AIC AD3L-08-08-BE laboratory ultra-pure water machine, pure water production speed 8L/h
AIC AD3L-08-08-BE laboratory ultra-pure water machine is suitable for biological laboratories, two-stage reverse osmosis (RO) deep desalination patent, tap water utilization rate is 60~80%, ultra-pure water production is 8T.
AIC-
BIO0021 Puro80 Laboratory Water Purification System, three-stage water 80L/H water storage tank 60L
$ 8974.00 -
TIANMA UPTM-B40 Vertical ultrapure water mechanism Water volume 40L/H
$ 2124.00 -
MOLECULAR MU-20L laboratory ultra-pure water machine, water production rate 20L/h
$ 4346.00 -
LEICI UPW-N30UV Ultrapure Water System
$ 2693.00 -
LEICI UPW-N2-15UV Ultrapure Water System 15L/h
$ 2813.00
Features
âThe whole machine is imported with original packaging and complies with the standards of American NSF and Water Quality Association;
âStrictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;
âStandardized module design and production ensures product maintenance and repair;
âThe "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Features
1) Equipped with a complete purification unit:
a. Tap water pre-purification unit;
b. Two-stage reverse osmosis desalination pre-purification unit for tap water;
c. Sterile pure water storage unit (non-pressure barrel type);
d.Ultra-purification unit;
e. Post-processing unit;
f. Fully intelligent monitoring unit.
2) Fully intelligent control system, supports multi-language mode, multi-user use, and independent pricing. True color LCD touch screen, graphical human-machine interface, operation and information online query in one step. (Non-RS232 port external computer operation query)
3) Multi-point full-line monitoring: source water quality/pressure/temperature/flow; pre-purification unit water flux accumulation; pre-purified water quality/water consumption; pure water storage capacity; ultrapure water quality/water consumption accumulation; UV life ;Ultrafiltration water flux accumulation.
4) The setting of actual consumable operation confirmation data serves as a standard for online diagnosis to facilitate maintenance; reminders are displayed for consumable replacement. (Non-time set consumable reminder)
5) Online self-diagnosis of abnormal operation of the entire system (water quality and quantity of source water, pre-purified water, ultrapure water), warning or automatic system shutdown, important system components (solenoid valves, booster pumps, UV lights, sensors, etc.) )Intelligent fault judgment and online replacement instructions.
6) Two-stage reverse osmosis depth desalination, the raw water quality is less than 2000μs, the system desalinization rate is â¥99.5%, and the raw water utilization rate reaches 60-80%.
7) Third-grade water/ultrapure water should be taken in a quantitative manner. The range of quantitative water taking is any integer volume, with an error of ±2ml (<500ml) or 1% (â¥500ml).
8) The Zhencai display screen displays water quality, total water intake and flow rate online, allowing users to understand the water intake status at a glance.
9) All monitoring data of the entire system are collected in real time and can be viewed online without the need for external computer storage. The data storage capacity can reach more than one year.
10) Data is uploaded to the cloud service center via USB every month for backup and diagnosis. Professional engineers will retrospectively analyze the uploaded data, and based on the analysis results, provide diagnostic reports and preventive maintenance recommendations to customers.
11) The plug-and-play modular design of the system purification unit and components makes calibration, maintenance, cleaning, disinfection, and sampling during system validation easier.
Product display picture


Scope of application
Atomic absorption spectrometry, cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, physiology, endocrine blockade analysis, immunohistochemistry, microbial culture media, northern and southern blot methods, nucleic acid electrophoresis, heat removal Raw water.
AD3L-08-08-BE system configuration list
serial number | name | Model specifications | quantity | unit | Remark |
1 | TAP-CLEAR module | Raw water treatment capacity: 20,000-30,000 L | 1 | Group | AIC |
2 | DP-RO module | Water production: 8 L/h | 1 | Group | AIC |
3 | ULTRA-CLEAR MODULE | Ultrapure water treatment capacity: 8000 L | 1 | Group | AIC |
4 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
5 | UV oxidation sterilization device | 185+254nm | 1 | set | AIC |
6 | Pyrogen removal ultrafiltration membrane | 6KD | 1 | set | AIC |
7 | terminal filter | 0.22μm | 2 | set | Sartorius |
8 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
9 | touch system | Supporting | 1 | set | AIC |
AIC AD3L-08-08-BE Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | 8L/h |
| Flow velocity | 1.0~2.0 L/min |
| Ultrapurification Unit Capacity | 8000L |
| Pure water quality | Conductivity * ≤ 5μs/cm@25 ℃, in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard |
| Ultrapure water quality | Electrical resistivity: 18.2MΩ .cm@25 ℃; TOC ** < 1-3ppb; microorganisms < 1cfu/ml; particles (> 0.2um) < 1/ml; bacterial endotoxin < 0.001EU/ml |
| Pure water storage bucket | 10L |
| Inlet source | Municipal tap water, raw water conductivity: < 2000μs/cm, total hardness < 450ppm, PH: 6.5-8, free chlorine < 1ppm |
| inlet pressure | 1-5Kg, water temperature 5-35 ℃ |
| Operating Environment | Temperature 5~ 40 ℃, avoid direct sunlight |
| Power | 100-240VAC/50-60Hz, Power: 221W (max) |
| Host size | 550*420*550mm |
| Packing Weight | 51Kg |
| Application | Atomic absorption spectroscopy (AAS) assays, cell foster, application of nuclease, coalescence chain reaction, DNA sequencing, physiology, endocrine blocking analysis, immunohistochemistry, microbial foster groups, northern and southern ink dots, nucleic acid Electrophoresis, pyrogen-removing water |
| Interface | USB |
| Application standard | ISO9001:2008 Mass management system, NSF and Water Quality Association standards |
| Produced water quality | tertiary water |
AIC AD3L-08-08-BE Laboratory ultrapure water machine Packing list
host x1, manual x1, certificate x1, warranty contract x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- One article explains the development process of ultra-pure water machine
- The correct operation method of ultra-pure water machine
- What factors will cause the service life and water quality of the ultra-pure water machine to decrease?
- Do you want to prepare a water storage tank for the laboratory ultra-pure water machine? Are there any hidden dangers?
- Component composition of ultrapure water equipment and functions of different components
- Introduction of various product series in Aikepu
- Complete solution to the advantages of Aikepu ultra-pure water machine products
- Aikepu helps users solve the confusion of selection
- The other side of the Aikop ultrapure water machine, you know?
- About the quantitative water intake function of Aikepu ultra-pure water machine


AD3L-08-08-BE