AIC AD3L-16-16-BE laboratory ultra-pure water machine, suitable for biological experiment water
AIC AD3L-16-16-BE laboratory ultra-pure water machine has an ultra-pure water treatment capacity of 16000L and a water intake Flow velocity of 1-1.5L/min. The microbial content of ultra-pure water produced by municipal tap water is less than 1cfu/ml.
AIC-
BIO0021 Puro10 Laboratory Water Purification System, three-stage water 10L/H water storage tank 60L
$ 5659.00 -
BIO0021 Puro20 Laboratory Water Purification System, three-stage water 20L/hr water storage tank 30L
$ 5930.00 -
TIANMA UPTM-B20 Experimental Benchtop Ultrapure Water Mechanism Water Quantity 20L/H
$ 1569.00 -
BIO0021 Geno50 Laboratory Water Purification System
$ 7534.00 -
MOLECULAR MU-05L laboratory ultra-pure water machine, water production rate 5L/h
$ 3413.00
Features
âEquipped with complete purification unit:
a. Tap water pre-purification unit;
b. Two-stage reverse osmosis desalination pre-purification unit for tap water;
c. Sterile pure water storage unit (non-pressure barrel type);
d.Ultra-purification unit;
e. Post-processing unit;
f. Fully intelligent monitoring unit.
âFully intelligent control system, supports multi-language mode, multi-user use, and independent pricing. True color LCD touch screen, graphical human-machine interface, operation and information online query in one step. (Non-RS232 port external computer operation query)
âMulti-point full-line monitoring: source water quality/pressure/temperature/flow; pre-purification unit water flux accumulation; pre-purified water quality/water consumption; pure water storage capacity; ultrapure water quality/water consumption accumulation; UV life; Ultrafiltration water flux accumulation.
âThe setting of actual consumable operation confirmation data serves as a standard for online diagnosis to facilitate maintenance; reminders are displayed for consumable replacement. (Non-time set consumable reminder)
âAbnormal operation of the entire system (water quality and quantity of source water, pre-purified water, ultrapure water) online self-diagnosis, warning or automatic system stop operation, important system components (solenoid valve, booster pump, UV lamp, sensor, etc.) Intelligent fault judgment and online replacement instructions.
âTwo-stage reverse osmosis depth desalination, the raw water quality is less than 2000μs, the system salt removal rate is â¥99.5%, and the raw water utilization rate reaches 60-80%.
âTertiary water/ultrapure water are each quantitatively drawn. The quantitative water drawing range is any integer volume, and the error is ±2ml (<500ml) or 1% (â¥500ml).
âThe Zhencai display screen displays water quality, total water intake and flow rate online, allowing users to understand the water intake status at a glance.
âAll monitoring data of the entire system are collected in real time and can be viewed online without the need for external computer storage. The data storage capacity can reach more than one year.
âData is uploaded to the cloud service center via USB every month for backup and diagnosis. Professional engineers will retrospectively analyze the uploaded data and provide diagnostic reports and preventive maintenance recommendations to customers based on the analysis results.
âThe plug-and-play modular design of the system purification unit and components makes calibration, maintenance, cleaning, disinfection, and sampling during system validation easier.
Product display picture


Features
1) The whole machine is imported with original packaging and complies with the standards of NSF and Water Quality Association of the United States;
2) Strictly implement the ISO9001:2008 quality management system to ensure uniform and stable product quality;
3) Standardized module design and production to ensure product maintenance and repair;
4) A "preventive maintenance" after-sales service system, combined with the Ecopu EMOAS network management platform, computerizes the historical operating status of the equipment to ensure long-term stable operation of the equipment.
Application
Atomic absorption spectrometry, cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, physiology, endocrine blockade analysis, immunohistochemistry, microbial culture media, northern and southern blot methods, nucleic acid electrophoresis, heat removal Raw water.
