Online ph acidity meter AOLILONG PHG-2 industrial acidity meter
PH Measurement range -4.00~18.00pH, PH Measurement accuracy +/- 0.01pH, resolution 0.01pH/1mV, Temperature Measurement range 0~99 ℃ (pH), Stability (zero drift) ≤ 0.02pH/24h; ≤ 3mV/24h
AOLILONG-
KEDIDA CT-6023 Pen type acidity meter with built-in electrode PH Range: 0.00~14.00PH
$ 114.00 -
AOLILONG PHB-10 pen pH meter laboratory test site, water quality assurance, industrial and mining production process and other ph value monitoring
$ 110.00 -
FANGZHOU FZ-831 Strong acid PH electrode can measure ≤ 1wt% concentration of hydrofluoric acid solution
$ 254.00 -
Glass electrode for PH-220 pen pH meter
$ 100.00 -
BANTE PHS-3CW-CN Laboratory pH Meter 0.00~14.00pH
$ 257.00
Introduction to PHG-2 Industrial Acidity Meter
The PHG-2 online pH acidity meter is a dedicated acidity meter for the industrial field. It has built-in imported high-quality chips and components, which ensures that the PHG -2 industrial acidity meter has good stability and reliable measurement data during long-term testing. Its resolution is 0.01pH. The PHG-2 industrial acidity meter has dual functions of PH/ORP and can be freely converted to meet the needs of different users. Its automatic correction and temperature compensation functions greatly reduce operating procedures.
PHG-2 online pH acidity meter is suitable for acidity detection in industrial sewage pools. It is Orilon's main industrial acidity meter product.
Features and advantages
1. PHG-2 industrial acidity meter has built-in imported chips and components to ensure long-term stable and reliable operation of the instrument;
2. The photoelectric coupler isolates and protects the 4~20mA signal output, and the input signal and the output signal are independent of each other;
3. EEPROM type memory, no backup battery required, data will not be lost after power outage;
4. High-performance operational amplifier, ORP positive and negative values ââare symmetrical, small temperature drift, stable and accurate;
5. Key sound prompt;
6. PHG-2 online pH meter has dual functions of pH/ORP, and the two functions can be easily converted to each other;
7. It has alarm display and control signal output functions;
8. With automatic correction and temperature compensation functions;
9. PHG-2 online pH meter has antimony electrode mode;
10. Suitable for indoor and panel installation.

AOLILONG PHG-2 Industrial online pH MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -4.00~18.00pH |
| PH measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH/1mV |
| Temperature Measurement Range | 0~99℃(pH) |
| Stability (zero drift) | ≤0.02pH/24h;≤3mV/24h |
| Dimensions | 96*96mm |
| PH calibration approval range | Zero +/- 1.45 pH; slope +/- 30% |
| PH standard solution | 4.01/6.86/9.18;4.00/7.00/10.01 |
| ORP standard solution | Any standard solution |
| control range | 0-14.00 pH、-1999+1250 mV |
| Output signal | 4~ 20mA isolation protection output |
| Control output mode | ON/OFF relay output contact |
| The relay bears the load | Maximum AC 230V 5A; Maximum AC 115V 10A |
| Relay hysteresis | Can be adjusted freely |
| Current output load | The maximum allowable load is 500W. |
| Voltage insulation to ground | The minimum load is 500VDC. |
| Signal Input Impedance | ≥1*1012W |
| Operating Voltage | 230VAC±15%、50/60Hz |
| opening size | 1/4DIN |
| mV measurement Accuracy | ±0.1%F.S |
| mV range | 1999~1500mV |
AOLILONG PHG-2 Industrial online pH Meter Packing list
Host x1, electrode x1, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Definition, working principle and structure introduction of industrial pH meter
- How to use pH meter, maintenance measures and methods of Troubleshooting
- Glass electrode of pH acidity meter should be selected correctly
- What are the common classifications of industrial pH meter electrodes?
- Detection principle of pH value
- Differences between several common water quality testing equipment
- Acidity meter operation instructions
- Pigment pH value determination
- Maintenance technology of acidity meter (detailed introduction)
- Uncertainty measurement experiment introduced by different levels of pHmeter
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveGB/T 35464-2017
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005


PHG-2