Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Anti-Sag Meter> Moderner> Moderner LG-I 50-275 SAG Tester

      MODERNER LG-I 50-275 sagging Tester for determination of relative sagging of Paints

      MODERNER LG-I 50-275 Sag Applicator has a film thickness range of 50~275 μm and a Graduation of 25 μm. It is mainly used to determine the relative sag of Paints and provide technical parameters for the on-site construction of Paints. This instrument conforms to GB9264 "Determination of Paints sag". This instrument is not suitable for testing the sag of varnishes and powder coatings.

      Brand
      SKU: NB000677
      China Moderner
      VS
      Genuinegoods
      • Moderner LG-I 50-275 SAG TesterOverview

      • Specifications
      • Comments
      • FAQs
      LG-I 50-275
      SAG Tester

      Main technical parameters of LG-I Sag Applicator

      Model: LG-1

      Specifications 50-275μm

      Groove difference: 25μm

      Product picture of LG-I Sag Applicator

      Picture 1 taken by LG-1 Sag Applicator

      Picture 2 taken by LG-1 Sag Applicator

      Picture 3 taken by LG-1 Sag Applicator

      Application of LG-I Sag Applicator

      The Sag Applicator is mainly used to measure the relative sag properties of colored paints and provide technical parameters for on-site construction of colored paints. This instrument complies with GB9264 "Determination of Sag Properties of Paints". This instrument is not suitable for testing the sag properties of varnishes and powder coatings.

      How to use LG-I Sag Applicator

      (1) Prepare the test plate: Use a glass plate with a flat and smooth surface of 200mm×120mm×2~3mm.

      (2) Place the test plate flat on the platform, being careful not to slide. Place the instrument on the top of the test plate, stir the sample thoroughly, place a sufficient amount of sample in the opening in front of the instrument, and hold both ends of the instrument with both hands. , move from front to back smoothly and continuously, completing this operation within 2-3 seconds.

      (3) Immediately place the coated test panel vertically. When placing it, the strip film should be horizontal and keep "thin at the top and thick at the bottom".

      (4) After the surface of the coating film is dry, observe its sagging. If the coating film of this thickness does not flow into the next thickness of film, it means that the coating film of this thickness does not sag.

      VS

      Moderner LG-I 50-275 SAG TesterSpecifications

      LIST VALUE
      Film thickness range 50~275μm
      Graduation 25μm

      Moderner LG-I 50-275 SAG Tester Packing list

      SAG tester x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the sag tester involved in GB/T9264?
      [A]
      The LG-I 50-275 sag tester will do
      [Q]
      Is this LG-I sag tester available for varnish sag determination?
      [A]
      Hello, not suitable, this LG-I 50-275 sag tester is not suitable for testing the sag of varnish and powder coatings.
      [Q]
      What is the difference between this sag tester and the Film Applicator?
      [A]
      Hello, the sag tester is used to test the anti-sag performance of Coatings, that is, to judge the maximum wet film thickness of a film formation; and the Film Applicator is used to Spreader the sample or sample of a specific wet film thickness.
      Moderner
      MODERNER LG-I 50-275 sagging Tester for determination of relative sagging of Paints
      Service