      Home> Color difference meter> 3NH> 3NH NR145 Colorimeter

      3NH NR145 handheld Colorimeter measurement aperture 8mm vertical lightweight design ≤ 0.08Delta E * ab error value

      8Mm measurement diameter, automatic black and white correction when turned on; light + cross frame dual positioning; using three core technologies of super light path, dynamic integration and measurement timing.

      Brand
      SKU: NB000739
      China 3NH
      Model
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • 3NH NR145 ColorimeterOverview

        • Specifications
        • Comments
        • FAQs
        NR145
        Colorimeter
        • 3NH NR145 handheld Colorimeter measurement aperture 8mm vertical lightweight design ≤ 0.08Delta E * ab error value
        • 3NH NR145 handheld Colorimeter measurement aperture 8mm vertical lightweight design ≤ 0.08Delta E * ab error value Figure 1
        • 3NH NR145 handheld Colorimeter measurement aperture 8mm vertical lightweight design ≤ 0.08Delta E * ab error value Figure 2
        8Mm measurement diameter, automatic black and white correction when turned on; light + cross frame dual positioning; using three core technologies of super light path, dynamic integration and measurement timing.

        product description

        Sannchi NR145 Handheld Colorimeter is a white plastic shell. In terms of structural design, it is a vertical structure. The test button is designed on the back of the Colorimeter. The front of the Colorimeter is a large LCD, and there are five operation buttons on the left. . The overall structural design of the NR145 handheld Colorimeter is well combined with ergonomics, and the handheld product is more suitable for measuring small areas, and it is not easy to stain the body.

        Sannchi NR145 handheld Colorimeter is very good in any industry. The error value of ≤0.08ΔE*ab allows you to measure every time within the standard range. NR145 handheld Colorimeter makes the measurement highly anticipated. Elaborate research and development, professional production, compact shape, precision workmanship, NR145 portable Colorimeter is perfect and impeccable.

        The 3nh R&D team is fully committed to various fields required by customers. In the color detection industry, it is committed to continuously developing a full range of high-quality, cost-effective products. After NR20XE, the high cost-effective 45°/0° handheld Colorimeter was launched, which has powerful functions and applied a number of differentiated innovative technologies to meet users' accurate measurement of 45° illumination/0° reception in SCE mode.

        Features

        Sannchi NR145 handheld Colorimeter has built-in whiteboard parameters, no need for each calibration, to achieve fast start-up measurement;

        ●Double positioning: the innovative patent of light positioning and the precise positioning of the cross structure

        Sannchi NR145 handheld Colorimeter uses the three core technologies of super optical path, dynamic integration and measurement sequence, which greatly improves the stability and accuracy of measurement;

        ●45°/0° optical geometric structure, the measured result is more consistent with the visual effect

        ●8mm measuring aperture, vertical and lightweight design, suitable for more measuring occasions.

        Precautions for use

        1) When the battery power is lower than 30%, it is best to change the battery or charge it. Hand-held Colorimeters now use large-capacity lithium batteries, which can be recycled, which is environmentally friendly and resource-saving. When the battery is less than 30%, it is good to charge it in time, but remember to turn off the machine when charging, which can not only prolong the life of the battery , but also a maintenance of the machine itself.

        2) After the product is produced, do not detect it immediately and leave it for 3-4 hours. Wait until the product temperature reaches a constant value and then use a portable Colorimeter to detect the color difference. In 3-4 hours, the temperature of the general product will drop to a constant temperature similar to the room temperature, but it is not ruled out that there are some special products that dissipate heat slowly or are not easy to cool down. It is necessary to determine a period of time according to the actual situation to make the product temperature reach constant. Then use a portable Colorimeter to test.

        3) The average measurement mode is used for parts with complex shapes, and the accuracy of the collected data is higher. Because the surface of parts with complex shapes is generally not very smooth, portable Colorimeters generally have the function of multi-point measurement and averaging, which is more reliable when used on parts with complex shapes.

        4) Fixed measurement personnel, standardized requirements for measurement locations and measurement directions. The pressure trigger switch of the portable Colorimeter is used by different people, and the trigger pressure is different, which also has a certain impact on the data, and this factor will not lead to the judgment of the result.

        5) If there is a problem with the accuracy of the handheld Colorimeter, it must be returned to the factory for repair. It is recommended to perform manual black-and-white calibration at least once a week, or perform black-and-white calibration when the measurement data of the portable Colorimeter is inaccurate. Portable Colorimeters will produce measurement errors after being used for a period of time.

        Pictures

        Sannchi NR145 Handheld Colorimeter Display


        Detail diagram of measurement aperture of Sannchi NR145 handheld Colorimeter


        The back view of Sannchi NR145 Handheld Colorimeter

        VS

        3NH NR145 ColorimeterSpecifications

        LIST VALUE
        Lighting method 45°/0°
        lighting source LED light source
        sensor Silicon photodiode
        Measurement caliber F8mm
        Color space CIE LAB, XYZ, LCh
        Color difference formula ΔE * from
        Other chromaticity indicators /
        Viewing Angle CIE 10 °
        Measurement light source D65
        display mode Chromatic value, color difference value/graph, pass/fail result, Color bias
        Measurement time 1.5s
        Sexual repeability Φ8mm / ΔE * from 0.08<--sep--0/>
        Inter-station difference ΔE * from < 0.4
        Dimensions 205*67*80mm
        Weight 400g
        Battery life Rechargeable Li-Ion Battery 3.7V @3200mAh
        Lighting source life 5 years more than 1.60 million measurements
        Display TFT True Color 2.8inch @(16:9)
        Data Interface USB
        Data storage 100 master standards, 20,000 samples
        Operating conditions 0~40℃(32~104°F)
        Storage environment -20~50℃
        PC software CQCS3 high-end quality management software
        Optional accessories Micro printer, powder test box
        Standards CIE No.15GB / T 3978

        3NH NR145 Colorimeter Packing list

        Host x1, Manual x1, Certificate of conformity and warranty x1, Encasement box x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How long is the measurement response time of this NR145 color reader?
        [A]
        Hello, about 1.5s.
        [Q]
        What is the measurement aperture of this NR145 color reader?
        [A]
        Hello, the measurement aperture of this NR145 handheld color reader is φ 8mm.
        [Q]
        How many sets of data can this NR145 handheld color reader store?
        [A]
        Hello, this color reader can store 100 standards and 20,000 samples.
        [Q]
        Do you have the color reader required by the GB/T15608 standard?
        [A]
        This NR145 color reader will do.
        [Q]
        What are the regulations and requirements for the use of color readers?
        [A]
        General color readers are equipped with detailed trial instructions. If you lose it, please contact the seller.
        +3NH NR145 Colorimeter Big data
          +3NH NR145 ColorimeterSimilar products
          +3NH NR145 ColorimeterKnowledge
          +3NH NR145 ColorimeterStandard
          +Navigation
          3NH
          3NH NR145 handheld Colorimeter measurement aperture 8mm vertical lightweight design ≤ 0.08Delta E * ab error value
          Service
          Focus on online sales of Lab Testing Instruments