AIC AD3L-05-08-CE intelligent ultra-pure water machine, ultra-pure water treatment capacity 8000L
AIC AD3L-05-08-CE intelligent ultra-pure water machine conforms to the standards of NSF and Water Quality Association of the United States, with a pure water production speed of 5L/H, suitable for tap water inlet sources, and suitable for various physical and chemical tests.
AIC-
BIO0021 Puro10 Laboratory Water Purification System, three-stage water 10L/H water storage tank 100L
$ 6137.00 -
MOLECULAR MU-20L laboratory ultra-pure water machine, water production rate 20L/h
$ 4346.00 -
BIO0021 Puro20 Laboratory Water Purification System, three-stage water 20L/hr water storage tank 30L
$ 5930.00 -
TIANMA UPTM-C80 Vertical Experiment Ultrapure Water Mechanism Water Quantity 80L/H
$ 4751.00 -
MOLECULAR MU-10L biochemical ultra-pure water machine, water production rate 10L/h
$ 3879.00
Features
âEquipped with complete purification unit:
a. Tap water pre-purification unit;
b. Two-stage reverse osmosis desalination pre-purification unit for tap water;
c. Sterile pure water storage unit (non-pressure barrel type);
d.Ultra-purification unit;
e. Post-processing unit;
f. Fully intelligent monitoring unit.
âFully intelligent control system, supports multi-language mode, multi-user use, and independent pricing. True color LCD touch screen, graphical human-machine interface, operation and information online query in one step. (Non-RS232 port external computer operation query)
âMulti-point full-line monitoring: source water quality/pressure/temperature/flow; pre-purification unit water flux accumulation; pre-purified water quality/water consumption; pure water storage capacity; ultrapure water quality/water consumption accumulation; UV life; Ultrafiltration water flux accumulation.
âThe setting of actual consumable operation confirmation data serves as a standard for online diagnosis to facilitate maintenance; reminders are displayed for consumable replacement. (Non-time set consumable reminder)
âAbnormal operation of the entire system (water quality and quantity of source water, pre-purified water, ultrapure water) online self-diagnosis, warning or automatic system stop operation, important system components (solenoid valve, booster pump, UV lamp, sensor, etc.) Intelligent fault judgment and online replacement instructions.
âTwo-stage reverse osmosis depth desalination, the raw water quality is less than 2000μs, the system salt removal rate is â¥99.5%, and the raw water utilization rate reaches 60-80%.
âTertiary water/ultrapure water are each quantitatively drawn. The quantitative water drawing range is any integer volume, and the error is ±2ml (<500ml) or 1% (â¥500ml).
âThe Zhencai display screen displays water quality, total water intake and flow rate online, allowing users to understand the water intake status at a glance.
âAll monitoring data of the entire system are collected in real time and can be viewed online without the need for external computer storage. The data storage capacity can reach more than one year.
âData is uploaded to the cloud service center via USB every month for backup and diagnosis. Professional engineers will retrospectively analyze the uploaded data and provide diagnostic reports and preventive maintenance recommendations to customers based on the analysis results.
âThe plug-and-play modular design of the system purification unit and components makes calibration, maintenance, cleaning, disinfection, and sampling during system validation easier.
Features
1. The whole machine is imported with original packaging and complies with the standards of NSF and Water Quality Association of the United States;
2. Strictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;
3. Standardized module design and production makes product maintenance more secure;
4. The "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Product display picture


Scope of application
Atomic absorption spectroscopy, histology, effective liquid chromatography, mass spectrometry, atomic emission spectroscopy, protein electrophoresis, ultrahigh pressure liquid chromatography, atomic absorption, capillary electrophoresis, clinical and biomedical laboratories, spectrophotometry, meteorological chromatographic analysis, atomic Absorption spectrum, integrated circuit, chromatography mass spectrometry, TOC analysis, VOC analysis, NP analyzer, CDC, drug testing institute, quality inspection institute, environmental supervision station, university scientific research, Western blotting method and other physical and chemical tests and general biological experiment water.
