      Home> Thermostat> JIAHANG> JIAHANG JH-1000 Chill down water circulation device

      JIAHANG JH-1000 chilled down water circulator with a cooling capacity of 1000W

      JIAHANG JH-1000 chilled down water circulator, can be called thermostatic cold Water Tank, using imported Taikang compressor, cooling capacity is 1000W, is a PID temperature control chilled down water circulation equipment, JH-1000 comes with temperature overrun protection and automatic alarm function.

      Brand
      SKU: NB006559
      China JIAHANG
      Model
      VS
      Genuinegoods
      • JIAHANG JH-1000 Chill down water circulation deviceOverview

      • Specifications
      • Comments
      • FAQs
      JH-1000
      Chill down water circulation device

      Description

      Jiahang JH-1000 cooling water circulator adopts non-start-stop refrigeration technology, which is designed and manufactured to provide professional technical indicators and reliability in the industry, and is a high-precision and high-stability cooling equipment; The equipment adopts a fully enclosed refrigeration system, combined with PID temperature control, fast refrigeration, stable temperature, and meets some requirements for precision and constant temperature cooling equipment.

      Innovation advantage

      1) Adopt electronic expansion valve technology to control temperature, non-compressor start-stop type, reduce the damage to the compressor, and save 20% of electric energy;

      2) Automatic detection of high-low water levels, automatic prompting of liquid addition when low a certain value;

      3) The imported compressor has low sound and high refrigeration rate.

      Features

      1. The refrigeration system adopts imported Taikang compressor to ensure the refrigeration capacity and reduce the minimum noise at the same time.

      2PID temperature control technology is adopted. Refrigeration is not a traditional compressor start-stop type, and the use of electronic expansion valve technology greatly improves stability.

      3The refrigeration control system has its own temperature overrun protection and automatic alarm function, which fully prevents the damage of the constant temperature medium caused by low or high temperature value of the bath liquid.

      4With water level observation window and automatic water level detection device, the buzzer will automatically alarm if the water level is too low.

      5The automatic water flow detection device is convenient for automatic switching to internal circulation when the external circulation is blocked.

      6High-performance circulating water pump, which can maintain continuous work for a long time, good sealing and no leakage. The Circulating Chiller pressure is 0~1.5par, which can be adjusted by knob and displayed by pressure gauge. Enjoy a more intuitive operating experience.

      7. Color LCD screen display is used to display more data information and dynamic identifiers, so that you can see the running status of the instrument at a glance.

      Main application areas

      1. Analytical instruments: spectrometer, mass spectrometer, viscometer, polarimeter, fermentation device, rotary evaporator;

      2. **: Molecular pump, cryometer, X-ray machine, nuclear magnetic resonance, accelerator;

      3. Industrial equipment and others: laser equipment, vacuum coating equipment, biology, molds, machine tools, vacuum furnaces, welding machines, reactors.


      VS

      JIAHANG JH-1000 Chill down water circulation deviceSpecifications

      LIST VALUE
      Temperature range 5~40℃
      Temperature Fluctuation ±0.3℃
      Temperature Resolution 0.1℃
      Tank Volume 8L
      Temperature control mode Combining Hot Gas Bypass and PID
      Circular mode Internal/external circulation
      Total Power 1000W
      Timer 0~8h
      Power supply Voltage 220V 50Hz
      Flow rate of pump 20L/min

      JIAHANG JH-1000 Chill down water circulation device Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the low temperature limit of this JH-1000 chilled down water circulation unit?
      [A]
      JIAHANG JH-1000 meets the Temperature range of 5 to 40 ° C, with a minimum temperature of 5 ° C.
      [Q]
      Does the JIAHANG chilled down water circulation device meet the GB9278 standard?
      [A]
      The JH-1000 chilled down water circulation device can refer to
      +JIAHANG JH-1000 Chill down water circulation device Big data
        +JIAHANG JH-1000 Chill down water circulation deviceStandard
        +Navigation
        JIAHANG
        JIAHANG JH-1000 chilled down water circulator with a cooling capacity of 1000W
        Service
        Focus on online sales of Lab Testing Instruments