JZ-650 High precision Colorimeter 4mm/8mm caliber, special measurement paste, powder, particles and other color difference
4mm/8mm dual diameter, built-in large-capacity lithium battery, ΔE * ab ≤ 0.06, with USB interface, flat, curved and small-area items can be measured.
Kingwell-
CHNSPEC CRX-51 Non-Contact Colorimeter
$ 11159.00 -
CHNSPEC CRX-50 Online Colorimeter, Non-Contact Colorimeter
$ 11626.00 -
IWAVE WR18 precision Colorimeter 4mm/8mm double color difference measurement caliber
$ 972.00 -
CHNSPEC CRX-52 Automotive Paint Online Colorimeter
$ 10693.00 -
3NH NH310 powder Colorimeter 8mm/4mm dual aperture, with multi-functional test components
$ 2294.00
Introduction
Kingwell JZ-650 high-precision Colorimeter is a multi-functional Colorimeter with dual measuring calibers. The measuring caliber is 4mm and 8mm. The appropriate measuring caliber can be selected according to the actual situation of the measurement. It can not only be used for general flat surfaces to be measured Object color measurement can also be used to measure small area and curved surface of the measured object. The JZ-650 high-precision Colorimeter uses a large-capacity lithium battery, which is energy-saving and environmentally friendly. The shape design conforms to ergonomics and uses high-quality sensors.
JZ-650 high-precision Colorimeter is a high-precision Colorimeter developed in accordance with CIE1931, 1974 and other international standards and relevant national standards. JZ-650 high-precision Colorimeter adopts German high-sensitivity sensors and light sources, and has a long service life. , cheap maintenance, stable performance and other characteristics, it is a powerful tool for the majority of color quality control, research and production personnel.
Pictures



Features
1) Professionally designed streamlined appearance, more in line with the requirements of human mechanics, JZ-650 high-precision Colorimeter is easy to operate
2) The JZ-650 high-precision Colorimeter has a selectable aperture measurement switch, which makes the data measured by different apertures more superior
3) Implement international common color standards, which can meet the communication of color data by customers in different industries
4) The newly designed small aperture design can not only measure narrower surfaces, but also measure curved surfaces, which solves the situation that the current domestic (CN) Colorimeter cannot measure special-shaped surfaces
5) Large-capacity 3200mAh lithium battery, which is safer and more convenient to use, and can meet the requirements of long-term measurement
6) JZ-650 high-precision Colorimeter adopts German high-sensitivity sensor and light source, and cooperates with more than 96% high-diffusion coating integrating sphere structure to make the measurement data more superior
7) Auxiliary accessories can also measure large-grained items, powder, and slurry objects
8) Standard computer software can realize more detailed color data exchange
Application
JZ-650 high-precision Colorimeter is suitable for: curved surface, paste, powder, textile, plastic, hardware, spraying, printing and other industries.

