Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Ultrasonic Thickness Gauge> LUKE> LUKE LK300 Ultrasonic Thickness Gauge

      LUKE LK300 Ultrasonic Thickness Gauge Measurement range 0.75~ 300mm

      LUKE LK300 Ultrasonic Thickness Gauge is a split Ultrasonic Thickness Gauge. Measurement range is 0.75~ 300mm. LK300 has two thickness measurement modes: single-point thickness measurement and scanning thickness measurement.

      Brand
      SKU: NB007631
      China LUKE
      Model
      VS
      LUKELOGO

      LUKE

      Information
      Genuinegoods
      • LUKE LK300 Ultrasonic Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      LK300
      Ultrasonic Thickness Gauge

      overview

      Luke LK300 ultrasonic Thickness Gauge is an intelligent ultrasonic Thickness Gauge based on the principle of ultrasonic measurement, using new high-performance, low-power microprocessor technology, which can measure the thickness of metals and other materials, and can measure the ultrasonic sound velocity of materials. In addition, the instrument can monitor various pipes and pressure vessels in production equipment, monitor their degree of thinning after corrosion during use, and can also accurately measure various plates and various machined parts. This instrument can be widely used in petroleum, chemical industry, metallurgy, shipbuilding, aviation, aerospace and other fields.

      Luco Inspection LK300 Ultrasonic Thickness Gauge

      Features

      1. It is suitable for measuring the thickness of metals (such as steel, cast iron, aluminum, copper, etc.), plastics, ceramics, glass, glass fibers and any other good conductors of ultrasonic;

      2It can be equipped with a variety of dual element probes with different frequencies and different element sizes;

      3It has the functions of zero point calibration and two-point calibration of the probe, which can automatically correct the system error;

      4Known thickness can be used to measure the sound velocity back, so as to improve the measurement accuracy;

      5It has the function of coupling status prompt;

      6There is EL backlight display, which is convenient to use in dimly lit environments;

      7There is a residual power indication function, which can display the remaining battery power in real time;

      8It has power-saving functions such as automatic sleep and automatic shutdown;

      9With RS232 interface, it can easily and quickly exchange data with the PC, and can be connected to the micro printer (manufacturer-specified model) to print the measurement report;

      10It can be equipped with microcomputer software, which has rich functions such as transmitting measurement results, measuring value storage management, measuring statistical analysis, printing measurement report, etc.;

      11Small, portable, high reliability, suitable for harsh operating environments, resistant to vibration, shock and electromagnetic interference;

      Instrument configuration and probe selection

      Table 1.1 Instrument configuration


      serial number

      name

      quantity

      remark

       

       

       

       

      Standard configuration

      1

      host

      1 unit


      2

      Standard Probe (BT-08)

      1 pc


      3

      Couplant

      1 bottle


      4

      Instrument case

      1 pc


      5

      Instruction manual

      1 serving


      6

      AA (size 5) alkaline batteries

      2 pcs


       

       

       

       

      Optional

      7

      Coarse Grain Probe(ZT-12)



      8

      Small Diameter Tube Probe (XT-06)



      9

      High Temperature Probe (GT-350)



      10

      Micro printers

      1 unit

      Applied on the computer

      11

      Print the cable

      1 article

      12

      Data management software

      1 set

      13

      Communication cables

      1 article

      Table 1.2 Probe Selection

      name

      Model

      Frequency

      (MHZ)

      Probes

      Straight diameter

      Measuring range

      Minimum pipe diameter

      Description

      Coarse-grain probes

      ZT-12

      2

      12mm

      3.0mm~300.0mm(Steel)

      Φ20mm

      It is used for measuring coarse-grained materials such as cast iron

      Standard probes

      BT-08

      5

      8mm

      1.0mm~230.0mm(Steel)

      Φ20mm×3.0mm

      general

      Small-diameter tube probes

      XT-06

      7.5

      6mm

      0.75mm~80.0mm(Steel)

      Φ15mm×2.0mm

      It is used for the measurement of thin-walled and small-cambered pipes

      High temperature probes

      GT-350

      5

      14mm

      3~200mm(Steel)

      Φ30mm

      It is used for the measurement of materials with temperatures less than 350°C

      VS

      LUKE LK300 Ultrasonic Thickness GaugeSpecifications

      LIST VALUE
      Measurement range 0.63~ 500Mm (steel, depending on probe)
      Probe Frequency 1MHz~10MHz
      Calibration method Dialog Probe, Automatic calibration
      Speed of sound 1250~10000m/s
      Display LCD display with backlight
      Power Supply 2 AA batteries. The continuous use time is up to 200 hours. When the battery power is insufficient, the display will flash an alarm until it automatically shuts down.
      Display Accuracy 0.01mm
      scanning method 16 points per second measurement, can capture the thinnest point

      LUKE LK300 Ultrasonic Thickness Gauge Packing list

      Machine X1, standard probe (BT-08) X1, coupling agent X1, instrument case X1, AA (No. 5) size alkaline battery X2, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Excuse me, why is my LK300 Ultrasonic Thickness Gauge measurement error a bit big?
      [A]
      Hello, you can check first: a) Whether the sound speed setting is correct. b) Calibrate. c) There may be pinholes, pores and other defects inside the tested material. If there is no problem, you need to return to the factory for repair.
      [Q]
      How thin can this LK300 Ultrasonic Thickness Gauge measure?
      [A]
      LK300 Ultrasonic Thickness Gauge can measure the minimum thickness of 0.63mm
      [Q]
      Find an Ultrasonic Thickness Gauge for JJF1126
      [A]
      This is the LK300 Ultrasonic Thickness Gauge.
      LUKE
      LUKE LK300 Ultrasonic Thickness Gauge Measurement range 0.75~ 300mm
      Service