AIC AD2L-05-CE laboratory ultra-pure water machine, pure water output 5L/h
AIC AD2L-05-CE laboratory ultra-pure water machine, special pure water machine for physical and chemical experiments, water making speed is 5L/h, equipped with booster pump, AD2L-05-CE pure water heavy metals ions ≤ 0.1ppb.
AIC-
BIO0021 Puro80 Laboratory Water Purification System, three-stage water 80L/H water storage tank 60L
$ 8974.00 -
GUOHUA 1810-B quartz automatic double pure water distillation, water production speed: 2000~2500ml/h
$ 724.00 -
TIANMA UPTM-B60 Vertical ultrapure water mechanism Water volume 60L/H
$ 2378.00 -
BIO0021 Puro20 Laboratory Water Purification System, three-stage water 20L/h water storage tank 60L
$ 6074.00 -
MOLECULAR MU-20L laboratory ultra-pure water machine, water production rate 20L/h
$ 4346.00
Features
âInnovative and patented fully intelligent control system, fully automatic embedded microcomputer integrated control system (ARM9 high-end processor), true color TFT LCD touch screen, and graphical human-machine interface. The operation is simple, convenient and fast, bringing the user closer to the user. Like using a smartphone;
âOnline display of real-time operation data of water production and water intake of the whole system (raw water quality, temperature, ultrapure water quality, ultrapure water intake volume/water intake speed, dynamic display of Water Tank water volume and level). System data self-analysis and comparison, trend prediction, and preventive reminders to avoid experiments being interrupted without warning;
âUltrapure water can be taken quantitatively. The range of quantitative water taking is any integer volume, and the error is ±2ml (<500ml) or 1% (â¥500ml);
âAll monitoring data of the whole system are collected and recorded in real time, without the need for external computer storage, and the data within one year can be directly queried on the water machine;
âCloud service system. Data is collected and stored in real time. Users can directly export the data from the device through a USB flash drive, and upload it to the Aikopu cloud service center via the network every month for backup and diagnosis, and then trace it back to Aikopu professional engineers. Analyze the uploaded data and provide diagnostic reports and preventive maintenance recommendations to users based on the analysis results.
âPatented sterile water storage tank for easy cleaning and disinfection;
âABS casing, anti-corrosion, safety insulation performance meets GLP safety requirements.
Product display picture

Features
1. Important parts are imported with original packaging, and the materials comply with the standards of the American NSF and Water Quality Association;
2. Standardized module design and production makes product maintenance more secure;
3. The "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Application
Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blockade analysis, immunohistochemistry, histology, microbial culture media, nucleic acid electrophoresis, pyrogen-free water, toxicology research, etc. Experimental water.
AD2L-05-OR system configuration list
| Serial number | name | Model specifications | quantity | unit | Remark |
| 1 | PP fiber filter | Supporting | 1 | set | Aquapro |
| 2 | activated carbon filter | Supporting | 1 | set | Aquapro |
| 3 | booster pump | Supporting | 1 | set | Aquapro |
| 4 | RO membrane module | Water production: 10 L/h | 1 | set | Aquapro |
| 5 | Patented sterile pure water | 10L | 1 | set | AIC |
| storage device | |||||
| 6 | Pump | Supporting | 1 | set | Aquapro |
| 7 | purification column | Supporting | 1 | set | Aquapro |
| 8 | terminal filter | 0.22um | 1 | set | Sartorius |
| 9 | SMART-ANGEL | Supporting | 1 | set | AIC |
| Fully intelligent monitoring system | |||||
| 10 | touch system | Supporting | 1 | set | AIC |
| 11 | UV oxidation sterilization device | 185+254nm | 1 | set | Aquapro |
AD2L series parameter comparison
| model | AD2L-05-OR | AD2L-05-CE | AD2L-05-BE | AD2L-10-OR | AD2L-10-CE | AD2L-10-BE |
| application | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments |
| Pure water production | 5L/H | 10L/H | ||||
| Ultrapure water resistivity | 18.2MΩ.cm | |||||
| Pure water conductivity | 1-5us/cm | |||||
| Total organic carbon TOC | - | <10ppb | <5ppb | - | <10ppb | <5ppb |
| bacteria | - | <1CFU/ml | - | <1CFU/ml | ||
| Bacterial endotoxin | - | - | <0.001EU/ml | - | - | <0.001EU/ml |
| particulate matter | <1 piece/ml | |||||
| Inorganic ion removal rate | â¥99.5% | |||||
| heavy metal ion | â¤0.1ppb | |||||
| Silicon removal rate | ï¼99% | |||||
| Incoming water source | Municipal tap water, conductivity <1000 µS/cm@25℃, total hardness <200ppm, pH: 6.5-8.5, residual chlorine <1ppm, pressure: 0.2MPa-0.5MPa, temperature: 5-35℃. | |||||
| power supply | 220V/50Hz, 250W | |||||
| Dimensions | 395*535*580mm | |||||
| Application-BE | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blockade analysis, immunohistochemistry, histology, microbial culture media, nucleic acid electrophoresis, pyrogen-free water, toxicology research, etc. Experimental water. | |||||
| Application - CE | Histology, effective liquid chromatography, ultrahigh pressure liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, capillary electrophoresis, spectrophotometry, gas chromatography analysis, atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, NP analyzer, TOC Analysis, VOC analysis, Western blot method and other physical and chemical experiments and general biological experiments water. | |||||
| Application - OR | Glass dish cleaning, titrator, autoclave, biochemical oxygen demand, heating pot, hydrogen generator, hydroponics, Kedar analysis, stability test, wind erosion resistance Tester, chemical oxygen demand, dissolution test , gene chip analysis, particle analyzer, pH value measurement, surface tension experiment, animal water, aquarium and other basic physical and chemical experiment water. | |||||
AIC AD2L-05-CE Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | 5L/h |
| Flow velocity | 1.0~1.5 L/min |
| Pure water quality | Conductivity ≤ 5μs/cm@25 ℃, in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard |
| Ultrapure water quality | Electrical resistivity: 18.2MΩ .cm@25 ℃; particles (> 0.2um) < 1/ml; TOC * < 10ppb; microorganisms < 1cfu/ml |
| Inlet source | Municipal tap water, raw water conductivity: < 1000μs/cm@25 ℃, total hardness < 200ppm, PH: 6.5-8, free chlorine < 1ppm |
| inlet pressure | 1-5Kg, water temperature 5-35 ℃ |
| Operating Environment | Temperature 5~ 40 ℃, avoid direct sunlight |
| Power | 100-240VAC/50-60Hz, Power: 221W (max) |
| Host size | 580*395*535mm |
| Packing Weight | 36Kg |
| Application | Cell foster, non-nuclease applications, coalescence enzyme chain reaction, DNA sequencing, electrophysiology, endocrine blocking analysis, immunohistochemistry, histology, microbial foster groups, nucleic acid Electrophoresis, pyrogen-free water, toxicological research and other biological experimental water |
| Application standard | ISO9001:2008 Mass management system, NSF and Water Quality Association standards |
| Produced water quality | tertiary water |
AIC AD2L-05-CE Laboratory ultrapure water machine Packing list
host x1, manual x1, certificate x1, warranty contract x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- At low temperatures, several checks to be done before the ultra-pure water machine is used
- The correct operation method of ultra-pure water machine
- How long is the normal replacement cycle for the consumables of the experimental ultrapure water meter?
- It is definitely not wrong to buy a laboratory ultra-pure water machine like this.
- The other side of the Aikop ultrapure water machine, you know?
- What is the convenience of ultra-pure water machine water?
- How to choose the right ultra-pure water machine?
- Aquaplore Series Ultra Pure Water Machine User Manual
- Ultra-pure water machine better user experience
- How Aikopu Ultrapure Water Machine Can Provide Your Work Efficiency


AD2L-05-CE