CHIJIU 524G thermostatic Magnetic Stirrer 4 station Stir capacity is 3000mlx4
Max. stirring Capacity 3L * 4, heating power 600W per station, Temperature range RT +~ 150 ℃, Timer Range 0~250min, motor torque 20mN · M, stirring speed 1500rpm.
ChiJiu-
CHIJIU SH23-2 thermostatic Magnetic Stirrer stepless speed regulation 10L/150 ℃
$ 285.00 -
BIO0021 MS 25L Magnetic Stirrer 25L 200~2200rpm
Login -
CHIJIU SH21-2 thermostatic Magnetic Stirrer Aluminum Alloy Housing 10L/150 ℃
$ 240.00 -
BIO0021 MS HP5M 5 Position Heating Magnetic Stirrer 5 × 400ml 120 ℃
Login -
BANTE MS400 heating Magnetic Stirrer 2L/1250rpm with timing + 400 ℃ heating
$ 249.00
Product Description
The 524G constant temperature magnetic stirrer sets the stirring speed, heating temperature, Timer Setting, etc., and maintains the drive of the brushless DC motor, the speed is stable, and each station is used independently. More accurate temperature control, better performance.
product display

Temperature Control Features
The 524G constant temperature magnetic stirrer adopts dual automatic temperature control of the Heating Plate temperature and the liquid temperature. Due to the large variables used by the user, such as the flatness of the bottom of the container, the size of the contact area with the Heating Plate, whether the container is glass or stainless steel, the amount of stirring, and the setting High-low temperature and so on. Both will affect the temperature control accuracy, so this machine is set with a temperature difference coefficient from 1 to 300, which can be set by the user. If you use a stainless steel tumbler, you can choose a smaller number, and if you use a glass beaker, you should choose a larger number. If the stirring volume is large and the setting temperature is high, select a larger number; if the stirring volume is small, the setting temperature is low, and select a small number. For example: 1000ml glass beaker (bottom is relatively flat), filled with 800ml silicone oil, the ambient temperature is 25°C, set The fixed temperature is 80°C, the temperature difference coefficient is selected as 99, and the control temperature can be stabilized at 79-80°C (the temperature displayed on the machine is measured at 80°C ± 0.5 with a thermometer)
Instructions
1. Place the stirrer stably, connect the power cord, connect the temperature sensor to the two terminal posts at the back of the machine, place the beaker containing the liquid medicine in the middle of the Heating Plate, and put a stirring bar, insert the temperature sensor into the liquid medicine, insert Connect the power plug, turn on the power switch (the power switch of the machine is behind the machine), the speed indicator light is on, and the number shows the original set speed;
2. Rotational speed setting: The four stations of this machine are operated independently, and the operation of one of the stations is taken as an example, and the rest are the same. Press the setting button once, the number will flash, use the up or down button to set the desired speed, when the speed is higher than 999, the decimal will light up, indicating that the displayed number × 10 times;
3. Time setting: press the setting button once, the time indicator light is on, use the up or down button to set the required time, if no timing is required, set the time to "0"
4. Temperature setting: Press the setting button once, the temperature indicator light will be on, and use the up or down button to set the required liquid temperature;
5. Temperature difference coefficient: press the setting button, the temperature difference indicator light is on, use the up or down button to set the required temperature difference coefficient, the first setting can be slightly smaller, if you find that the temperature rises too slowly or cannot reach the set temperature, you can reset it Set larger;
6. Press the setting button twice, the speed indicator light is on, showing the set speed, and the setting is completed;
7. Press the stirring button once, the stirring indicator light will be on, and the stirrer will run from slow to fast and reach the set speed;
8. Press the heating button once, the heating indicator light is on, heating starts, and the red temperature rise indicator light is on, indicating that the Heating Plate is powered on and heating;
9. The machine can only be heated when it is stirring. When the heating indicator is on, press the heating button again to stop heating. If you press the stirring button again, both stirring and heating will stop;
10. Display the current status: press the setting button, when the speed, time, temperature, and temperature difference indicators are on, it will display the current speed, remaining time, liquid temperature, etc. When the heating indicator light is off, the set temperature is displayed;
11. When the stirring is stopped, press the stirring key again, and the stirrer will run according to the data set last time;
12. When the machine is in the working state, press the up or down key to adjust the stirring speed. When the key is pressed, the digital display is the required speed for adjustment. After the key is released, the original display state will be restored. The adjusted stirring speed in the working state, The machine cannot be stored, and when it is turned on next time, it will work at the original stirring speed setting.
13. Except that the stirring speed of this machine can be adjusted under the working state, when other data needs to be newly set, the stirring key needs to be turned off first, and the data can be reset when pressing the setting key to an indicator light that needs to be reset;
14. When the agitator reaches the set time, there will be an alarm sound;
15. When the stirrer stops running, the power consumption is very small. If the time is short, it is not necessary to unplug the power supply.
Precautions
1. The power outlet should be well grounded;
2. When the machine is in use, the liquid medicine in the beaker should not be too full, so as not to overflow when stirring;
3. The temperature of the Heating Plate is very high when it is working, so the power cord and temperature sensor leads should be kept away from them, let alone touched;
4. If the machine is not used for a long time, it should be unplugged;
ChiJiu 524G Magnetic Stirrer (Multi-station)Specifications
| LIST | VALUE |
|---|---|
| Max. Capacity of stirring | 3L |
| Heating power per station | 600W |
| Temperature range | RT+~150°C |
| Dimensions | 380*380*145mm |
| Power | AV220V±10% 50Hz |
| Timer | 0~250min |
| Motor torque | 20mN·M |
| Stirring speed | 1500rpm |
ChiJiu 524G Magnetic Stirrer (Multi-station) Packing list
Host x1, Benchmark x2, Stir x8, temperature transducer x4, instruction manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Study on micromixing measurement in magnetic stirred reactor
- Application of Magnetic Stirrer in cathode coating process
- Magnetic Stirrer failure analysis and solutions
- Application of Magnetic Stirrer in Titration Operation
- What are the effects of object magnetism on the accuracy of Electronic Balance weighing?
- Comparative Analysis of Mechanical Drive and Magnetic Drive Stirs
- Talking about the use of magneticstirrer in rapid paraffin section
- Structural Design of Magnetic Drive Stir
- Graphic Design and Application of Ultra-thin Magnetic Stirrer
- Development process of graphic analysis magneticstirrer


524G