermal stability, decomposition process, adsorption and desorption, oxidation and reduction, quantitative analysis of components, effects of additives and fillers, moisture and volatiles, reaction kinetics, etc.

        Key features:

         1. Built-in imported mass weighing balance, with internal calibration and temperature compensation functions, can respond quickly to quality changes, with better accuracy and repeatability;

         2. The instrument has a built-in mass level guidance function, and the change of sample position does not affect the quality result within the scale range.

         3. The internal balance room is equipped with a constant temperature water bath device to ensure the constant temperature of the balance room and greatly improve the stability of weighing.

         4. The instrument can do sample weight gain or weight loss experiments, such as the adsorption and decomposition process of samples;

         5. The closed ceramic insulation furnace structure greatly improves the signal sensitivity and resolution, and can obtain a more stable baseline;

         6. The furnace body is modular design, which is more flexible and more convenient to maintain.

         7. The furnace body is designed with a double-channel purge structure, which can better ensure the airtightness of the experimental process;

         8. The inside of the furnace is designed with a capillary water circulation refrigeration structure, which wraps the furnace body and is used for cooling the furnace body;

         9. The furnace body can reserve the experimental exhaust gas treatment interface according to customer needs, and the secondary analysis of experimental exhaust gas can be carried out;

        10. The sensor bracket is designed with imported materials, which is more resistant to corrosion, oxidation resistance, and high sensor sensitivity.

        11. The sampling frequency of the sensor signal can be set at 0.05~10Hz, which is more flexible and the data is more controllable.

        12. The design concept of dual temperature sensor can test the internal temperature of the furnace body and the sample temperature at the same time;

        13. The full temperature control system adopts the optimized dynamic PID algorithm, which greatly avoids the shortcomings of the traditional PID algorithm and improves the robustness of dual-mode temperature control.

        14. It has two experimental modes of FTC and STC, which can be set to control the temperature more friendly and flexible, which can meet the needs of different experiments in different application scenarios, control the temperature of the experimental process more accurately, analyze the sensor signal more efficiently, and accurately control the experimental effect;

        The 15th and 12th level of program temperature control settings make the experimental methods more diverse, and the equipment has a cyclic scanning function, the number of cyclic scans can be set up to 9999 times, and the data is automatically saved;

        16. The lower and upper computers of the equipment system have multi-point temperature correction functions at the same time, which meets the needs of different experimental occasions and improves the accuracy of temperature testing.

        17. The instrument is equipped with imported high-frequency core control processor, which has faster computing speed and more efficient control.

        18. Independent atmosphere control, through software intelligent settings, the instrument automatically switches the air circuit system, the experimental efficiency is higher;

        19. The equipment system can do experiments on heating, cooling and isothermal related materials;

        20. It adopts a 7-inch 24-bit full-color LCD touch screen to display the status and data of the instrument in real time.

        VS

        HuiCheng TGA-605S Thermal Gravimetric AnalyzerSpecifications

        LIST VALUE
        Temperature range Room Temperature~ 1550 ℃ (Platinum Rhodium Alloy Sensor)
        Temperature resolution 0.01℃
        temperature fluctuation ±0.01℃
        heating rate 0.1~100℃/min
        Balance Measurement range 0.01mg-5g
        mass resolution 0.01mg
        Thermostatic time 0~ 500Min (arbitrary setting)
        cool down 30min(1000℃…100℃)
        Timing Frequency 16.6Hz
        Sampling rate 0.05~ 10Hz Program settings
        experimental mode FTC, STC mode can be set arbitrarily
        Type of experiment Weight loss, weight gain (adsorption)
        programmed temperature control Flexible setting of 12-step temperature control in all stages
        Temperature control mode Heating, thermostatic, cooling
        number of cycles The number of cycles can be set up to 9999 times, and the data is automatically saved
        Instrument calibrated Lower computer and upper computer have multi-point temperature correction function at the same time
        Display mode 24Bit color 7 inch LCD Touchscreen display
        atmosphere control The atmosphere of the two channels can be set freely, and the instrument can be automatically switched
        parameter standard Equipped with standard materials, users can adjust the temperature by themselves
        power supply AC220V/50Hz (customizable AC110V)

        HuiCheng TGA-605S Thermal Gravimetric Analyzer Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        I want to test the thermal stability of plastic, what instrument is good?
        [A]
        Thermal Gravimetric Analyzer is recommended, which can directly analyze the thermal analysis process by observing the mass change of the sample by heating up. Your TGA-605S has high accuracy and dual gas circuit design, and the experimental results are more reliable.
        [Q]
        Do catalyst adsorption experiment, can use this instrument?
        [A]
        Yes, it can measure weight gain or weight loss experiments, such as adsorption and analysis; the TGA-605S has built-in Balance with temperature control compensation and can automatically switch the atmosphere, making it suitable for such applications.
        [Q]
        I need to measure the thermal stability and analysis temperature of plastics, what instrument is recommended?
        [A]
        TGA-605S Thermal Gravimetric Analyzer is recommended. It has built-in imported Balance, high accuracy, heating rate up to 100 ℃/min, can accurately capture the analysis process, and is very suitable for studying the thermal stability of plastics.
        HuiCheng
        Huicheng TGA-605S Thermal Gravimetric Analyzer Built-in imported Balance ceramic furnace body, dual temperature sensor Temperature range Room temperature to 1550 ℃
        Service
        Focus on online sales of Lab Testing Instruments