AD3L-05-08-CE system configuration list
serial number | name | Model specifications | quantity | unit | Remark |
1 | TAP-CLEAR module | Raw water treatment capacity: 20,000-30,000 L | 1 | Group | AIC |
2 | DP-RO module | Water production: 5 L/h | 1 | Group | AIC |
3 | ULTRA-CLEAR MODULE | Ultrapure water treatment capacity: 8,000 L | 1 | Group | AIC |
4 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
5 | UV oxidation sterilization device | 185+254nm | 1 | set | AIC |
6 | terminal filter | 0.22μm | 2 | set | Sartorius |
7 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
8 | touch system | Supporting | 1 | set | AIC |
AD3L series parameter comparison
| model | AD3L-05-03/08-BE | AD3L-08-03/08/16-BE | AD3L-16-03/08/16/24-BE | AD3L-05-03/08-CE | AD3L-08-03/08/16-CE | AD3L-16-03/08/16/24-CE | AD3L-05-03/08-OR | AD3L-08-03/08/16-OR | AD3L-16-03/08/16/24-OR | |||
| application | Ultrapure water machine for biological laboratories | Ultrapure water machine suitable for physical and chemical tests | Ultrapure water machine suitable for basic physical and chemical experiments | |||||||||
| Incoming water source | Municipal tap water inflow, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | |||||||||
| Pure water product* | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | |||
| Ultrapure water product* | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | |||
| Water flow rate* | 1-1.5 L/min | 1-1.5 L/min | 1-1.5 L/min | |||||||||
| Water production index | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | |||||||||
| Ultrapure water: resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <5ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml, bacterial endotoxin <0.001EU/ ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <10ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, particles (>0.2μm) <1/ml. | ||||||||||
| Application | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blocking analysis, immunohistochemistry, microbial culture media, pyrogen-free water, toxicology research and other biological experimental water. | Atomic absorption spectrometry, histology, effective liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, ultrahigh pressure liquid chromatography, atomic absorption, capillary electrophoresis, clinical and biomedical laboratories, spectrophotometry, meteorological chromatography analysis , atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, TOC analysis, VOC analysis, NP analyzer, CDC, drug testing institute, quality inspection institute, environmental supervision station, university scientific research, Western blotting method and other physical and chemical tests and general biological experiments Use water. | Glass dish cleaning, titrator, particle analyzer, animal water, water cluster box, autoclave, biochemical oxygen demand, dissolution test, gene chip analysis, heating pot, hydroponics, Kedar analysis, pH value Water for basic physical and chemical experiments such as measurement, stability test, surface tension experiment, and wind erosion resistance Tester. | |||||||||
| power supply | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | |||||||||
| Overall dimensions (mm) | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | |||||||||
AIC AD3L-05-08-CE Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | 5L/h |
| Flow velocity | 1.0~2.0 L/min |
| Ultrapurification Unit Capacity | 8000L |
| Pure water quality | Conductivity * ≤ 5μs/cm@25 ℃, in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard |
| Ultrapure water quality | Electrical resistivity: 18.2MΩ .cm@25 ℃; TOC ** < 5ppb; microorganisms < 1cfu/ml; particles (> 0.2um) < 1/ml |
| Pure water storage bucket | 10L |
| Inlet source | Municipal tap water, raw water conductivity: < 2000μs/cm, total hardness < 450ppm, PH: 6.5-8, free chlorine < 1ppm |
| inlet pressure | 1-5Kg, water temperature 5-35 ℃ |
| Operating Environment | Temperature 5~ 40 ℃, avoid direct sunlight |
| Power | 100-240VAC/50-60Hz, Power: 221W (max) |
| Host size | 550*420*550mm |
| Packing Weight | 51Kg |
| Interface | USB |
| Application standard | ISO9001:2008 Mass management system, NSF and Water Quality Association standards |
| Application | Atomic absorption spectroscopy (AAS), histology, effective liquid chromatograph, Mass Spectrometer, atomic emission spectroscopy (AES), protein Electrophoresis, ultra-high Voltage liquid chromatograph, atomic absorption, capillary tubing Electrophoresis, clinical and biomedical laboratories, spectrophotometric luminance, meteorological chromatograph analysis |
| Application | Atomic absorption spectroscopy (AAS), integrated circuits, chromatograph Mass spectrometry, TOC analysis, VOC analysis, NP analyzer, CDC, drug inspection, Quality control, environmental monitoring stations, university scientific research, Western ink dots and other physical and chemical tests and general biological experiment water |
| Produced water quality | tertiary water |
AIC AD3L-05-08-CE Laboratory ultrapure water machine Packing list
host x1, manual x1, certificate x1, warranty contract x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The correct operation method of ultra-pure water machine
- What factors will cause the service life and water quality of the ultra-pure water machine to decrease?
- Do you want to prepare a water storage tank for the laboratory ultra-pure water machine? Are there any hidden dangers?
- Component composition of ultrapure water equipment and functions of different components
- Aquaplore Series Ultra Pure Water Machine User Manual
- Ultra-pure water machine better user experience
- What are the advantages of the design of Aikop ultrapure water systems?
- How Aikopu Ultrapure Water Machine Can Provide Your Work Efficiency


AD3L-05-08-CE