MODERNER LG250-475 Sag Applicator for determination of relative sag of Paints
The film thickness range of MODERNER LG250-475 Sag Applicator is 250~475μm, and the Graduation is 25μm. It is used to determine the relative sag of Paints and provide technical parameters for the on-site construction of Paints. This instrument conforms to GB9264 "Determination of Paints sag", and this instrument is not suitable for testing the sag of varnishes and powder coatings.
Moderner-
HuiNuo SAG 650-875 μm Coating Anti-Sag Meter Scraper, Laboratory Anti-Sag Meter
$ 167.00 -
QAG 50-275 Anti-Sag Meter YONGLIDA 50~275μm film thickness
$ 148.00 -
HUINUO SAG 50-275μm Coating sag, Laboratory Anti-Sag Meter
$ 167.00 -
TQC VF2250 sagging resistance Tester Anti-sagging Meter 50~275μm
$ 1544.00 -
MODERNER LG-5 SAG Tester 850-1075μm Paints varnishes Anti-SAG Meter
Login
Main technical parameters of LG-I Sag Applicator
Model: LG-2
Specifications 250-475μm
Groove difference: 25μm
Application of LG-I Sag Applicator
The Sag Applicator is mainly used to measure the relative sag properties of colored paints and provide technical parameters for on-site construction of colored paints. This instrument complies with GB9264 "Determination of Sag Properties of Paints". This instrument is not suitable for testing the sag properties of varnishes and powder coatings.
Product picture of LG-I Sag Applicator


How to use LG-I Sag Applicator
(1) Prepare the test plate: Use a glass plate with a flat and smooth surface of 200mmÃ120mmÃ2~3mm.
(2) Place the test plate flat on the platform, being careful not to slide. Place the instrument on the top of the test plate, stir the sample thoroughly, place a sufficient amount of sample in the opening in front of the instrument, and hold both ends of the instrument with both hands. , move from front to back smoothly and continuously, completing this operation within 2-3 seconds.
(3) Immediately place the coated test panel vertically. When placing it, the strip film should be horizontal and keep "thin at the top and thick at the bottom".
(4) After the surface of the coating film is dry, observe its sagging. If the coating film of this thickness does not flow into the next thickness of film, it means that the coating film of this thickness does not sag.
Moderner LG-I 250-475 SAG TesterSpecifications
| LIST | VALUE |
|---|---|
| Film thickness range | 250~475μm |
| Graduation | 25μm |
Moderner LG-I 250-475 SAG Tester Packing list
SAG tester x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Active 052-2021
- ActiveASTM D4400-2018
- ActiveGB/T 9264-2012
- ActiveGB/T 9264-2012
- ActiveGB/T 9264-2012


LG-I 250-475