      Home> GlossMeter> CQX> CQX CQ-60S Small hole Glossmeter

      CQX CQ-60S Small hole Glossmeter 60 °

      The CQX CQ-60S small hole Glossmeter is a 60-degree angle Gloss Detector. The CQ-60S small hole Glossmeter is suitable for surface Gloss testing of mechanical parts, jewelry, handicrafts, plastic pipes, Hardware and other products.

      Brand
      SKU: NB000696
      China CQX
      Model
      VS
      Information
      Genuinegoods
      • CQX CQ-60S Small hole GlossmeterOverview

      • Specifications
      • Comments
      • FAQs
      CQ-60S
      Small hole Glossmeter

      Introduction

      The CQ-60S small hole type gloss meter has an oval measuring window of 1.5x3mm and a small measuring aperture. It is a high-precision, compact and portable gloss meter. The small hole gloss meter is not only suitable for flat surface gloss measurement, but also widely used for gloss value measurement on coating surfaces with curved surfaces or special irregular shapes. The gloss meter is manufactured in compliance with ISO-2813 standards. It is suitable for measuring the surface glossiness of complex-shaped surfaces such as mechanical parts, jewelry, handicrafts, plastic pipes, hardware decoration, test samples, etc.

      Instructions

      Press the switch, place the small hole gloss meter on the black glass standard plate, and rotate the adjustment button to make the displayed value the same as the nominal value of the standard plate.

      Measurement skills

      1. When moving from a place with a lower temperature to a place with a higher temperature (such as outdoor to indoor in winter), please wait for a while before taking the measurement. (Because the optical lens changes from a place with low temperature to a place with high temperature

      The surface of the lens will become foggy)

      2. Please do not measure in an environment where the object under test is exposed to direct sunlight to avoid affecting the measurement value.

      3. When using a small hole gloss meter to measure a curved surface object, in order to ensure that the small hole is completely covered, the measuring hole of the gloss meter can be slowly covered with the measured object along the tangent line of the measured curved surface.

      Until the light spot on the measured object is no longer visible (the white light spot illuminated by the measuring hole on the measured object).

      Precautions

      1. Body:

      1) The gloss meter is an optical precision instrument and should avoid severe impact.

      2) Try to place it in a dry and clean environment.

      3) When the gloss meter is not suitable, please place the detection window downward to avoid contamination in the measurement chamber.

      4) After the measurement, be sure to turn off the power, put the small hole gloss meter into the instrument box and put it in a clean place for the next measurement.

      2. Accessories:

      1) Keep the standard plate of the small hole gloss meter clean to avoid measurement errors caused by inaccurate readings during instrument calibration.

      2) When the standard plate is stained, please wipe it with lens tissue or lens cleaning cloth. The black standard plate can be wiped with lens paper dipped in absolute ethanol.

      3. Calibration:

      1) When calibrating the small hole gloss meter, the single angle is placed in the inner frame of the standard plate box.

      VS

      CQX CQ-60S Small hole GlossmeterSpecifications

      LIST VALUE
      Measurement angle 60°
      Measurement range 0~199.9GU
      Error of indication <1.2GU
      Graduation 0.1GU
      Standards JJG first-class glossmeter standard, ISO-2813
      Operating language Chinese
      Dimensions 114*35*65mm
      Measurement port size 3*1.5mm
      Stability ±0.4GU
      Operating Voltage 3V
      Measurement port shape ellipse

      CQX CQ-60S Small hole Glossmeter Packing list

      host x1, standard blackboard x1, wiping cloth x1, manual x1, certificate x1, instrument case x1.

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the Geometry of CQ-60S Gloss meter?
      [A]
      Geometry is 60 degrees.
      [Q]
      How to measure the gloss of small curved tube with this small hole gloss instrument?
      [A]
      Hello, when using the CQ-60S small hole gloss instrument for measurement of curved objects, in order to ensure that the small holes are completely covered, the measurement hole of the gloss instrument can be slowly covered with the measured object along the tangent of the measured surface until the measured object cannot be seen. The light spot on the object (the white light spot irradiated by the measurement hole on the measured object) can be used.
      [Q]
      What solvent can be used to wipe the standard plate?
      [A]
      Hello, you can wipe it with lens paper dipped in absoluteethanol.
      [Q]
      Can the CQX CQ-60S small hole glossmeter meet the JJG696 standard?
      [A]
      Applicable, you can consult the customer service of the mall for details about the JJG696 standard.
      +CQX CQ-60S Small hole Glossmeter Big data
        +CQX CQ-60S Small hole GlossmeterSimilar products
        +CQX CQ-60S Small hole GlossmeterKnowledge
        +CQX CQ-60S Small hole GlossmeterStandard
        +Navigation
        CQX
        CQX CQ-60S Small hole Glossmeter 60 °
        Service
        Focus on online sales of Lab Testing Instruments