      YUEPING NDJ-1S Rotational Viscometer Measurement range: (mPa · s) 10~100000 Error range: +/- 3%

      Digital display, Measurement range 10~100000mPa · s, Rotor specifications 1 #, 2 #, 3 #, 4 #, Rotor speed 6/12/30/60rpm, Measurement accuracy +/- 3% F. S, Interface PC interface

      Brand
      SKU: NB000585
      China YuePing
      Stock
      Loading…
      Price
      $ 453.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • YuePing NDJ-1S ViscometerOverview

        • Specifications
        • Comments
        • FAQs
        NDJ-1S
        Viscometer
        • YUEPING NDJ-1S Rotational Viscometer Measurement range: (mPa · s) 10~100000 Error range: +/- 3%
        • 越平NDJ-1S旋转粘度计形象图
        • 越平NDJ-1S旋转粘度计操作面板图
        Digital display, Measurement range 10~100000mPa · s, Rotor specifications 1 #, 2 #, 3 #, 4 #, Rotor speed 6/12/30/60rpm, Measurement accuracy +/- 3% F. S, Interface PC interface

        NDJ-1S Rotational Viscometer overview

        Yueping NDJ-1S Rotational Viscometer is a digital display Rotational Viscometer controlled by a 16-bit microcomputer. The measured data is displayed on the blue backlit display screen. There are "rotor selection", "confirmation" and "speed setting" on the operation panel. , "Start and stop" four buttons, equipped with 4 different standard rotors, which form different combinations with different speeds to measure liquids with different viscosity ranges, and have wide applicability. The measurable viscosity range of NDJ-1S Rotational Viscometer is 10-10 5 mPa·s .

        NDJ-1S rotary viscometer adopts 16-bit microcomputer processor as the core stepping electric high subdivision drive, LCD backlight display, with stable speed, good accuracy, programmed design, easy operation, error alarm and other functions, the screen directly Display information such as viscosity, rotational speed, percent torque, rotor number, and temperature of the measured liquid. The main control board and the subdivision driver board all adopt patch technology, and the circuit design adopts the current professional microcomputer processor, and the structure layout is reasonable and compact. NDJ-1S Rotational Viscometer full scale and linearity of each gear are all measured and corrected through the PC interface, and its measurement performance and functions have reached the professional level of the same type in CHINA.

        NDJ-1S digital viscometer features

        1. NDJ-1S Rotational Viscometer can provide the low viscosity option "No. 0 rotor" to accurately test the viscosity value in the range of 1~100mpa.s.

        2. With 16-bit microcomputer processor as the core, stepping electronics with high subdivision drive and LCD backlight display.

        3. The NDJ-1S rotary viscometer is controlled by a program-controlled motor, and the frequency change of the mains power does not affect the measurement accuracy.

        4. The whole machine is designed in one machine, which is easy to operate.

        5. The measurement data can be directly displayed on the LCD without secondary calculation.

        plan

        Appearance of Yueping NDJ-1S Rotational Viscometer

        Yueping NDJ-1S Rotational Viscometer packaging accessories diagram

        Yueping NDJ-1S Rotational Viscometer host front and rear view

        VS

        YuePing NDJ-1S ViscometerSpecifications

        LIST VALUE
        Display mode digital explicit
        Measurement range 10~100000mPa·s
        Rotor specification 1#、2#、3#、4#
        Rotor speed 6/12/30/60rpm
        Measurement Accuracy ±3%F.S
        Interface PC interface
        Dimensions 300*300*450mm

        YuePing NDJ-1S Viscometer Packing list

        Host x1, (No. 1, 2, 3, 4) rotor x1, bracket x1, manual x1, certificate x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Do you have the Viscometer involved in JJG1002?
        [A]
        The NDJ-1S Viscometer will do
        [Q]
        Should a small or large rotor be used for higher viscosity?
        [A]
        Hello, generally high viscosity liquids use small rotors, so that the speed is slow and the machine will not be damaged.
        [Q]
        How can this NDJ-1S rotational viscometer measure more accurate data?
        [A]
        Hello, you can pay attention to the following points during measurement: A, accurately control the temperature of the measured liquid; B, keep the environment temperature uniform; C, the rotor and the measured liquid must be constant temperature at the same time to keep the temperature consistent; D Low viscosity liquids generally use larger rotors, higher speed; high viscosity liquids, use smaller rotors, lower speed; E, keep the rotor surface clean.