AD3L-16-16-BE system configuration list
serial number | name | Model specifications | quantity | unit | Remark |
1 | TAP-CLEAR module | Raw water treatment capacity: 20,000-30,000 L | 1 | Group | AIC |
2 | DP-RO module | Water production: 16 L/h | 1 | Group | AIC |
3 | ULTRA-CLEAR MODULE | Ultrapure water treatment capacity: 16000 L | 1 | Group | AIC |
4 | Patented sterile pure water storage device | 10L | 1 | set | AIC |
5 | UV oxidation sterilization device | 185+254nm | 1 | set | AIC |
6 | Pyrogen removal ultrafiltration membrane | 6KD | 1 | set | AIC |
7 | terminal filter | 0.22μm | 2 | set | Sartorius |
8 | SMART-ANGEL Fully intelligent monitoring system | Supporting | 1 | set | AIC |
9 | touch system | Supporting | 1 | set | AIC |
AD3L series parameter comparison
| model | AD3L-05-03/08-BE | AD3L-08-03/08/16-BE | AD3L-16-03/08/16/24-BE | AD3L-05-03/08-CE | AD3L-08-03/08/16-CE | AD3L-16-03/08/16/24-CE | AD3L-05-03/08-OR | AD3L-08-03/08/16-OR | AD3L-16-03/08/16/24-OR | |||
| application | Ultrapure water machine for biological laboratories | Ultrapure water machine suitable for physical and chemical tests | Ultrapure water machine suitable for basic physical and chemical experiments | |||||||||
| Incoming water source | Municipal tap water inflow, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | Incoming tap water, raw water hardness <450ppm, raw water conductivity <2000 u s/cm@25℃, raw water pressure: 1-5kg; water temperature: 5-35℃ | |||||||||
| Pure water product* | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | 5L/h | 8 L/h | 16 L/h | |||
| Ultrapure water product* | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | 3/8T | 3/8/16T | 3/8/16/24T | |||
| Water flow rate* | 1-1.5 L/min | 1-1.5 L/min | 1-1.5 L/min | |||||||||
| Water production index | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | Pure water: resistivity â¥0.2 MΩ.cm@25℃, Yougan CHINA laboratory water specification GB6682-2008 third-level water standard; | |||||||||
| Ultrapure water: resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <5ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml, bacterial endotoxin <0.001EU/ ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, TOC (processed by DP-RO) <10ppb, microorganisms <1cfu/ml, particles (>0.2μm) <1/ml. | Ultrapure water: Resistivity 18.25 MΩ.cm@25℃, particles (>0.2μm) <1/ml. | ||||||||||
| Application | Cell culture, nuclease-free applications, polymerase chain reaction, DNA sequencing, electrophysiology, endocrine blocking analysis, immunohistochemistry, microbial culture media, pyrogen-free water, toxicology research and other biological experimental water. | Atomic absorption spectrometry, histology, effective liquid chromatography, mass spectrometer, atomic emission spectrometry, protein electrophoresis, ultrahigh pressure liquid chromatography, atomic absorption, capillary electrophoresis, clinical and biomedical laboratories, spectrophotometry, meteorological chromatography analysis , atomic absorption spectrometry, integrated circuits, chromatography mass spectrometry, TOC analysis, VOC analysis, NP analyzer, CDC, drug testing institute, quality inspection institute, environmental supervision station, university scientific research, Western blotting method and other physical and chemical tests and general biological experiments Use water. | Glass dish cleaning, titrator, particle analyzer, animal water, water cluster box, autoclave, biochemical oxygen demand, dissolution test, gene chip analysis, heating pot, hydroponics, Kedar analysis, pH value Water for basic physical and chemical experiments such as measurement, stability test, surface tension experiment, and wind erosion resistance Tester. | |||||||||
| power supply | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | 100-240VA, 50-60Hz, 300VA | |||||||||
| Overall dimensions (mm) | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | HxWxDï¼650x450x550 | |||||||||
AIC AD3L-16-16-BE Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Flow Rate | 16L/h |
| Flow velocity | 1.0~2.0 L/min |
| Ultrapurification Unit Capacity | 16000L |
| Pure water quality | Conductivity * ≤ 5μs/cm@25 ℃, in line with the Chinese laboratory water specification GB/T6682-2008 tertiary water standard |
| Ultrapure water quality | Electrical resistivity: 18.2MΩ .cm@25 ℃; TOC ** < 1-3ppb; microorganisms < 1cfu/ml; particles (> 0.2um) < 1/ml; bacterial endotoxin < 0.001EU/ml |
| Pure water storage bucket | 10L |
| Inlet source | Municipal tap water, raw water conductivity: < 2000μs/cm, total hardness < 450ppm, PH: 6.5-8, free chlorine < 1ppm |
| inlet pressure | 1-5Kg, water temperature 5-35 ℃ |
| Operating Environment | Temperature 5~ 40 ℃, avoid direct sunlight |
| Power | 100-240VAC/50-60Hz, Power: 221W (max) |
| Host size | 550*420*550mm |
| Packing Weight | 51Kg |
| Application | Atomic absorption spectroscopy (AAS) assays, cell foster, application of nuclease, coalescence chain reaction, DNA sequencing, physiology, endocrine blocking analysis, immunohistochemistry, microbial foster groups, northern and southern ink dots, nucleic acid Electrophoresis, pyrogen-removing water |
| Interface | USB |
| Application standard | ISO9001:2008 Mass management system, NSF and Water Quality Association standards |
| Produced water quality | tertiary water |
AIC AD3L-16-16-BE Laboratory ultrapure water machine Packing list
host x1, manual x1, certificate x1, warranty contract x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The correct operation method of ultra-pure water machine
- What factors will cause the service life and water quality of the ultra-pure water machine to decrease?
- Do you want to prepare a water storage tank for the laboratory ultra-pure water machine? Are there any hidden dangers?
- Component composition of ultrapure water equipment and functions of different components
- What is the significance of the intelligence of laboratory small ultra-pure water machines?
- What convenience does the laboratory ultra-pure water machine bring to users by using two-stage reverse osmosis purification technology?
- A complete solution to the technical advantages of Aikepu ultrapure water system
- The other side of the Aikop ultrapure water machine, you know?
- How to choose the right ultra-pure water machine?
- Complete solution to the advantages of Aikepu ultra-pure water machine products


AD3L-16-16-BE