Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Tintometer> JingKeLian> JingKeLian QSG Iron Cobalt Tintometer

      JINGKELIAN QSG Iron and Cobalt Tintometer for the determination of varnishes, oils and thinners Color basis GB/T 1722-92

      Suitable for measuring varnish, oil and thinners Color. 18 different concentrations of solution composition 0~18 color scale label, execution standard GB/T1722-92.

      Brand
      SKU: NB000644
      China JingKeLian
      Model
      Stock
      Loading…
      Price
      $ 131.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • JingKeLian QSG Iron Cobalt TintometerOverview

        • Specifications
        • Comments
        • FAQs
        QSG
        Iron Cobalt Tintometer
        • JINGKELIAN QSG Iron and Cobalt Tintometer for the determination of varnishes, oils and thinners Color basis GB/T 1722-92
        • JINGKELIAN QSG Iron and Cobalt Tintometer for the determination of varnishes, oils and thinners Color basis GB/T 1722-92 Figure 1
        • JINGKELIAN QSG Iron and Cobalt Tintometer for the determination of varnishes, oils and thinners Color basis GB/T 1722-92 Figure 2
        Suitable for measuring varnish, oil and thinners Color. 18 different concentrations of solution composition 0~18 color scale label, execution standard GB/T1722-92.

        product description

        The OSG iron-cobalt Colorimeter is designed according to GB/T 1722-92 and is suitable for measuring the color of varnishes, varnishes and thinners. 18 kinds of solutions with different concentrations are composed of 0-18 color scale labels. In the standard light box, select the two samples whose color is closer to the 18 color scales, and express them with the color scale number that is confirmed to be the same as a certain color. Glass test tube: inner diameter Ø10.75±0.05mm, height 114±1mm.

        Specifications

        modelOSG
        Execution indicatorsGB/T1722-92
        standard color scale18 gears
        Color scale solutionPrepared according to GB/T1722-92

        Detail image

        Real shot of OSG iron-cobalt Colorimeter

        【tips】

                 According to the national standard of "Method for Determination of Color of Varnish, Varnish and Thinner", the color of varnish is measured with an iron-cobalt Colorimeter. The iron-cobalt Colorimeter is composed of iron trichloride, cobalt chloride and dilute hydrochloric acid solution according to the ratio specified in the standard, and is formulated into 18 color-level solutions with different depths (the iron-cobalt Colorimeter is divided into 18 color numbers, the higher the number The bigger the color is, the darker it is), which are divided into 18 test tubes, the tube mouths are sealed, and they are arranged on the rack in order, which is the iron-cobalt Colorimeter. When measuring, put the test sample paint into the test tube, compare it with the iron-cobalt Colorimeter under the dark box transmitted light, and take the most approximate solution color as the color of the sample, expressed by the color number. Such as: 
              C01-1 alkyd varnish No. 11, C01-7 alkyd varnish No. 12, etc.


        VS

        JingKeLian QSG Iron Cobalt TintometerSpecifications

        LIST VALUE
        Implementation indicators GB/T1722-92
        Standard Color Level 18th gear
        Color scale solution Prepared according to GB/T1722-92

        JingKeLian QSG Iron Cobalt Tintometer Packing list

        Tintometer x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is this a standard color? Because I have bought several sets, I don't know if it is a problem with different manufacturers, and I found that the Color is different.
        [A]
        We are all standard colors, and we will not say that there is the Color deviation you mentioned. Buy with confidence.
        [Q]
        Measuring the chroma of liquid raw materials, such as to distinguish different degrees of yellow
        [A]
        General Platinum Cobalt Colorimetry
        [Q]
        Is the Lightest Color Close to Colorless Transparency?
        [A]
        It's transparent.
        [Q]
        How long is the valid period of the QSG Iron Cobalt Tintometer? Will it be said that after a period of time, the Color will change?
        [A]
        Generally, the recommended verification time is 1-2 years. It is not a big problem to store it in a drying dark place for a long time.
        [Q]
        Does the QSG Iron Cobalt Tintometer comply with ASTM D1544? Can this also test Gardner chroma?
        [A]
        The standards are different. Ours is the national standard GB/T1722. It is different. This cannot be measured.
        JingKeLian
        JINGKELIAN QSG Iron and Cobalt Tintometer for the determination of varnishes, oils and thinners Color basis GB/T 1722-92
        Service
        Focus on online sales of Lab Testing Instruments