      Home> Reflectivity Meter> Moderner> Moderner C84-III reflectivity meter

      MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints

      Range 0-100; display accuracy 0.1, in line with ISO and GB standards;

      Brand
      SKU: NB000658
      China Moderner
      Model
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner C84-III reflectivity meterOverview

        • Specifications
        • Comments
        • FAQs
        C84-III
        reflectivity meter
        • MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints
        • MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints Figure 1
        • MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints Figure 2
        Range 0-100; display accuracy 0.1, in line with ISO and GB standards;

        Introduction

        MODERNER C84-III reflectance Tester is mainly used for the determination of the hiding power of white and light paints, and is also commonly used for the comparative test of coatings and paints. The C84-III reflectance Tester complies with international standards ISO 3905, ISO 3906, Chinese standards GB/T 13452, GB 9270, GB 5211.


        C84-III reflectance Tester actual picture .jpg

        Operating Principle

        The C84-III reflectance Tester consists of a probe, a main unit, a standard plate (one black and white), and two working ceramic plates.

        The probe adopts the principle of 0° irradiation and 45° reception. When the reflected light of the sample acts on the surface of the photocell, a telecommunication signal is generated and input to the DC amplifier for amplification, and the reading is displayed (see the optical path schematic diagram for details).

        The C84-III reflectance meter indicates a value that is proportional to the intensity of the light reflected from the surface being measured.

        Schematic diagram of the optical path .jpg


        Parameters

        Indication range: 0~100

        Display accuracy: 0.1

        Power supply: 220v 50Hz


        Live shot

        MODERNER C84-III reflectance Tester real picture 1

        MODERNER C84-III reflectance Tester real photo 2

        Figure 3 of the C84-III reflectance Tester in MODERNER

        MODERNER C84-III reflectance Tester accessories diagram

        Real view of the back of the C84-III reflectance Tester in MODERNER

        Detail of the MODERNER C84-III reflectometer probe

        Modern Environment C84-III Reflectance Tester Black and White Correction Plate


        How to use:

        1) Connect the probe to the electric control box and turn on the power supply. Place the probe on a black standard plate and turn on the machine to warm up for 3 minutes. When connecting, it should be noted that the groove on the plug should be aligned with the protrusion on the socket of the electric control box, and the plug should be pinched when unplugged, and the metal sliding sleeve of the plug should be pulled back, and then the plug should be unplugged, and the wire should never be pulled directly.

        2) Calibration: Put the probe on the black standard board, adjust the "zero" knob of the host, so that the number of the host is displayed as 00.0.

        3) Calibration standard value: Put the probe on the white standard plate and adjust the "full" knob of the host to make the value displayed by the host consistent with the calibration value of the white standard plate. The allowable variation ± 0.1. Repeat the adjustment once (zero, full).

        4) Measure the RB value: Move the probe to the black working ceramic plate where the specimen is placed, and the value displayed by the display is the RB value.

        5) Measure the Rw value: Move the probe to the white working ceramic plate where the sample is placed, and the value displayed by the display is the Rw value.

        6) Calculate and obtain the RB/Rw value of the coverage rate.

        Precautions

        1. In order to ensure the measurement accuracy, the measurement ambient temperature should be close to 25°C, and the C84-III reflectance Tester should be calibrated frequently. 

        2. In order to overcome the light fatigue of the photocell, the probe should be placed on the black standard plate during the test interval. Reduce the plug insertion and unplugging to avoid damaging the plug and causing poor contact.

        3. The white standard plate should be kept away from pollution, otherwise it will affect the measurement reading.

        4. If there is any stain on the white standard board, it can be removed with a high-grade drawing eraser.

        5. The preparation of samples should be carried out in accordance with the relevant national standards.

        Use, maintenance and troubleshooting

        1) Use and maintenance:

        The C84-III reflectance Tester adopts a highly sensitive photoelectric conversion device, which ensures that the illumination part and circuit part of the instrument are not affected by the external environment. Dust or moisture adsorbed on the translucent glass in the probe will affect the measurement reading, and should be wiped off with a lens cloth in time. The black and white standard board should be wiped clean before each use. If there are corrosive gases in the environment, the optoelectronic components in the instrument can be damaged.

        It is better if the probe can be stored in a drying tank when not in use.

         2) Troubleshooting:

        phenomenonFailure analysisdisposeThe digital meter is on and the LED is not

        phenomenonFailure analysisdispose
        The digital meter is on and the LED is not

        1. The probe lead is broken

        2. The LED is damaged

        Check the leads

        Replace the light-emitting diode

        The numerical display of the numerical table is unstable

        1. The emission of LEDs is unstable

        2. The Voltage regulator is unstable

        Replace the light-emitting diode

        Check the regulated power supply

        The reflectance Tester is a special instrument, and when the fault cannot be eliminated, it should be handed over to the instrument maintenance personnel or contact the instrument manufacturer, and it should not be dismantled and repaired at will.

         3) The C84-III reflectance Tester should be sent for inspection regularly to ensure the accuracy of use (1 time per year is recommended).

        VS

        Moderner C84-III reflectivity meterSpecifications

        LIST VALUE
        Indication interval 0~100
        Resolution 0.1
        Power Supply 220v 50Hz

        Moderner C84-III reflectivity meter Packing list

        Electrical box x1, probe x1, black standard board x1, white standard board x1, black work board (Pottery and porcelain) x2, white work board (Pottery and porcelain) x2, mirror cloth x1, advanced drawing eraser x1, polyester film x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        I want to measure the hiding power of White and Light Paints, which instrument should I choose?
        [A]
        The C84-III reflectivity meter is specially designed for the hiding power test of white and light Paints, which meets the international ISO 3905 and Chinese GB/T 13452 standards. It can accurately measure RB and Rw values to calculate the hiding ratio, which is very suitable for the quality control of the Coating industry.
        [Q]
        Where is this instrument mainly used in the coatings factory?
        [A]
        C84-III is often used for comparative testing and hiding power evaluation in Coating production, such as checking the uniformity and covering effect of Paints coatings, because it uses the principle of 0 ° irradiation 45 ° reception light path, which can stabilize the measurement of reflected light intensity and help ensure that the product meets industry standards.
        [Q]
        I want to test the reflectance of aluminum foil, how about C84-ⅲ?
        [A]
        C84 is to measure the inversion rate of Coating. The material to be tested is coated on the board for testing, and aluminum foil paper is not suitable.
        [Q]
        Is the C84-III reflectivity meter a C Light source?
        [A]
        D65 Light source
        [Q]
        Coating a white liquid onto a transparent PET film to dry, we need to test the hiding power of this white coating. Paper jams are too subjective. We need an instrument and equipment that can objectively test some values with this equipment. Is it necessary to calculate according to the calculation method on GB/T 13452.3-1992?
        [A]
        The test hiding power is calculated by the test reflectance, and the national standard is also the same. It does not directly show how much hiding power is. It is recommended that the reflectivity meter
        Moderner
        MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints