MODERNER QXD-25 small double-channel qxd Fineness gauge 25 micron particle Fineness gauge
Double-channel qxd Fineness meter, applicable to standard JJG (chemical) 018-96, GB/T1724, range 0~25μm, Graduation 2.5μm
Moderner-
JINGKELIAN QXD (0-100um Stainless Steel) Fineness of Ground Gauge 0~100μm/5μm
$ 133.00 -
JINGKELIAN QXP 0-50S ISO Fineness of Ground Gauge with Third Party Measurement Certificate
$ 245.00 -
Germany Erichsen 232 fineness gauge scraper 100μm Fineness gauge colorants/pigment fineness detection
$ 817.00 -
Pushen QXD-150um single-channe scraper Fineness gauge 0-150μm
$ 161.00 -
QXP0-100S double-channel Fineness Gauge YONGLIDA QXP Fineness Gauge
$ 192.00
Introduction of small double groove qxd Fineness Meter
MODERNER QXD stainless steel Fineness of Grind Gauge is a small double-slot type qxd Fineness Meter, which is made of high-grade stainless steel, and the applicable measuring range is 0~25/50/100 microns. The Fineness of Grind Gauge is widely used in the measurement of the fineness of particles such as pigments and impurities in paints and varnishes. MODERNER is a qxd Fineness Meter designed and manufactured according to the verification regulations of the Ministry of Chemical Industry of the People's Republic of CHINA JJG (chemical) 018-96 "Fineness of Grind Gauge" and its GB/T1724 standard .
The models of QXD-25/50/100 small double-slot qxd Fineness Meter are QXD-25, QXD-50, QXD-100, and the corresponding measuring ranges are 0~25 microns, 0~50 microns, 0~100 microns .
Steps for usage
1. Before using the qxd Fineness Meter , wash the plate and the bottom with a suitable solvent, and dry it with cotton yarn.
2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.
3. Drop a few drops of sample solution into the deepest part of the groove of the stainless steel Grindometer.
4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.
5. After scraping, immediately (within no more than 5 seconds) pinch the fineness gauge horizontally and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the scale of the particles in the groove and the exposed part with light value, the reading value is the fineness of the measured object.
Precautions for use
(1) Do not scratch the surface of the qxd fineness gauge and the scraper.
(2) Wash and apply vaseline to prevent rust after use.
(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted and then measured.
(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.
real shot




MODERNER Fineness of Grind Gauge series specification list

Series
| Specification | Range | Division value | Effective Groove Size | unit |
| small single slot | 0-15 | 0.75 | 12.7*140 | μm |
| 0-25 | 1.25 | 12.7*140 | Hegman/μm | |
| 0-50 | 2.5 | 12.7*140 | Hegman/μm | |
| 0-100 | 5 | 12.7*140 | Hegman/μm | |
| 0-150 | 5 | 12.7*140 | μm | |
| small double slot | 0-25 | 2.5 | 12.7*140 | Hegman/μm |
| 0-50 | 2.5 | 12.7*140 | Hegman/μm | |
| 0-100 | 5 | 12.7*140 | Hegman/μm | |
| 0-150 | 5 | 12.7*140 | μm | |
| wide slot | 0-25 | 1.25 | 25.4*127 | Hegman/μm |
| 0-50 | 2.5 | 25.4*127 | Hegman/μm | |
| 0-100 | 5 | 25.4*127 | Hegman/μm | |
| large wide groove | 0-25 | 2.5 | 50.8*127 | Hegman/μm |
| 0-50 | 5 | 50.8*127 | Hegman/μm | |
| 0-100 | 5 | 50.8*127 | Hegman/μm | |
| Big double slot | 0-25 | 2.5 | 25.4*165 | Hegman/μm/NPIRI |
| 0-50 | 5 | 25.4*165 | Hegman/μm/NPIRI | |
| 0-100 | 5 | 25.4*165 | Hegman/μm/NPIRI | |
| Special double slot | 0-50 | 2 | 25.4*165 | μm |
| 0-250 | 10 | 25.4*165 | μm |
Moderner QXD-25 (small double-channel) Small double-channel Fineness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Scraper type | double-channel |
| Number of grooves | 2 |
| range | 0 ~ 25µm |
| Scale unit | mm |
| Scraper material | stainless steel |
| Scraper size | 170*63.5*12.7mm |
| Scraper size | 70mm |
| Applicable standard | JJG(化)018-96、GB/T1724 |
| Graduation | 2.5µm |
| Groove size | 12.7mm |
Moderner QXD-25 (small double-channel) Small double-channel Fineness gauge Packing list
Scraper x1, scraper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- IncomingGB/T 17001.3-2025
- ActiveGB/T 17473.2-2008
- ActiveGB/T 17001.6-2022
- ActiveHG/T 5776-2020
- ActiveHG/T 5370-2018
- ActiveHG/T 5175-2017
- ActiveQB/T 2025-2013
- ActiveASTM D3794-2022
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB/T 13217.3-2008
- ReplacedQB/T 2025-1994
- ReplacedASTM D1210-1996


QXD-25 (small double-channel)