AIC AD2L-10-CE laboratory ultra-pure water machine, pure water total organic carbon content < 10ppb
AIC AD2L-10-CE laboratory ultra-pure water machine, a special ultra-purified water machine for physical and chemical experiments, can produce three-grade water and ultra-pure water at the same time. The pure water output of AD2L-10-CE is 10L/h, and a patented sterile water storage tank is used for easy cleaning and disinfection.
AIC-
BIO0021 Puro20 Laboratory Water Purification System, three-stage water 20L/h water storage tank 60L
$ 6074.00 -
BIO0021 Geno20 Laboratory Water Purification System
$ 5463.00 -
LEICI UPW-N2-15UV Ultrapure Water System 15L/h
$ 2813.00 -
TIANMA UPTM-C100 Vertical Ultrapure Water Mechanism Water Quantity 100L/H
$ 5005.00 -
TIANMA UPTM-B60 Vertical ultrapure water mechanism Water volume 60L/H
$ 2378.00
Features
The innovative and patented fully intelligent control system adopts a fully automatic embedded microcomputer integrated control system (ARM9 high-end processor), a true-color TFT LCD touch screen, and a graphical human-machine interface. The operation is simple, convenient and fast, bringing the user closer to the user. Like using a smartphone;
Online display of real-time operation data of water production and water intake in the whole system (raw water quality, temperature, pressure, third-level water quality, third-level water intake volume/raw water flow rate, ultrapure water quality, ultrapure water intake volume/water intake rate, Water Tank water volume Liquid level dynamic display). System data self-analysis and comparison, trend prediction, and preventive reminders to avoid experiments being interrupted without warning;
The third-grade water/ultrapure water takes quantitative water respectively, and the quantitative water taking range is any integer volume, with an error of ±2ml (<500ml) or 1% (â¥500ml);
Two-stage reverse osmosis, patented special depth desalination treatment technology, ensures stable output of pure water quality â¤5 us/cm@25℃;
All monitoring data of the whole system are collected and recorded in real time, without the need for external computer storage, and the data within one year can be directly queried on the water machine;
Cloud service system. Data is collected and stored in real time. Users can directly export the data from the device through a USB flash drive, and upload it to the Aikopu cloud service center via the network every month for backup and diagnosis, and then retrospectively analyzed by Aikopu professional engineers. Upload data and provide diagnostic reports and preventive maintenance recommendations to users based on analysis results;
Patented sterile water storage tank for easy cleaning and disinfection;
ABS casing, anti-corrosion, safety insulation performance meets GLP safety requirements.
Product display picture

Features
1. Important parts are imported with original packaging, and the materials comply with the standards of the American NSF and Water Quality Association;
2. Standardized module design and production makes product maintenance more secure;
3. The "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Application
Histology, effective liquid chromatography, ultrahigh pressure liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, capillary electrophoresis, spectrophotometry, gas chromatography analysis, atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, NP analyzer, TOC Analysis, VOC analysis, Western blot method and other physical and chemical experiments and general biological experiments water.
