Linshang FNF2000-X1 Coating thickness gauge Probe 90 ° Right angle double base Probe
Double base Probe, magnetic Induction/eddy current induction, range 0~ 2000μm, resolution 0.1μm, accuracy +/- (2% H + 1μm) or +/- 3% H, minimum substrate thickness Fe0.2mm/NFe0.05mm, minimum radius of curvature convex surface 3mm, 90 ° right angle, suitable for Hole slot-die, plug-in, digital Probe technology, high Hardness probe.
LinShang-
LANDTEK CM8825Fn platings thickness measurement instrument, dual function Coating thickness measurement instrument
$ 406.00 -
Defelsko FS conventional strip probe 0~1500μm/non-ferrous metal
$ 728.00 -
Defelsko Positector 6000 FJS3 fireproof coating Thickness Gauge 25mm
$ 2140.00 -
German EPK probe N100 eddy current Thickness Gauge probe, thickness range 0~100000um
$ 4190.00 -
LANDTEK CM8825n Handheld Thickness Meter, Integrated Handheld Thickness Meter
$ 324.00
Product Introduction
The FNF2000-X1 is a dual-base probe capable of simultaneously measuring both magnetic and non-magnetic metal substrates. It is a 90° right-angle probe suitable for measuring coating thickness on holes and slits, and is an optional probe for the LS227 coating thickness gauge.

Meets the standards
GB/T 4956-2025 Measurement of Thickness of Non-magnetic Covering Layer on Magnetic Substrate—Magnetic Method
GB/T 4957-2025 Measurement of Non-conductive Coating Thickness on Non-Magnetic Matrix Metals - Amplitude-Sensitive Eddy Current Method
DIN EN ISO 2808 Determination of coating and varnish film thickness
JJG-818-2018 Verification Procedures for Magnetic and Eddy Current Cover Thickness Measuring Instruments
Product features
1. Plug-in probe design.
2. Utilizes advanced digital probe technology, with digital signal processing performed directly on the probe, making the probe less susceptible to interference and providing excellent testing accuracy.
3. High-hardness probe ensures long-term effective use of the instrument
Probe selection
| Probe model | Range | Features |
| F600-X0 | 0-600μm | Iron-based, straight probe, ultra-small probe, suitable for measuring the thickness of thin coated coatings on small workpieces |
| NF1600-X0 | 0-1600μm | Non-iron-based, straight probe, ultra-small probe, suitable for anodized layer measurement on small workpieces |
| FNF2000-X0 | 0-2000μm | Dual-base, straight probe, standard range, suitable for coating and paint thickness measurement |
| FNF5000-X0 | 0-5000μm | Dual-base, straight probe, large range, suitable for coating and paint thickness measurement |
| FNF20000-X0 | 10-20000μm | Dual-base, straight probe, ultra-wide range, suitable for measuring fireproof coatings and coating thickness |
| FNF2000-X1 | 0-2000μm | Dual-base, 90° right-angle probe, suitable for measuring coating thickness on holes and slits |
| F2000-X2 | 0-2000μm | Iron-based, 90° long rod probe, suitable for measuring coating thickness on pipe inner walls and fine grooves |
| NF2000-X2 | 0-2000μm | Non-iron-based, 90° long-rod probe, suitable for measuring coating thickness on pipe inner walls and fine grooves |
Actual test demonstration

LinShang FNF2000-X1 Coating thickness gauge (Coating Thickness Gauge)Specifications
| LIST | VALUE |
|---|---|
| Probe type | 90 ° right angle |
| Measurement principle | Magnetic Induction/Eddy Current Induction |
| matrix material | Ferromagnetic metal/non-ferromagnetic metal |
| Measurement range | 0.0~2000μm |
| resolution | 0.1μm:(0μm - 99.9μm),1μm:(100μm - 2000μm) |
| accuracy | H < 1000 μm : +/- ( 2% H + 1 μm), H ≥ 1000 μm: +/- 3% H (five point calibrated, H is the Standard value) |
| time interval | 0.8s |
| minimum matrix thickness | Fe:0.2mm / NFe:0.05mm |
| minimum radius of curvature | Convex 3mm |
| Probe weight | Approx. 80g |
LinShang FNF2000-X1 Coating thickness gauge (Coating Thickness Gauge) Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


FNF2000-X1
NF2000-X2
F2000-X2
FNF20000-X0
FNF5000-X0
FNF2000-X0
NF1600-X0
F600-X0