MOLECULAR MU-05L laboratory ultra-pure water machine, water production rate 5L/h
The MOLECULAR MU-05L laboratory ultra-pure water machine is an ultra-pure water machine with automatic intelligent control of microcomputer, which realizes 8-level pure water purification. The water production rate of MU-05L is 5L/h, and the water intake Flow velocity is 0.8L/min.
Molecular-
TIANMA UPTM-B20 Experimental Benchtop Ultrapure Water Mechanism Water Quantity 20L/H
$ 1569.00 -
TIANMA UPTM-C80 Vertical Experiment Ultrapure Water Mechanism Water Quantity 80L/H
$ 4751.00 -
TIANMA UPTM-C100 Vertical Ultrapure Water Mechanism Water Quantity 100L/H
$ 5005.00 -
TIANMA UPTM-A20 desktop ultra-pure water machine, water production 20L/H
$ 798.00 -
TIANMA UPTM-B80 Vertical ultrapure water mechanism Water volume 80L/H
$ 2731.00
Introduction
The water production rate of Moore MU-05L laboratory Ultrapure Water System is 5L/h, and the water intake rate is 0.8L/min. MU-05L laboratory Ultrapure Water System adopts fully automatic microcomputer intelligent control, touch buttons, and human-machine dialogue menu setting interface. In addition, it adopts large-scale integrated circuit and SMC patch assembly technology, color LCD display, and human-machine dialogue menu-style setting interface. Automatic display of machine status, full process monitoring equipment, consumable replacement prompts, multiple water intake modes of random, quantitative and qualitative, water use records, alarm records, current information query, automatic calendar and temperature display, optional connection with PC.
Equipment function configuration
This instrument is easy to operate and maintain, has low requirements on the laboratory environment, and is suitable for normal temperature and high humidity environments.
First-level purification: Use a 5μm coarse filter to remove particles, sand, suspended solids, algae, etc. in the water.
Second-level purification: Use high-quality coconut shell activated carbon to adsorb and remove residual chlorine, microorganisms, and colored and odorous substances in the water
The third level of purification: adopts precision filtration security device to improve the quality of reverse osmosis water and protect the reverse osmosis membrane.
The fourth level of purification: using high-quality original American Dow reverse osmosis membrane, the desalination and sterilization rate reaches more than 99%. Especially suitable for situations where tap water quality is poor.
Fifth-level purification: equipped with an integrated ultra-purification package Molup pack developed by Mol, with an ion removal rate of 99.999%.
The sixth level of purification: Rohm and Haas ultrapure polishing columns are used to effectively remove ions in the water, making the water quality reach ultrapure water.
The seventh level of purification: uses 254nm/185nm ultraviolet for cycle sterilization and removal of organic matter.
The eighth level of purification: uses 0.2μm German Sartorius tangential flow microfiltration membrane to intercept and remove bacteria.
Other instructions: 1. The pretreatment adopts a visible transparent cylinder to facilitate observation and replacement.
2. RO membrane intelligent anti-Graduation scheduled flushing and manual forced flushing.
3. Automatic internal circulation rinsing to maintain ultra-pure water quality.
4. Equipped with PE controllable pure Water Tank (including air filter).
5. Equipment used: DOW reverse osmosis membrane, Sartorius microfiltration membrane, Molup pack ultrapure column, ROHMHAAS polished ultrapure column, 185/254nm UV lamp, KEMFLO filter element and carbon filter. SMC solenoid valves, E-CHEN booster and delivery pumps, DMT pipe valves and fittings, magnetic resistors, Siemens electronic control components, liquid level controllers, and intelligent controllers.
Structure diagram


Product display picture

Pure water quality
The first type of water quality: GB Grade III pure water: used for cleaning experimental vessels and the most basic experiments.
The second type of ultrapure water quality:
1) Specific resistivity 18.25MΩ.cm@25℃; total organic carbon TOCâ¤1ppb
2) Absorbance (254nm, 1cm optical path): <0.001; microorganisms â¤1cfu/ml
3) Heat source <0.001EU/ml
4) Cation content (unit ppb): Fe<0.002, Cu<0.002, Al<0.003, Ni<0.001, Zn<0.005, Cr<0.001, Na<0.02, K<0.02
5) Anion content (unit ppb): Clâ<0.01, NO2â<0.02, NO3â<0.02, SO42â<0.01
Molecular MU-05L Laboratory ultrapure water machineSpecifications
| LIST | VALUE |
|---|---|
| Inlet source | Tap water, water pressure 0.1-0 MPa |
| Power | 220V/50HZ 150W |
| Flow Rate | 5L/h |
| Flow velocity | 0.8 L/min |
| Host size | 600*380*450mm |
| Pure water storage bucket | 25L |
| Operating Environment | The water temperature is 5~ 40 ℃, and the northern region needs an antifreeze room. |
| Application | High standard solution, buffer solution preparation, trace element quantitative analysis, atomic absorption, PCR, HPLC, liquid Mass spectrometry, emission Light spectrum, gas chromatograph, ion chromatograph, Electrophoresis, molecular biochemistry, cell fostering, microbial applications, immunology applications, protein purification analysis, TOC detection, DNA/RNA sequencing, etc |
Molecular MU-05L Laboratory ultrapure water machine Packing list
host x1, water tank x1, installation accessory package x1, manual x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Fault Analysis and Countermeasures of Laboratory Ultrapure Water Machine
- What experimental fields are laboratory ultrapure water machines used in?
- How does the ultra-pure water machine work?
- Molar reverse osmosis membrane performance parameters and cleaning and maintenance
- What affects the deterioration of the water quality of the ultra-pure water machine?
- Do you want to prepare a water storage tank for the laboratory ultra-pure water machine? Are there any hidden dangers?
- How to choose the laboratory ultra-pure water machine?
- What is the application of reverse osmosis membrane in ultra-pure water machine?
- MOLFOG10A Conditioning machine special pure water machine instruction manual
- Ultra-pure water machine from the clinical laboratory water standard
- IncomingGB/T 31531-2025
- ActiveGB/T 44184-2024
- ActiveJG/T 572-2019
- ActiveHG/T 3982-2007
- ActiveCJ/T 168-2002
- ActiveGB/T 41899-2022
- ActiveGB/T 33401-2016
- ActiveHG/T 5776-2020
- ActiveCY/T 205-2019
- ActiveGB/T 9779-2015
- ActiveGB/T 1740-2007
- ActiveGB/T 1733-1993
- ActiveHG/T 2471-2011
- GB 6682-2000
- ActiveJB/T 9857-2010
- ActiveGB/T 1733-1993


MU-05L





