Mattel MT150 Ultrasonic Thickness Gauge Thickness Range 0.75~ 300mm Resolution 0.1mm
Mattel MT150 Ultrasonic Thickness Gauge is a split type Ultrasonic Thickness Gauge, the thickness range is 0.75~ 300mm, MT150 Ultrasonic Thickness Gauge for metal, plastic, Ceramics, Glass and Miscellaneous a variety of ultrasonic good conductor material Film thickness measurement.
mitech-
IPRE UT150 Ultrasonic Thickness Gauge measurement range 1~ 225mm
$ 234.00 -
Linshang LS212 Professional Ultrasonic Thickness Gauge Thickness Measurement 0.8~ 350mm
$ 273.00 -
Defelsko C Advanced 2003-E Ultrasonic Coating Thickness Gauge Coating thickness of concrete, fiberglass, etc
$ 3509.00 -
AMITTARI AT-140B high-precision Ultrasonic Thickness Gauge resolution 0.01 Measurement range 1-300mm
$ 459.00 -
D2012 (concave surface) Ultrasonic Thickness Gauge Probe
$ 273.00
product description
Mitech MT150 Ultrasonic Thickness Gauge, based on the principle of ultrasonic measurement, can measure the thickness of metals, plastics, ceramics, glass and other materials that are good conductors of ultrasonic waves, and can also realize the reverse measurement of the sound velocity of materials. Compared with the traditional measurement method, the advantage of the ultrasonic Thickness Gauge is that it can complete the measurement as long as it touches one side of the workpiece to be measured. It is a good solution and is widely used in the monitoring of the corrosion and thinning degree of various pipelines and pressure vessels in production equipment in the fields of petroleum, chemical industry, metallurgy, shipbuilding, aviation, aerospace, etc., and can also be used to monitor various plates and various Machined parts for precise measurements.












functional use
Suitable for measuring the thickness of metals (such as steel, cast iron, aluminum, copper, etc.), plastics, ceramics, glass, glass fibers and any other good conductors of ultrasonic waves. It can be equipped with a variety of dual-crystal probes with different frequencies and different chip sizes. It has a zero point of the probe. Calibration and two-point calibration function can automatically correct the system error The known thickness can reverse the sound velocity to improve the measurement accuracy It has a coupling status prompt function and an EL backlight display, which is convenient for use in a dimly lit environment. Real-time display of the remaining battery power with automatic sleep, automatic shutdown and other power-saving functions Compact, portable, high reliability, suitable for harsh operating environments, anti-vibration, shock and electromagnetic interference
Operating Conditions
Ambient temperature: operating temperature -20℃~+50℃
Storage temperature: -30℃~+70℃
Relative Humidity≤90%
The surrounding environment has no strong vibration, no strong magnetic field, no corrosive medium and severe dust
Features
Suitable for measuring the thickness of metals (such as steel, cast iron, aluminum, copper, etc.), plastics, ceramics, glass, glass fibers and any other good conductors of ultrasonic waves
Can be used with a variety of dual-element probes with different frequencies and different chip sizes
With probe zero calibration and two-point calibration functions, it can automatically repair system errors
The known thickness can reverse the sound velocity to improve the measurement accuracy
With coupling status prompt function
With EL backlight function, it is convenient to use in dimly lit environment
There is a remaining power indicator function, which can display the remaining battery power in real time
Power-saving functions such as automatic sleep and automatic shutdown
Small, portable, high reliability, suitable for harsh operating environments, resistant to vibration, shock and electromagnetic interference
mitech MT150 Ultrasonic Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0.75~300mm |
| Probe frequency | 2.5~7MHz |
| Probe style | With wire probe |
| Probe diameter | Thickness probe NO5Φ10MM, microcrystalline probe N07Φ6MM, high temperature probe HT5Φ12MM, coarse crystal probe N02Φ12MM |
| Lower limit of pipe measurement | F15 * 2mm |
| Measurement error | ±(1%H+0.1)mm |
| Display resolution | 0.1mm |
| unit system | mm/inch |
| Calibrated | Zero point calibrated, two point calibrated |
| Measurement mode | Single point mode, scan mode |
| Sexual repeability | ± (1% H + 0.1) mm; H is the actual film thickness of the measured object |
| Storage Capacity | 20 sets * 100 measurements |
| Sound speed range | 1000~9999m/s |
| Sound speed storage | 4 times per second for single point measurement and 10 times per second for scan mode |
| Display | High contrast segment LCD display, high brightness EL backlight |
| Operating language | Chinese |
| Data Interface | without |
| Application software | without |
| Operating Temperature | -20~50℃ |
| Relative Humidity | ≤90%RH |
| Storage temperature | -30~70℃ |
| Power | 3V (2 * AA alkalinity battery) |
| power consumption | Low power design |
| Operating Time | 100h |
| Host size | 150*74*32mm |
| Weight | 1.3KG |
| Body material | ABS engineering plastics |
mitech MT150 Ultrasonic Thickness Gauge Packing list
Instrument host x1, manual x1, coupling agent x1, AA (No. 5) battery x2, instrument case x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1224-2009
- ActiveJJF 1126-2004
- ActiveJB/T 11604-2013
- ASTM E797-2021
- AbolishGB/T 11344-2008
- JJF 1126-2004
- AbolishZB N 77001-1989