Kingwell 600 series high-precision Colorimeter comparison of parameters of all models
| Precision JZ-600 | Small aperture type JZ-610 | Large diameter type JZ-630 | Multifunctional JZ-650 | |
| optical geometry | 8/d, equipped with SCI and SCE simultaneous test mode | |||
| Measuring caliber | 8mm | 4mm | 14mm | MAV: 8mm SAV: 4mm |
| observer | 2° and 10° | |||
| sensor | Silicon photodiode array | |||
| system language | Simplified Chinese, Traditional Chinese, English | |||
| repeatability | Standard deviation △E﹡ab≤ 0.06 (White calibration plate measured 30 times after white calibration) | Standard deviation △E﹡ab≤ 0.06 (White calibration plate measured 30 times after white calibration) | Standard deviation △E﹡ab≤ 0.08 (White calibration plate measured 30 times after white calibration) | Standard deviation △E﹡ab≤ 0.06 (White calibration plate measured 30 times after white calibration) |
| show | Color difference value, chromaticity value, color space diagram, pass/fail judgment, color matching analysis | |||
| Observe the light source | D65 D50 C F11 | D65 D50 C F11 | D65 D50 C F11 | D65 D50 C A F2 F8 F11 |
| color space | L*a*b, L*c*h, Yxy, RGB | |||
| Color difference formula | △E*ab, △E*ch | △E*ab, △E*ch | △E*ab, △E*ch | △E*ab, △E*ch, CMC((1:1) CMC(2:1), yellowness Y1, whiteness W1 |
| power supply | Dedicated 3200mAh high-capacity lithium battery, AC adapter | |||
| Storing data | 20000 sets of data | |||
| size | 196×71×93 (length, width and height) | |||
| weight | 660g (including calibration plate) | |||
| interface | USB interface | |||
| Standard accessories | Black and white calibration board, USB cable, Φ8MM target mask, power adapter, lithium battery, color software | Black and white calibration board, USB cable, Φ4MM target mask, power adapter, lithium battery, color software | Black and white calibration board, USB cable, Φ14MM target mask, powder test tube, power adapter, lithium battery, color software | Black and white calibration board, USB cable, Φ8 and Φ4MM target mask, power adapter, lithium battery, color software |
| Optional | micro printer | |||
Kingwell JZ-650 High Precision ColorimeterSpecifications
| LIST | VALUE |
|---|---|
| Lighting method | 8°/d |
| Sensors | Silicon Photodiode Array |
| Measurement light source | D65,D50,C,A,F2,F8,F11 |
| Measurement caliber | MAV:8mm SAV:4mm |
| Sexual repeability | Standard deviation ΔE * ab ≤ 0.06 (30 measurements after whiteboard correction) |
| Operating language | Simplified Chinese, Traditional Chinese, English |
| Data Interface | USB interface |
| Viewing Angle | CIE 2 ° / 10 ° |
| Color difference formula | ΔE * ΔE * ch |
| Data storage | 20,000 sets of data |
| Power | Dedicated 3200mAh large-Capacity lithium battery, AC adapter |
| display mode | Color difference value, chromatic value, color space map, pass/fail judgment, color scheme analysis |
| Operating conditions | 0-40 ℃, Relative Humidity below 80%, no frost |
| Storage environment | 10-30 ℃, Relative Humidity below 70% |
| Dimensions | 196*71*93mm |
| Weight | 660G (including correction plate) |
| Chromaticity space | L*a*b、L*c*h、Yxy、RGB |
| Standard Accessories | Black and white correction board, USB cable, one each of Φ8 and Φ4MM target covers, power adapter, lithium battery, color software |
Kingwell JZ-650 High Precision Colorimeter Packing list
Host x1, black and white correction board x1, USB cable x1, Φ4MM target cover x1, Φ8MM target cover x1, power adapter x1, lithium battery x1, color software x1, manual x1, certificate warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Is there a Colorimeter suitable for pipes?
- Colorimeter measurement principle
- The Importance of Colorimeters in Color Detection
- Detection of color differences on wet or uneven surfaces
- Practical application of color reader
- Application of color difference meter in purple rice color difference detection and its measurement procedure
- Application of color difference meter in detection of advertising cloth coating color difference
- The measurement procedure of color difference meter in metal parts
- Color difference analyzer for vegetable color difference detection steps
- General steps of using color difference meter in color difference detection of thin film prints
- IncomingGB/T 36392-2025
- AbolishJB/T 5595-1991
- Active 0905-2015
- ActiveYS/T 680-2016
- ActiveGB/T 20147.3-2023
- ActiveGB/T 13448-2019
- ActiveISO 11664-3-2019
- ActiveGB/T 33421-2016
- ActiveGB/T 2374-2017
- ActiveGB/T 22374-2018
- ActiveGB/T 23997-2009
- ActiveGB/T 28197-2011
- ActiveHG/T 4767.3-2014
- ActiveHG/T 5183-2017
- ActiveGB/T 6688-2008
- ActiveGB/T 4739-2015
- ActiveGB/T 1766-2008
- ActiveGB/T 15608-2006
- ActiveGB/T 7707-2008
- ActiveGB/T 7975-2005


JZ-650
JZ-600
JZ-610
JZ-630