Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Drying time Recorder> JingKeLian> JingKeLian QGZ-6 12 24 Drying Time Recorder
      JingKeLian QGZ-6 12 24 Drying Time Recorder

      JINGKELIAN QGZ-6 12 24 Film Drying Time Recorder Scribing radius: 0.25/0 5/1.0/1.5mm

      The number of strokes is 4, the size of the strokes is R 0.25/0 5/1.0/1.5mm, the stroke is φ 100mm, the track period is 6/12/24 h/T, the execution standard GB/T1728-79, and the measurement error is +/- 0.5%.

      Brand
      SKU: NB000630
      China JingKeLian
      Stock
      Loading…
      Price
      $ 212.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • JingKeLian QGZ-6 12 24 Drying Time RecorderOverview

        • Specifications
        • Comments
        • FAQs
        QGZ-6 12 24
        Drying Time Recorder
        • JINGKELIAN QGZ-6 12 24 Film Drying Time Recorder Scribing radius: 0.25/0 5/1.0/1.5mm
        The number of strokes is 4, the size of the strokes is R 0.25/0 5/1.0/1.5mm, the stroke is φ 100mm, the track period is 6/12/24 h/T, the execution standard GB/T1728-79, and the measurement error is +/- 0.5%.

        Application of paint film drying time Tester

        QGZ-(6, 12, 24) paint film drying time Tester is a new type of instrument for measuring paint drying time. For the coating film formed by various paints, it can automatically and continuously display the state of each stage of the drying process in the form of drawing a circular trajectory, and can intuitively analyze and observe the time spent in each stage. It is a satisfactory instrument for paint testing and paint formulation research.

        Structure of QGZ-6 12 24 paint film drying time Tester

        It consists of a switch (1), an outer cover (2), a motor (inside the cover), a foot (3), a connecting shaft (4), a rotating arm (5), a marking needle (6), a test plate (7), and a time dial (8) Composition.

        Structural diagram of QGZ-6 12 24 paint film drying time Tester

        Requirements for the use of automatic paint film drying time Tester

        1. Test plate: glass plate (200*200*2~3). Or smooth tin plate (200*200*0.2~0.3) or agreed test plate material.

        2. Test environment: According to the requirements of GB1727-79, the coated test panel is placed horizontally, away from airflow and direct sunlight, and the drying test is carried out at a temperature of 25±1°C and a Relative Humidity of 65±5%. Carry out the drying test according to other agreed conditions.

        Principle of Paint Film Drying Time Meter

        Place the paint film drying time Tester on the prepared coating film test plate, turn on the power supply, synchronize the motor, and drive the rotating arm (5) equipped with the scribing needle (6) through the connecting shaft (4). (The rotating arm is in a free-falling state) Rotate at a constant speed at a speed of one cycle/6 hours, one cycle/12 hours, one cycle/24 hours, and the scribing needle will draw a circular track with a diameter of 100mm on the coating film. As the coating film dries gradually over time, the plow mark on the coating film that the needle scratches changes from wide to narrow, from deep to shallow, until finally no trace can be drawn, thus showing the whole process of drying.


        VS

        JingKeLian QGZ-6 12 24 Drying Time RecorderSpecifications

        LIST VALUE
        Number of strokes 4 stitches
        Scratch Specifications R 0.25/0.5/1.0/1.5mm
        itinerary F100mm
        trajectory period 6/12/24h/T
        Execution standards GB/T1728-79
        Measurement error ±0.5%

        JingKeLian QGZ-6 12 24 Drying Time Recorder Packing list

        Drying time Recorder x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Help me find a film Drying time Recorder that meets the HG/T2003 standard
        [A]
        This QGZ-6 12 24 film Drying time Recorder is OK!
        [Q]
        How is the QGZ-6-12-24 drying performance tester used?
        [A]
        Hello, 1) Make a sample according to the requirements of GB1727; 2) Select the scribe needle according to the drying characteristics of the film (choose the fine scribe needle for quick-drying paint); 3) Use your finger to pull the rotating arm counterclockwise (looking down) to eliminate the mechanical gap, and then place the tester on the test board; 4) Make a mark on the contact part between the test board and the scribe needle, turn on the power supply, press the switch, the indicator light is on at the same time, the motor runs, and the test starts; 5) Make a mark on the contact part between the test board and the scribe needle, turn on the power supply, press the switch, the indicator light is on at the same time, the motor runs, and the test starts; 6) At the end of the test, turn off the power supply, remove the test board, and place the time dial concentrically on the test board, and align the 0 points on the The starting point of the test on the film surface is judged according to the different states of the film surface. The time used in each stage of the whole drying process can be judged.
        JingKeLian
        JINGKELIAN QGZ-6 12 24 Film Drying Time Recorder Scribing radius: 0.25/0 5/1.0/1.5mm
        Service
        Focus on online sales of Lab Testing Instruments