JINGKELIAN QUJ Thickness Gauge for paints dry-film thickness Measurement range 0-1000μm
Measurement range 0~1000μm, resolution 1μm, in line with GB/T1764-79, GB/T134522-92, ISO 2808-74 and other standards, widely used in the determination of paints dry-film thickness.
JingKeLian-
List Magnetik Pocket TOP-CHECK FE Pocket platings Thickness Gauge
$ 1177.00 -
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
$ 258.00 -
Defelsko FNTS thick coating probe 0~6mm/+/- 1%
$ 1328.00 -
German EPK MiniTest 600 B-F magnetic platings Thickness Gauge, thickness: 0~3000μm
$ 912.00 -
LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
Login
product description
The paint dry Film Thickness Gauge measures the dry film thickness by comparing before and after coating, and is widely used to determine the dry film thickness of paint coatings.
Paint dry Film Thickness Gauge technical parameters
Implementation standard: GB/T1764-79
ãããã GB/T134522-92
ãããã ISO2808-74
Measuring range: 0-1000μm
Dial indicator accuracy: 1μm
JingKeLian QUJ Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~1000μm |
| Resolution | 1μm |
| Standards | GB/T 1764-79、GB/T 134522-92、ISO 2808-74 |
JingKeLian QUJ Thickness Gauge Packing list
Thickness Gauge x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveQJ 990.3A-2011
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishISO 2808-2007
- AbolishGB/T 1764-1979
- ActiveGB/T 13452.2-2008


QUJ