AD2L-10-CE system configuration list
Serial number | name | Model specifications | quantity | unit | Remark |
1 | PP fiber filter | Supporting | 1 | set | Aquapro |
2 | activated carbon filter | Supporting | 1 | set | Aquapro |
3 | booster pump | Supporting | 1 | set | Aquapro |
4 | RO membrane module | Water production: 10 L/h | 1 | set | Aquapro |
5 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
6 | Pump | Supporting | 1 | set | Aquapro |
7 | purification column | Supporting | 1 | set | Aquapro |
8 | UV oxidation sterilization device | 185+254nm | 1 | set | Aquapro |
9 | terminal filter | 0.22um | 1 | set | Sartorius |
10 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
11 | touch system | Supporting | 1 | set | AIC |
AD2L series parameter comparison
| model | AD2L-05-OR | AD2L-05-CE | AD2L-05-BE | AD2L-10-OR | AD2L-10-CE | AD2L-10-BE |
| application | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments | Basic physical and chemical experiments | Physical and chemical experiments | Biological experiments |
| Pure water production | 5L/H | 10L/H | ||||
| Ultrapure water resistivity | 18.2MΩ.cm | |||||
| Pure water conductivity | 1-5us/cm | |||||
| Total organic carbon TOC | - | <10ppb | <5ppb | - | <10ppb | <5ppb |
| bacteria | - | <1CFU/ml | - | <1CFU/ml | ||
| Bacterial endotoxin | - | - | <0.001EU/ml | - | - | <0.001EU/ml |
| particulate matter | <1 piece/ml | |||||
| Inorganic ion removal rate | â¥99.5% | |||||
| heavy metal ion | â¤0.1ppb | |||||
| Silicon removal rate | ï¼99% | |||||
| Incoming water source | Municipal tap water, conductivity <1000 µS/cm@25℃, total hardness <200ppm, pH: 6.5-8.5, residual chlorine <1ppm, pressure: 0.2MPa-0.5MPa, temperature: 5-35℃. | |||||
| power supply | 220V/50Hz, 250W | |||||
| Dimensions | 395*535*580mm | |||||
| Application-BE | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blockade analysis, immunohistochemistry, histology, microbial culture media, nucleic acid electrophoresis, pyrogen-free water, toxicology research, etc. Experimental water. | |||||
| Application - CE | Histology, effective liquid chromatography, ultrahigh pressure liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, capillary electrophoresis, spectrophotometry, gas chromatography analysis, atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, NP analyzer, TOC Analysis, VOC analysis, Western blot method and other physical and chemical experiments and general biological experiments water. | |||||
| Application - OR | Glass dish cleaning, titrator, autoclave, biochemical oxygen demand, heating pot, hydrogen generator, hydroponics, Kedar analysis, stability test, wind erosion resistance Tester, chemical oxygen demand, dissolution test , gene chip analysis, particle analyzer, pH value measurement, surface tension experiment, animal water, aquarium and other basic physical and chemical experiment water. | |||||
AIC AD2L-10-CE Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | 10L/h |
| Flow velocity | 1.0~1.5 L/min |
| Pure water quality | Conductivity ≤ 5μs/cm@25 ℃, in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard |
| Ultrapure water quality | Electrical resistivity: 18.2MΩ .cm@25 ℃; TOC * < 10ppb; microorganisms < 1cfu/ml; particles (> 0.2um) < 1/ml |
| Pure water storage bucket | 10L |
| Inlet source | Municipal tap water, raw water conductivity: < 1000μs/cm@25 ℃, total hardness < 200ppm, PH: 6.5-8, free chlorine < 1ppm |
| inlet pressure | 1-5Kg, water temperature 5-35 ℃ |
| Operating Environment | Temperature 5~ 40 ℃, avoid direct sunlight |
| Power | 100-240VAC/50-60Hz, Power: 221W (max) |
| Host size | 580*395*535mm |
| Packing Weight | 36Kg |
| Application | Histology, effective liquid chromatograph, ultra-high Voltage liquid chromatograph, Mass Spectrometer, atomic emission spectroscopy (AES), protein Electrophoresis, capillary tubing Electrophoresis, spectrophotometric luminance, gas chromatograph analysis, atomic absorption spectroscopy (AAS), integrated circuits, chromatograph Mass spectrometry, NP analyzer, TOC analysis, VOC analysis, Western ink dot method and other physical and chemical experiments and ordinary biological experiments |
| Application standard | ISO9001:2008 Mass management system, NSF and Water Quality Association standards |
| Produced water quality | tertiary water |
AIC AD2L-10-CE Laboratory ultrapure water machine Packing list
host x1, manual x1, certificate x1, warranty contract x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ultrapure water system mass assurance
- It is definitely not wrong to buy a laboratory ultra-pure water machine like this.
- At low temperatures, several checks to be done before the ultra-pure water machine is used
- How long is the normal replacement cycle for the consumables of the experimental ultrapure water meter?
- How to reduce the operating cost of ultrapure water?
- How to choose the right ultra-pure water machine?
- The other side of the Aikop ultrapure water machine, you know?
- How does Aikop achieve high cost performance?
- How Aikopu Ultrapure Water Machine Can Provide Your Work Efficiency
- The correct operation method of ultra-pure water machine


AD2L-10-CE