MODERNER LG-I 50-275 sagging Tester for determination of relative sagging of Paints
MODERNER LG-I 50-275 Sag Applicator has a film thickness range of 50~275 μm and a Graduation of 25 μm. It is mainly used to determine the relative sag of Paints and provide technical parameters for the on-site construction of Paints. This instrument conforms to GB9264 "Determination of Paints sag". This instrument is not suitable for testing the sag of varnishes and powder coatings.
Moderner-
MODERNER LG-1 Sag Tester Anti-Sag Meter 50-275μm
Login -
MODERNER LG-5 SAG Tester 850-1075μm Paints varnishes Anti-SAG Meter
Login -
TRUIT TR 3060/5 Anti-Sag Meter paints Sag Moulding Device
$ 141.00 -
PUSHEN LG 50-275 Sag Tester, groove depth 50-275 μm
$ 152.00 -
PUSHEN LG 450-1000 Sag Tester 450-1000 μm
$ 152.00
Main technical parameters of LG-I Sag Applicator
Model: LG-1
Specifications 50-275μm
Groove difference: 25μm
Product picture of LG-I Sag Applicator



Application of LG-I Sag Applicator
The Sag Applicator is mainly used to measure the relative sag properties of colored paints and provide technical parameters for on-site construction of colored paints. This instrument complies with GB9264 "Determination of Sag Properties of Paints". This instrument is not suitable for testing the sag properties of varnishes and powder coatings.
How to use LG-I Sag Applicator
(1) Prepare the test plate: Use a glass plate with a flat and smooth surface of 200mmÃ120mmÃ2~3mm.
(2) Place the test plate flat on the platform, being careful not to slide. Place the instrument on the top of the test plate, stir the sample thoroughly, place a sufficient amount of sample in the opening in front of the instrument, and hold both ends of the instrument with both hands. , move from front to back smoothly and continuously, completing this operation within 2-3 seconds.
(3) Immediately place the coated test panel vertically. When placing it, the strip film should be horizontal and keep "thin at the top and thick at the bottom".
(4) After the surface of the coating film is dry, observe its sagging. If the coating film of this thickness does not flow into the next thickness of film, it means that the coating film of this thickness does not sag.
Moderner LG-I 50-275 SAG TesterSpecifications
| LIST | VALUE |
|---|---|
| Film thickness range | 50~275μm |
| Graduation | 25μm |
Moderner LG-I 50-275 SAG Tester Packing list
SAG tester x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Active 052-2021
- ActiveASTM D4400-2018
- ActiveGB/T 9264-2012
- ActiveGB/T 9264-2012
- ActiveGB/T 9264-2012


LG-I 50-275