      Home> Ultrapure Water System> AIC> AIC ADW-4001-B Laboratory ultrapure water machine
      AIC ADW-4001-B  Laboratory ultrapure water machine

      AIC ADW-4001-B Laboratory Ultrapure Water System, Primary Reverse osmosis (RO)

      American AIC ADW-4001-B laboratory ultra-pure water machine, ultra-pure water machine suitable for basic physical and chemical experiments, first-level reverse osmosis (RO), with 40L/H pure water production, ultra-pure exchange capacity 5000L.

      Brand
      SKU: NB005198
      United States AIC
      VS
      AICLOGO

      AIC

      Information
      Genuinegoods
      • AIC ADW-4001-B Laboratory ultrapure water machineOverview

      • Specifications
      • Comments
      • FAQs
      ADW-4001-B
      Laboratory ultrapure water machine

      Features

      ØTap water enters, and water is produced automatically and continuously, which greatly meets the water needs of the laboratory;

      Ø Quickly reach 18.25MΩ stable water quality after startup, saving water, electricity and time;

      ØThe microcomputer chip fully automatically controls the operation of the equipment and meets GLP safety requirements;

      ØPower-on self-check, water shortage protection alarm, automatic reset after power outage, automatic shutdown when pure Water Tank is full, ultra-low Voltage protection, UV lamp failure alarm and other functions;

      ØUsing imported RO membrane, ion exchange resin, polished nuclear grade resin, silent high-pressure pump, solenoid valve, etc., product performance is maximized;

      ØRO automatically flushes and sterilizes regularly to maximize the service life of accessories;

      ØWater quality online monitoring system can instantly measure the quality of produced water.

      plan

      Appearance view of Ecopu ADW-4001-B laboratory Ultrapure Water System

      Scope of use

      Glass dish cleaning, potter, autoclave, heating pot, hydrogen generator, hydroponics, wind erosion resistance Tester, chemical oxygen demand, dissolution test, pH value measurement, surface tension experiment, aquarium.

      Features

      ØThe important parts are imported with original packaging, and the materials comply with the standards of NSF and Water Quality Association of the United States;

      ØStrictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;

      ØStandardized module design and production makes product maintenance more secure;

      ØThe "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.

      configuration list

      Serial numbernameModel specificationsquantityunitRemark
      1PP fiber filterSupporting1setAquapro
      2activated carbon filterSupporting1setAquapro
      3booster pumpSupporting1setAquapro
      4RO membrane moduleWater production: 40 L/h4setAquapro
      5pure Water Tank80L,PE1setAquapro
      6PumpSupporting1setAquapro
      7purification columnSupporting1setAquapro
      8Terminal ultrafiltration membraneSupporting1setAquapro
      9Product water quality resistance meterRCT-32001setROC
      10Control SystemSupporting1setAquapro


      VS

      AIC ADW-4001-B Laboratory ultrapure water machineSpecifications

      LIST VALUE
      Flow Rate 40L/h
      Flow velocity 1.0~1.5 L/min
      Pure water quality Conductivity: 2-10μs/cm25 ℃ (raw water TDS < 200ppm), in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard
      Ultrapure water quality Electrical resistivity 18.25MΩ .cm@25 ℃; particles (> 0.2um) < 1/ml
      Pure water storage bucket 80L
      Inlet source Municipal tap water, raw water conductivity < 1000μs/cm@25 ℃, total hardness < 200ppm, PH: 6.5-8, free chlorine < 1ppm
      inlet pressure 2-5Kg, water temperature 5-35 ℃
      Operating Environment Temperature 5~ 40 ℃, avoid direct sunlight
      Power 220V/50HZ, Power: 350W
      Host size 1080*560*500mm
      Application Glass dish cleaning, flooring device, autoclaving device, heating pot, hydrogen generator, hydroponics method, wind erosion Tester, chemical oxygen demand, dissolution test, pH value measurement, surface tension test, aquarium
      Application standard ISO9001:2008 Mass management system, NSF and Water Quality Association standards
      Produced water quality tertiary water

      AIC ADW-4001-B Laboratory ultrapure water machine Packing list

      host x1, manual x1, certificate x1, warranty contract x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the ultrapure water machine required in the GB/T1146.1 standard?
      [A]
      This ADW-4001-B ultra-pure water machine will do.
      AIC
      AIC ADW-4001-B Laboratory Ultrapure Water System, Primary Reverse osmosis (RO)
      Service