YouKe N5000 UV-Visible Spectrophotometer Single beam of light Light spectrum bandwidth 1.8nm
Single beam of light Optical inspection system, Wavelength range 190~1100nm, support U disk storage, standard 8G memory, automatic Light source adjustment and positioning, can be directly connected to the printer, support remote upgrade.
-
YueFeng 770S Ultraviolet-visible spectrophoto-meter full-band/sub-band scanning
$ 2496.00 -
JINGHUA 756 UV-Visible Spectrophotometer 2nm Light spectrum Bandwidth 190-1100nm Wavelength range
$ 1781.00 -
JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm
$ 2636.00 -
YueFeng 723S (PC) Visible Spectrophotometer 325nm~ 1100nm
$ 972.00 -
YueFeng 754 Ultraviolet-visible spectrophoto-meter 195~ 1000nm Bandwidth 4.0nm
$ 786.00
Features
1. 7-inch color display
The super-large screen displays various scanning curves and graphs, allowing users to complete all measurement needs without using a computer.
2. Support U disk storage, convenient for users to use
The data measured by the user can be directly exported to the U disk. The opening and editing of the data does not require any professional auxiliary software support. It can support excel, txt, and picture formats (four formats can be output: *.csv, *.qua, *tet, .bmp), which is convenient for users to edit experiment reports directly on the PC, which greatly saves the space of laboratory benches in colleges and universities, and is convenient for users to use.
3. Professional hardware in the industry
The industry uses a professional 32-bit Cortex_M3 processor, the main frequency reaches 120M, and the instrument can store 5000 test data or 500 working curves.
4. Rich expansion performance, greatly convenient for customers to use
Yoke N5000 UV-Vis Spectrophotometer is equipped with 8GB memory as standard, which can store test data in large quantities; the instrument is equipped with printing interface (232 ), HOSTUSB interface, and standard USB (A) interface.
4. Imported long-life socket deuterium lamp and tungsten lamp
2000-hour ultra-long life light source, the instrument automatically switches the light source according to the measurement needs, automatically records the use time of the light source, and the socket-type light source makes the replacement operation simple.
5. Optimized self-collimating optical path
1200 lines/mm effective planar holographic light, ultra-low stray light.
6. Super large sample room and various accessories are available to facilitate various measurement needs of users
7. It can be directly connected to a printer to output measurement maps and data
8. Powerful PC function software
9. The instrument can support remote upgrade, and support users to download the upgrade package from the official network
Features
●Large-capacity sample chamber design, various special accessories can be installed to meet the measurement requirements; 8 automatic disc rotary sample racks and 5 ultra-wide automatic sample racks are optional.
● The new optimized self-collimating CT optical path design ensures the measurement accuracy and stability of the instrument; the fully sealed optical path design effectively prolongs the service life of optical components and ensures the long-lasting stability of the instrument.
● High precision, integrated sine mechanism, reliable guarantee of Wavelength Accuracy.
● Automatic light source adjustment design, automatic positioning, to ensure that the optical system of the instrument is in good condition.
● Suspension optical system design, strengthen the design of thickened aluminum base plate, eliminate the impact of vibration or deformation on the optical system; the double-layer design completely separates the optical path and the circuit part, which facilitates the maintenance of the instrument and avoids the mutual flow of light and electricity , Improve the resolution and stability of the N5000 UV-Vis Spectrophotometer .
Application
N5000 UV-Vis Spectrophotometer can perform qualitative and quantitative analysis on sample substances in the ultraviolet and visible spectral regions, and can be widely used in medical and health, clinical testing, biochemistry, petrochemical, environmental testing, food hygiene and quality control and other departments , and can be used as a teaching demonstration and experimental instrument for related courses in colleges and universities.
plan

Yoke N5000 SpectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Optical inspection system | Single beam of light (1200/mm holographic light) |
| Light spectrum bandwidth | 1.8nm |
| Wavelength range | 190~1100nm |
| Wavelength Accuracy | ±0.3nm |
| Wavelength Repeatability | 0.1nm |
| Photometric range | 0~200%T、-0.3~3.0A、0~9999C(0~9999F) |
| Photometric Accuracy | ±0.3%T |
| stray light | ≤0.03%T@220nm,360nm |
| Baseline flatness | ±0.001nm |
| Interface | RS-232C serial port (printing), USB drive (Connectivity), USB HOST (connected to U disk) |
| display | 7-Inch color graphic LCD display with resolution 800x480 |
| Dimensions | 600*430*240mm |
| Weight | About 16kg |
| storage | 8GB memory as standard |
| processor | Cortex_M3 frequency 120MHz |
Yoke N5000 Spectrophotometer Packing list
Complete machine X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Calibration of Spectrophotometer s
- Spectrophotometric testing
- Did you know that the maturity of fruits and vegetables can be quantified?
- Why is testing of children's clothing and accessories important?
- Color Measurement Challenges Faced by Manufacturers in the Metals Industry
- Which Spectrophotometer is widely used in the metal industry?
- Liquid color difference detection solution
- How to detect the color difference of fluorescent color-changing materials?
- Detection of nicotine content by Spectrophotometer
- Differences between visible, ultraviolet-visible, infrared, fluorescent and atomic absorption Spectrophotometer s
- ActiveJJF 1641-2017
- ActiveJG/T 235-2014
- ActiveJY/T 0570-2020
- ActiveGB/T 15503-1995
- AbolishGB/T 10656-2008
- ActiveGB/T 34323-2017
- ActiveGB/T 26798-2011
- ActiveGB/T 11220.1-1989
- AbolishHJ/T 201-2005
- ActiveGB/T 27594-2011
- AbolishGB/T 1628.2-2000
- ActiveGB/T 1721-2008
- ActiveJB/T 6778-1993
- ActiveJB/T 6777-1993
- ActiveGB/T 26810-2011
- ActiveGB/T 26798-2011
- AbolishGB/T 11175-2002
- ISO 6271-2-2004
- ISO 4630-2-2004
- ISO 3856-5-1984


Yoke
N5000