Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Halogen Moisture Meter> Yoke> Yoke DSH-10A Halogen moisture meter

      YOKE DSH-10A Halogen moisture meter weighing value up to 10g accuracy 10mg

      The new product of SH-10A adopts high-precision thermal insulation Sensors, halogen lamp heating drying, LCD screen, built-in RS232C input interface.

      Brand
      SKU: NB007252
      China Yoke
      Model
      VS
      Genuinegoods
      • Yoke DSH-10A Halogen moisture meterOverview

      • Specifications
      • Comments
      • FAQs
      DSH-10A
      Halogen moisture meter
      • YOKE DSH-10A Halogen moisture meter weighing value up to 10g accuracy 10mg
      • YOKE DSH-10A Halogen moisture meter weighing value up to 10g accuracy 10mg Figure 1
      The new product of SH-10A adopts high-precision thermal insulation Sensors, halogen lamp heating drying, LCD screen, built-in RS232C input interface.

      Features

      1. The large high-resolution backlit dot-matrix LCD is easy to operate in the dark, and the vision is more comfortable.

      2. The key-type chain plate makes the operation more convenient.

      3. High-precision heat-insulated sensor, the collected data temperature is reliable.

      4. It adopts halogen lamp to heat and dry, so the temperature rises rapidly and the test time is short.

      Features

      1. During the test, the drying state can be directly confirmed and the end time can be estimated.

      2. Due to the automatic tare function, it can be measured continuously in real time, and can also be accurately measured through zero drift correction

      3. Built-in R232C output interface, which can be connected to peripheral devices such as computers and printers.

      Applications

      The Halogen Moisture Analyzer is used to quickly determine the free moisture of various samples such as chemical raw materials, grains, minerals, biological products, food, pharmaceutical raw materials, paper, and textile raw materials.

      plan

      Yoke DSH-10A Halogen Moisture Meter Display

      Models

      modelMaximum weighing valuereadabilityrepeatability
      DSH-10A10g10mg0.50%
      DSH-50A-150g1mg0.20%
      DSH-50A-550g5mg0.30%
      DSH-50A-1050g10mg0.50%
      Other parameters
      Minimum sample size0.5g
      Recommended sample size3 – 10g
      heating time1- 99 minutes in intervals of 10 seconds
      heating programstandard
      Operating temperature range10-30℃
      communicationSerial RS232
      End point controltiming, automatic
      Heating temperature range50°C to 160°C (1°C interval)
      Display contentSolid %, Moisture %, Weight, Time, Temperature
      Pan size100mm
      Dimensions285mm*160mm*150mm
      net weight3.0kg
      gross weight4.2kg
      heating sourceHalogen lamp


      VS

      Yoke DSH-10A Halogen moisture meterSpecifications

      LIST VALUE
      Maximum weighing value 10g
      Weighing readability 10mg
      Sexual repeability 0.5%
      Minimum sample size 0.5g
      Recommended sample size 3-10g
      Timer 1~99min
      Heating method standard
      Communication interface RS232
      How to end the measurement Timing, automatic
      Heating temperature range 50~180℃
      Display content Moisture%, solids%, Weight, time, date, etc
      Pan size F100mm
      Dimensions 265*160*150mm
      Net Weight 5kg
      Total Weight 6kg
      heating source Halogen lamp

      Yoke DSH-10A Halogen moisture meter Packing list

      host X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      How many degrees Celsius is suitable for heating this kind of Halogen moisture meter?
      [A]
      Selecting a suitable heating temperature requires neither analysis nor change the chemical structure of the sample, generally set to 105 ° C, unless the sample and industry have special requirements.
      [Q]
      Does the DSH moisture meter need to be weight calibrated?
      [A]
      Moisture meters use relative weight to measure results, so small deviations from absolute weight have little effect on measurement accuracy. Moisture meters have stable weighing performance and are less affected by temperature, and can maintain calibrated results for a long time, so weight calibrating is not required.
      [Q]
      What is the heating range of the DSH-10A halogen moisture tester?
      [A]
      Hello, the heating range of this DSH-10A halogen moisture tester is 50~ 180 ° C.
      [Q]
      Does this moisture tester come with peeling function?
      [A]
      Hello, DSH-10A halogen moisture tester, this one has a peeling function.
      [Q]
      Does this Halogen moisture meter comply with GB/T13025.3 standard?
      [A]
      The Halogen moisture meter is suitable for GB/T13025.3, please consult customer service for detailed application definition
      Yoke
      YOKE DSH-10A Halogen moisture meter weighing value up to 10g accuracy 10mg
      Service
      Focus on online sales of Lab Testing Instruments